‹ Back to search

0demerits

ASHBROOK CONDOMINIUMS

3722 PARK RD, Charlotte, NC 28209
Seasonal Swimming Pool · NC permit/State ID 2060500032
Latest result0 demerits
Last inspectedMay 21, 2026
Inspections on record13
On record sinceJun 2, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01224 Jun 2, 2014: 4Apr 15, 2015: 12Apr 15, 2016: 8May 17, 2017: 0Apr 11, 2018: 8Apr 18, 2019: 22Apr 16, 2020: 20Apr 23, 2021: 0May 31, 2022: 8May 4, 2023: 24May 15, 2024: 10Jul 28, 2025: 8May 21, 2026: 0
Jun 2, 2014Lower is betterMay 21, 2026

Inspections & violations

May 21, 2026 0 demerits · 0 violations
Inspector comments: Pool is open for the 2026 season. No night swimming. No permit restrictions

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 28, 2025 8 demerits · 3 violations
Inspector comments: New ring buoy and rope supplied during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Pool Floor dirty - Vacuum
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.- No air gap on backwash line
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - No backflow preventer on spigot.

View this inspection on the county portal ›

May 15, 2024 10 demerits · 2 violations
Inspector comments: Replace flow meter due to numbers fading. Not easily readable.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight debris on pool floor.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy rope length longer than 30’. -CDI- CPO corrected.

View this inspection on the county portal ›

May 4, 2023 24 demerits · 6 violations
Inspector comments: Pool does not plan to have night swimming. Pool will close at 8pm. Night swimming is prohibited.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine level at 0.8ppm. Corrected to 1.5 ppm.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH @ 8.4+. Corrected to 7.5.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Repeat: .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed floating debris and leaves in skimmer baskets when checked. Cleaned.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed piles of leaves on pool deck on parking lot side that needs to be cleaned. Cleaning in progress.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap in men’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. Observed light in women’s restroom not working. Bulb was replaced.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed hose bib on deck missing back flow preventer. Provided by CPO.

View this inspection on the county portal ›

May 31, 2022 8 demerits · 3 violations
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
no breakpoint rope at the 4' to 6' transition. Grandfathered from 1984 construction
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
slight cracks on the pool deck must be addressed before they progress into a trip hazard. Currently not a trip issue but should be monitored
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
mirrors in bathroom are not shatterproof

View this inspection on the county portal ›

Apr 23, 2021 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 16, 2020 20 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed floating debris located on pool walls and pool floors.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed floating debris in skimmers when checked.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed Ring buoy greater than 30ft. CPO adjusted rope so that it is 30ft which is required according to facility's PMDS data sheet. '**General Comment: Observed no float breakpoint rope seperating the 4ft depth from 6ft depth. Pool was built in 1984 which means they are grand fathered and not required to have such rope in place. If renovation for the pool take place then it will need to be equipped with break point ropes to meet current code.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Phone number on signage was not the same number that 9-1-1 had on file. CPO wrote the new number on phone signage so it is the exact number that 911 has.

View this inspection on the county portal ›

Apr 18, 2019 22 demerits · 7 violations
Inspector comments: Night swimming is not permitted. Pool hours are from dawn to dusk. Night swimming visit is not required.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris inside pool and pool floor. Observed build-up on top part of pool wall. CDI: pool being cleaned during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris observed in skimmer baskets. CDI: cleaned several times during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed broken metal plate at handrail.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length > 30ft. CDI: rope cut to 30ft during inspection.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2626(a) Post a shower sign visible upon entrance to the pool. No shower sign available.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. Mirrors not shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. No backflow preventor on deck hosebib.

View this inspection on the county portal ›

Apr 11, 2018 8 demerits · 2 violations
Inspector comments: Pool drain covers expire October 2018, an updated PDSC form will need to be submitted by expiration date if pool is to be open through that time. Observed heavy wall damage in the pump room.
#22 · Premises: emergency telephone provided −6
Phone number to the pool was observed faded on the information sign near the telephone. Re-written during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no ventilation provided in the chemical room.

View this inspection on the county portal ›

May 17, 2017 0 demerits · 0 violations
Inspector comments: Pre-permit inspection conducted. Pool Approved.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 15, 2016 8 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Cleaning needed on pool floor and pool wall for pollen build up. Pool has great clarity.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No hot water coming from faucet. Repair.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide a back flow prevention device on hose bib on the pool deckGeneral Comment: Observed damaged sheet rock/ walls in pump/ chemical room. Repair damaged sheet rock in pump/chemical room

View this inspection on the county portal ›

Apr 15, 2015 12 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Clean pool floor and walls.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Replace damaged cap around ladder pole on pool deck.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on back wash line. Back wash line is direct plumbed. Air gap should be on back wash line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Clean toilet fixtures in men and women bathroom. Repair hot water faucet on hand washing sink in men bathroom so water can be turned off at the faucet and not the water line valve under sink. Clean wall and area around door framing in bathrooms.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide a back flow prevention device on hose bib on the pool deck.General Comment: Observed damaged sheet rock/ walls in pump/ chemical room. Repair damaged sheet rock in pump/chemical room. Recommend spray painting " NO DIVING" marking 4 inches in height on corner of pool deck on the six feet end. NO DIVING marking is provided and spaced correctly on pool deck in water five feet and less. Frank Higginbotham present at time of inspection.

View this inspection on the county portal ›

Jun 2, 2014 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chipping and cracking of deck. Keep in good repair.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “ASHBROOK CONDOMINIUMS” or State ID 2060500032). Inspection type (routine vs. follow-up) is not published in the county's data.