‹ Back to search

14demerits

BERKSHIRE PLACE APARTMENTS

7700 CEDAR POINT LANE, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060500041
Latest result14 demerits
Last inspectedJun 9, 2026
Inspections on record13
On record sinceMay 16, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 May 16, 2014: 10May 29, 2015: 12May 12, 2016: 10May 12, 2017: 6May 10, 2018: 0Apr 18, 2019: 10May 13, 2020: 10Aug 24, 2021: 6May 27, 2022: 8May 12, 2023: 18May 3, 2024: 6Apr 14, 2025: 12Jun 9, 2026: 14
May 16, 2014Lower is betterJun 9, 2026

Inspections & violations

Jun 9, 2026 14 demerits · 3 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed equipment and furniture stored within 6 feet of pool deck. CDI, items relocated to provide 6 feet of clearance.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Emergency phone not visible from all areas of pool deck. CDI, signage provided to indicate location.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI, operator corrected to show flow.

View this inspection on the county portal ›

Apr 14, 2025 12 demerits · 2 violations
Inspector comments: Inspection conducted with Josh Foreman on site. REHS called posted number on Kings lll phone after talking to Charlotte 911. Phone responded to call from REHS.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0, corrected during time of inspection to 7.2
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy throw rope 39.0 ‘. CPO cut rope to correct length (36.0 ‘) during inspection - Corrected.

View this inspection on the county portal ›

May 3, 2024 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0, corrected during time of inspection to 7.2

View this inspection on the county portal ›

May 12, 2023 18 demerits · 4 violations
Inspector comments: Night swimming is not approved.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539 - Observed equalizer lines not blocked/plugged in skimmer under basket as indicated disabled by PDSC. Eq line on wall has been plastered. CPO fitted plugs into skimmer equalizer lines during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing or damaged skimmer basket. Observed 1 of 4 skimmer baskets damaged and cracked. CPO replaced on site - Corrected
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. - Observed one ladder step without slip resistant tread.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy throw rope >36’. CPO cut rope to correct length during inspection - Corrected.

View this inspection on the county portal ›

May 27, 2022 8 demerits · 3 violations
Inspector comments: Night swimming is not approved. Resident manager Alexandra James was present during the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in skimmers. CDI- EHS removed debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Ladders shall have slip-resistant tread. - Observed one ladder step without slip resistant tread.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. - EHS and properly manager unable to verify mirrors in restroom are shatterproof.

View this inspection on the county portal ›

Aug 24, 2021 6 demerits · 2 violations
Inspector comments: This pool does not request night swimming.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed loose ladder at the 5ft end of the pool. CDI - Operator tightened. -2-
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no footholds outside fencing or gate. Observed bench and electrical box outside fencing near grill. CDI - Operator moved the bench and is exploring options to remove foothold for electrical box such as installing an incline to prevent foothold. -4-

View this inspection on the county portal ›

May 13, 2020 10 demerits · 2 violations
Inspector comments: Night swimming not permitted.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 47 ft. CDI, thrope cut to proper length.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. CDI, flow meter corrected while on-site.

View this inspection on the county portal ›

Apr 18, 2019 10 demerits · 2 violations
Inspector comments: PDSC information verified in-field during inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no area in log book to record if main drains are secure. CDI- main drain secured column added to log book.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length at greater than 36 feet. CDI- rope was cut to 36 feet.

View this inspection on the county portal ›

May 10, 2018 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 12, 2017 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool floor in need of cleaning.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors in restrooms not shatterproof.

View this inspection on the county portal ›

May 12, 2016 10 demerits · 2 violations
Inspector comments: This is not a pool permit. Pool permit will be available within 2-3 business days on our website at meckpools.charmeck.org. Observed office phone number listed as well as emergency phone number listed near emergency phone number. CDI, operator removed office phone number from emergency pool phone while on-site. Observed some deterioration on concrete deck/pool wall juncture. Observed pool lights not operational during inspection. Operator stated that they run on photo cells and they do not have night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope at 46 feet. CDI, operator cut throw rope length to provide correct length during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed pool gate bouncing back and not self latching upon return when opened. CDI, pool operator adjusted latch during inspection to provide a self-closing gate.

View this inspection on the county portal ›

May 29, 2015 12 demerits · 3 violations
Inspector comments: 25. Observed less than 3 ft clearance in chemicial/pump room and no form of ventilation.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed inlet on bottom of pool floor broken and showing piping. Keep inlet covers in good repair. ITS issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed body hook that was 12ft with collapsible attachments. Have a 12ft pole with noncollapsible attachements. CDI pole that was 12ft attached to body hook.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed hot water in men and womens bathroom at 114F. Keep water no more than 110F.

View this inspection on the county portal ›

May 16, 2014 10 demerits · 2 violations
Inspector comments: 22. General Comment: Recommend to have phone records updated with 911 to include secondary phone number (office line). Currently pool has a Kings III system w/fax line as their designated line. Secondary # would allow for incoming calls to be received. Permit issuedPermit available on website w/in 3 business days.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope for ring buoy should be 36ft. Observed rope 42ft. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not functioning. Corrected during inspection.

View this inspection on the county portal ›