01020 Jun 18, 2015: 0Jun 30, 2016: 20Jul 6, 2017: 4Jun 15, 2018: 4May 23, 2019: 8Jun 4, 2020: 6Jun 4, 2021: 6Apr 21, 2022: 20Apr 27, 2023: 2May 22, 2024: 0Jun 24, 2025: 6Jun 5, 2026: 4
Jun 18, 2015Lower is betterJun 5, 2026

Inspections & violations

Jun 5, 2026 4 demerits · 1 violation
Inspector comments: Expiring/expired covers requires replacement prior to permit 2026. Main drain and equalizers replaced new PDSC form received and approved proceeded with inspection for 2026 swimming season. Permit restrictions: flow meter must remain operable flow required at 69 gallons per minute to 74 gallons per minute to meet turnover and flow restriction of the filter flow greater than 170 gallons per minute is a suction hazard for main drains and equalizers. Flow measured at 75 gallons per minute.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. observed some debris on pool floor.

View this inspection on the county portal ›

Jun 24, 2025 6 demerits · 1 violation
Inspector comments: Permit Restriction: Flow meter must remain operable. Flow required at 69 gpm to 74 gpm to meet turnover and flow restriction of the filter. New pump verified during inspection. Pump identified as a Hayward TristarVS 950, SP32950VSP, 2.7 HP. Flow meter read within the required range (70 gpm) Main drains verified as (2) Aquastar A10RCFRxxx 2008 drain covers. Night swimming not permitted.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy at 50ft. Rope cut to proper length (30 ft) during inspection.

View this inspection on the county portal ›

May 22, 2024 0 demerits · 0 violations
Inspector comments: No violations noted at time of inspection. Permit and sticker were issued at time of inspection. Pool may begin operation at owner’s discretion.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 27, 2023 2 demerits · 1 violation
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments. Restroom door is locked and lock is broken and is hanging loose from door. Pool operator stated there is no plans for having door lock repaired to make restrooms accessible. Repair door lock to provide a sink and toilet for residents and guests.

View this inspection on the county portal ›

Apr 21, 2022 20 demerits · 6 violations
Inspector comments: Night swimming is not permitted. PDSC verified.
#3 · Water quality: pool water pH −6
Observed pool with a pH of 7.0 initially. CDI pool pH raised to 7.4 during the inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Pool debris observed on the pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers with noticeable amounts of debris present during the inspection.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Observed safety rope with colored floats at a greater distance than 5 feet apart. Floats were moved to maintain 5 feet or less distance apart.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Observed ladders at a greater distance than 6 inches from the wall during the inspection. .2521 Install ladders per manufacturer instructions. Observed ladder with second step not operable. CDI CPO repaired during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemicals stored on the floor during the inspection.

View this inspection on the county portal ›

Jun 4, 2021 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length longer than 30 feet. Rope was cut during the inspection. **.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.

View this inspection on the county portal ›

Jun 4, 2020 6 demerits · 2 violations
Inspector comments: Night Swimming has not been permitted. Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed staining on the pool walls. Needs cleaning or repainting.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed loose ladder to the deep end. The operator was able to repair the loose ladder.

View this inspection on the county portal ›

May 23, 2019 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing or damaged skimmer basket. Observed damaged skimmer basket.

View this inspection on the county portal ›

Jun 15, 2018 4 demerits · 2 violations
Inspector comments: Next year, black step treads need to be painted to the side of the pool. Note: Gate opens toward the pool due to egress space. PDSC form verified.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. No cross ventilation.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(m) Keep restrooms and fixtures clean and in good repair. One urinal is out of order.

View this inspection on the county portal ›

Jul 6, 2017 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed two sections of the fence with greater than 4" between the vertical rail and the brick columns on the section nearest the tennis court. Fence was built prior to 2010. -4-

View this inspection on the county portal ›

Jun 30, 2016 20 demerits · 5 violations
Inspector comments: .2518 Keep skimmers baskets clean and in good repair. Observed skimmer baskets with debris. Inspection conducted with Jack Parks
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539 Proper documentation of drain covers shall be submitted. Observed paramount covers on equalizers and not Aquastar A10RCFRxxx and Hayward pump that was 1.5 HP and not .5 HP as stated on PDSC form. Immediate suspension issued unitl approval given.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Pool walls and floors shall be kept clean and in good repair. Observed pool walls near surface where it was heavily cracked and portions of the wall is peeling away.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528 Gates must swing away from the pool unless natural topagraphy, landscape position, or emergency egress prevent gates from doing so. Observed gates that did not swing away from the pool.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537 Keep pool decks unobstructed and free of trip hazards. Observed wide spacing and cracks on pool deck.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534 Provide form of ventialtion in chemical room. Observed equipment/chemical room with no form of ventilation.

View this inspection on the county portal ›

Jun 18, 2015 0 demerits · 0 violations
Inspector comments: All pre-inspection items corrected. Permit to be issued.

No violations were recorded for this inspection.