‹ Back to search

22demerits

ARBORGATE APARTMENTS

9056 ARBORGATE DR, Charlotte, NC 28273
Seasonal Swimming Pool · NC permit/State ID 2060500025
Latest result22 demerits
Last inspectedMay 29, 2026
Inspections on record15
On record sinceJun 9, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01326 Jun 9, 2014: 26May 20, 2015: 8May 25, 2016: 6Jul 21, 2017: 12Jun 13, 2018: 10May 24, 2019: 4Jun 4, 2020: 12Jun 24, 2021: 0Jun 30, 2022: 6Apr 26, 2023: 6May 12, 2023: 0Apr 10, 2024: 6Jul 15, 2024: 4Jun 4, 2025: 24May 29, 2026: 22
Jun 9, 2014Lower is betterMay 29, 2026

Inspections & violations

May 29, 2026 22 demerits · 6 violations
Inspector comments: Information on PDSC forms and the following permit restrictions verified during today’s inspection: Flow meter must remain operable. Flow shall not exceed 119 gob due to drain cover flow restriction. Suction Hazard. Priority items observed were corrected during today’s inspection by CPO Jose Perozo. Permit issued. Not permitted for night swimming.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed ladder with no slip resistant tread. .2521(b)(3)(A) Handrails, if removable, shall be installed in such a way than they cannot be removed without the use of tools. Observed two loose handrails at steps of pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Initially observed ring buoy rope at length of 32’. CDI - CPO cut rope length to permit specific length of 30’.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed trip hazards under hand rail at 3ft, edge of pool at 5 ft and surrounding 1 skimmer all measuring > 1/2”. CDI - CPO repaired areas during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone operable, but with improper telephone number on posted signage. CDI - Phone number was verified with emergency services during verification call and improper phone number was covered using available tape by CPO; new phone number was written over it.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed opened bag of pH Down (sodium bisulfate) stored on the floor in chemical storage room. CDI - Chemical removed off floor. .2533(d) Pump room floor shall be kept dry and free of standing water. Observed water pooling on floor due to water leak from automatic chlorine/bromine feeder.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap in restroom. Provide.

View this inspection on the county portal ›

Jun 4, 2025 24 demerits · 5 violations
Inspector comments: PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW MAXIMUM AT 119 GPM DUE TO DRAIN COVER FLOW RESTRICTION. CHANGED TO SUMPLESS COVER 2/2018
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed uncovered vacuum suction line within pool at start of inspection. Observed one (1) return outlet with no fitting. CDI - CPO retrieved proper fittings from pool supply room during inspection. Eyeball fitting was installed for return outlet, and approved protective cover for vacuum line was screwed into place and secured (Pool constructed prior to May 1, 2010.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. Observed ladder with no slip resistant tread. .2521(b)(3)(A) Handrails, if removable, shall be installed in such a way than they cannot be removed without the use of tools. Observed one (1) loose handrail at steps of pool. CPO sealed loose handrail at deck using concrete at time of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Initially observed ring buoy rope at length of 33’. CDI - CPO cut rope length to permit specific length of 30’
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone operable, but with improper telephone number on posted signage. CDI - Phone number was verified with emergency services during calls and improper phone number was covered using available tape by CPO; new phone number was written over it.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare basket for pump.

View this inspection on the county portal ›

Jul 15, 2024 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed self closing gate to pool not self latching. Operator corrected issue during inspection and gate was fully self latching.

View this inspection on the county portal ›

Apr 10, 2024 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone inoperable.

View this inspection on the county portal ›

May 12, 2023 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 26, 2023 6 demerits · 1 violation
Inspector comments: Flow meter was reading 95 gpm during inspection. Max flow on PDSC form is 85 gpm. Max flow of drain covers is 119 gpm. Department will notate flow restriction on field guide.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. EHS test chlorine level of pool and PPM was 0.0. Ensure at least 1.0PPM of chlorine residual is present in pool.

View this inspection on the county portal ›

Jun 30, 2022 6 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed pool records need column added for checking main drains and emergency equipment
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. .2526(l) Provide toilet paper and dispensers in restrooms. .2526(m) Keep restrooms and fixtures clean and in good repair. Observed bathroom needed cleaning, soap and toilet paper.

View this inspection on the county portal ›

Jun 24, 2021 0 demerits · 0 violations
Inspector comments: POOL PASSED INSPECTION Inspection conducted with Lorena Perez

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 4, 2020 12 demerits · 4 violations
Inspector comments: No night swimming permitted.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed distance of fencing measuring greater than 4in. in areas on parameter of pool. Pool built prior to 2010 and some vertices measuring 4 1/4"
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Lawn chairs were obstructing deck and not allowing 6 feet of clearance. CDI. Chairs moved.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. No disposable towels provided.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. No backflow prevention device on hose bib near restroom.

View this inspection on the county portal ›

May 24, 2019 4 demerits · 1 violation
Inspector comments: NIGHT SWIMMINNG NOT PERMITTED.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Lawn chairs were obstructing deck and not allowing 6 feet of clearance. CORRECTED. Chairs moved.

View this inspection on the county portal ›

Jun 13, 2018 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. .253. Throw rope for ring buoy more than 2 feet too long. CDI- rope corrected.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(c) New fencing installed must be in compliance with .2528 Fences. Distance from ground to rung under newly constructed fencing greater that 2". Measurement of 11" to 12" in some places around three of four sides of fencing. CDI- CPO began correction. Property manager also called for delivery of more ground cover.

View this inspection on the county portal ›

Jul 21, 2017 12 demerits · 3 violations
Inspector comments: Entry gate swings inward. GENERAL COMMENTS: # 8- One of four weirs missing in skimmer baskets. Operator advised he has another one and will replace it. # 21- Pool hours are posted as 10a- 9p. Operator was not able to locate manual switch to turn on lights at pool. Operator advised that lights are on day cells, and no night swimming is allowed.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Lounging chairs on pool deck obstructing the required 6FT clearance. Cracked caulking and small pitted areas at pool deck. Allow for 6FT clearance and repair pool deck. Operator advised he will correct.
#22 · Premises: emergency telephone provided −6
Both phone numbers of 704-527-2184 and 704-525-8092 posted at emergency phone. The 8092 number is the correct number. Operator corrected.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Operator advised that restroom still need to be cleaned more. No papertowels and toilet paper provided in restroom. Provide papertowels and toilet paper.

View this inspection on the county portal ›

May 25, 2016 6 demerits · 2 violations
Inspector comments: Verified PDSDC form is correct and submitted to MCHD (Will Harrison) NOTE: Backwash discharges to street behind pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one (1) weir in skimmer. Replace
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Provide vacuum breaker (backflow preventer on all hose bibs.

View this inspection on the county portal ›

May 20, 2015 8 demerits · 3 violations
Inspector comments: #7 Pool floor chipped in some areas. ** Correct next time pool is drained or problem gets worse. #16 Outside approach to wooden section of pool barrier 45" in height. ** Barrier should be at least 48". Note: backwash water discharges to curb; hence, air gap present. POOL PERMIT CANNOT BE ISSUED until new main drain covers installed & new PDSC form approved.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Coping & deck chipped in areas. ** Repair. Deck lounge chairs ~5' - 5 1/2' from pool edge. ** Keep chairs as far as possible from pool edge. There should be 6' of clear walking space. (narrow deck)
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No cross or forced air ventilation in equipment/ chemical room. ** Provide.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Shower drain missing grate. ** Correct/ install. Mirror in restroom not shatterproof. ** Mirror should be made of shatterprrof materials.

View this inspection on the county portal ›

Jun 9, 2014 26 demerits · 6 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed cracked skimmer cover. Equalizer line covers protrude greater than 2 inches. ITS issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope for ring buoy more than 30 feet. CDI cut to length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate opens towards pool (due to topography).
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck with offset greater than 1/2 inch. ITS issued
#22 · Premises: emergency telephone provided −6
Observed wrong phone number for emergency phone posted. CDI
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no soap in bathroom.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ARBORGATE APARTMENTS” or State ID 2060500025). Inspection type (routine vs. follow-up) is not published in the county's data.