Jul 13, 2026 10 demerits · 3 violations
Inspector comments: Inspection conducted with CPO Jenny Brink.
Observed pre-permit items from previous inspection have been corrected.
Facility has until February 28th, 2027 to correct noted issues with gates and door to restrooms.
Can contact Will Harrison (704) 507-6824 to schedule inspection once issues have been corrected.
Permit issued with the following conditions:
No night swimming
Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir installed upside down. .2518(k) Provide functional weirs. - Corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Service gates missing self-latching mechanism. .2528(a) All gates other than pedestrian access gates shall have a self-latching device. - Will need to correct by 2-28-2027.
Gate at bathrooms does not meet requirements. Door to bathrooms not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Will need to correct by 2-28-2027.
Gates with gaps > 2” under gate. .2528(a) Maintain 2" or less under gates. - Will need to correct by 2-28-2027.
Main gate with decorative cutouts and footholds. .2528(a) Where barrier consists of both horizontals and vertical members and horizontals are less than 45" apart, the horizontal member shall be located on the inside of the barrier with openings between vertical members no greater than 1.75 inches. - Will need to correct by 2-28-2027.
Decorative cutouts in pre-2010 fencing. .2528(b) Maintain between 30 to 45 inches between bottom horizontal member and the next horizontal member (pre May 1, 2010).
Pre-2010 fence with gaps > 4” under the fence. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 1, 2010).
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash plumbed directly into pump room floor. .2513(b) Filter backwash shall be discharged through an air gap.
Jul 9, 2026 28 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Jenny Brink.
Facility went through in-field plan review. Changed pool profile to reduce to 4’6” in the deep end. Removed carpet and resurfaced pool deck.
Conducted pre-permit operational inspection
Pre-permit inspection did not pass.
2)
8)
10)
15)
24)
Prior to scheduling a re-inspection. Will need to pay a $100 re-inspection fee by calling our office (980) 314-1620.
#2 · Water quality: disinfectant residual provided by −6
0.1ppm free chlorine in the pool .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. - Pre-permit item.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer equalizer lines not plugged in the skimmer. .2518(k) Skimmer equalizer lines shall be in compliance with ANSI/PHTA/ICC-7 or disabled. - Pre-permit item.
Missing one of two weirs. .2518(k) Provide functional weirs. - Pre-permit item.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Breakpoint rope < 3/4” in diameter. .2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. - Pre-permit item.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook with only one screw attaching it to the pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Pre-permit item.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Service gates missing self-latching mechanism. .2528(a) All gates other than pedestrian access gates shall have a self-latching device. - Will follow up with facility.
Gate at bathrooms does not meet requirements. Door to bathrooms not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Will follow up with facility.
Gates with gaps > 2” under gate. .2528(a) Maintain 2" or less under gates. - Will follow up with facility.
Main gate with decorative cutouts and footholds. .2528(a) Where barrier consists of both horizontals and vertical members and horizontals are less than 45" apart, the horizontal member shall be located on the inside of the barrier with openings between vertical members no greater than 1.75 inches. - Will follow up with facility.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. .2518(g) Keep the flow meter operational. - Pre-permit item.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash plumbed directly into pump room floor. .2513(b) Filter backwash shall be discharged through an air gap.
Jun 18, 2025 16 demerits · 4 violations
Inspector comments: NO NIGHT SWIMMING.
CARPET MUST BE REMOVED PRIOR 2026 OPERATING SEASON.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed paint on pool wall starting to peel. EHS observed peeling paint not hazardous to public at time of inspection. Pool may need to be re-painted in the future. EHS contacted supervision during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope longer than the required length. CPO cut ring buoy rope to required length during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed deck covered in carpet which does not meet code. Observed carpet sticking up more than an inch. CPO was able to secure carpet back to deck. CARPET MUST BE REMOVED PRIOR TO 2026 OPERATING SEASON. EHS contacted supervision during inspection.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool. Observed no shower sign. CPO posted sign during inspection
Jul 9, 2024 0 demerits · 0 violations
Inspector comments: No violations were observed during the inspection.
No violations were recorded for this inspection.
May 22, 2023 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 7.0. Maintain pH at 7.2 to 7.8. CDI - pH was raised to 7.2 by end of inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Plaster damage near skimmer basket near deep end. Re-plaster to prevent trip hazard.
Jun 2, 2022 12 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
throw rope was corrected to 41ft
#22 · Premises: emergency telephone provided −6
phone was not working but new phone was placed in box and working correctly.
May 26, 2021 2 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Jenny.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. No proof of shatterproof mirrors.
May 27, 2020 0 demerits · 0 violations
No violations were recorded for this inspection.
Jun 5, 2019 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed gap near far side of pool deck at the 9ft. depth marker. -4-
May 23, 2018 8 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder was observed to be loose. Tighten ladder
#22 · Premises: emergency telephone provided −6
Address was not posted at emergency phone. CDI posted address inside emergency phone.
Jun 8, 2017 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 - Ladders and handrails shall be installed where required and maintained in good repair. One ladder loose. Tighten.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513 - Backwash shall be discharged through an air gap. Backwash directly plumbed to drain.
May 27, 2016 0 demerits · 0 violations
Inspector comments: Pump is a Hayword Super Pump II SP3015EEAZ 2.5HP
No violations were recorded for this inspection.
Jun 22, 2015 8 demerits · 3 violations
Inspector comments: #15 General Comment: Switch ring buoy proir to 2016 season.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Need to add depth marker (9') to deep end of pool on pool wall.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
ensure that all ladders and handrails are tinght and secure.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump and chemicals are stored together in same room.
Jun 6, 2014 10 demerits · 3 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth markers properly located and sized but need darkened. They are readable.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. CDI
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors must be shatterproof. Mirrors are glass.