0demerits
BEVERLY WOODS EAST
3815 HUCKLEBERRY RD, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060500044
Latest result0 demerits
Last inspectedMay 5, 2026
Inspections on record14
On record sinceMay 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 9, 2014Lower is betterMay 5, 2026
Inspections & violations
May 5, 2026 0 demerits · 0 violations
Inspector comments: Night swimming approved as long as all the lighting is operational
Lifeguard required
No violations were recorded for this inspection.
Apr 30, 2026 4 demerits · 1 violation
Inspector comments: Call for reinspection when ready.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed 2 gates not self-closing, self-latching.
May 8, 2025 0 demerits · 0 violations
Inspector comments: No violations observed. Night swimming permitted.
No violations were recorded for this inspection.
Apr 26, 2024 8 demerits · 2 violations
Inspector comments: Inspection completed with CPO, Brandon Vaughn
All permit compliance items corrected during inspection
Interlock tested and operating
CPO log records begin today
Drain covers expire 10/1/24
Covers must be replaced and new PDSC form approved prior to inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Two back gates were not self closing. CPO tightened the spring screws and now all gates are self-closing / self latching.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). Observed chairs less that 8ft from the edge of pool. Chairs will be removed when pool opens.
Apr 20, 2023 0 demerits · 0 violations
No violations were recorded for this inspection.
May 12, 2022 8 demerits · 3 violations
Inspector comments: Site visit made for operating permit inspection and construction final. All items listed on previous construction punch list were corrected. Construction final passed.
Permit issued for no night swimming. Stickers issued while onsite. If seeking night swimming, provide photograph documentation that perimeter lights are operable. Pool lights were verified during inspection. Perimeter lights on timer.
Jeff Gaeckle present during the inspection. Your state permit will be emailed to you by end of day.
Pool is lifeguarded at all times.
Verified chlorinator at time of inspection to detect flow.
Verified EQK1500 pump with (2) SUN18HPHxxx drain covers. (15) Aquastar 6HPHAxxx equalizer line covers with blue dot.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on pool floor. Keep clean. Drains clearly visible.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Starting platforms with signage wearing off. When not in use, starting platforms shall meet the following: .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision.
Diving boards not equipped with signage per rule .2517. Diving equipment shall be equipped with proper labeling.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet. No leak could be located. Ensure pump room floor kept dry.
Apr 23, 2021 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf debris present in pool during inspection. PO began cleaning debris during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed 3 ladders loose during inspection. PO able to tighten ladders during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Hole in deck where poles are placed for flags. While pool is operational to public, poles must be in place to eliminate offsets/openings of >1/2". PO provided and installed pole during inspection.
Jun 1, 2020 24 demerits · 8 violations
Inspector comments: Scope of Work - Renovation of Restrooms and Pump room. No change to pool.
Permit issued for no night swimming. Issuance of a permit by this department does not negate closure required by Executive Order No. 141 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
Permit Restriction - Depth of pool requires lifeguards present at all times pool is operational.
Jeff Gaeckle present during inspection. No signature due to Covid restrictions. Red phone signage added near vending machines that states location of emergency phone at front entry. Gate added to front entry to ensure fencing meets code requirements. Temporary meshing installed until permenant repair is made. Must meet code requirements with permanent repair.
Note: No mirrors in restrooms. If installed, provide shatterproof mirrors.
Note: No change to backwash line. Direct plumbed. Hose bibs for restrooms located on deck and outside of building with backflow prevention device.
Pentair EQK1500, 15 hp with (2) SUNHPHxxx drain covers and (15) 6HPHAxxx EQ line covers.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Light by back 4 ft. area protruding from wall. Does not appear to be greater than 1/2". Continue to monitor and repair as needed to eliminate pinch hazard.
Some etching on pool floor. Keep in good repair.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some ladder rungs >6" from wall to rung. Maintain 3" to 6" between ladder rung and wall.
Slip-resistant tread beginning to wear off on diving board. Diving board missing labeling requirements.
.2517(a)2 Provide installation instructions for diving equipment.
.2517(a)4 Diving equipment shall be slip-resistant.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Blue hose bib outside of barrier provides foothold. Pool built pre-2010. Eliminate foothold.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Holes in deck where poles are placed for flags. While pool is operational to public, poles must be in place to elimiante offsets/openings of >1/2".
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Small leak at backwash line. Repair leak. Does not appear to affect circulation of system due to location on backwash line.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet due to leak at backwash line. Keep pump room floor dry.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower sign not posted visible upon entry to pool. Corrected during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Toilets in restrooms in need of cleaning. Keep fixtures clean.
Apr 26, 2019 18 demerits · 4 violations
Inspector comments: Verified PDSC information.
Observed deck furniture not in place at time of inspection. Maintain a 8' clearance around pool.
Permit Restriction:
Pool must be lifeguarded and attended at all hours of operation as front door is not self-closing, self-latching.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor.
.2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers.
Observed skimmer weirs not free floating.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed one gate swinging toward pool. Corrected during inspection.
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present.
#22 · Premises: emergency telephone provided −6
Observed emergency phone signage not posted. Corrected during inspeciton.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Apr 26, 2018 4 demerits · 1 violation
Inspector comments: Visit/Inspection conducted at night; was able to verify night time swimming. Adequate lighting provided. Pool is permitted for night time swimming.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmer baskets. Make sure to keep clean.
May 8, 2017 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed floating debris in pool near steps .
May 12, 2016 4 demerits · 1 violation
Inspector comments: PDSC form shall be completed and approved by MCHD for pool permit to be issued. Unable to verify pump information for main pool in field. Equalizer and main drain cover information verified.
Observed some deterioration / damage to bottom of pool entrance doors on entrance to pool. Repair as needed.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Observed 3 pool lights and some pole lights out on deck. Operator stated pool opens unit 8pm. Pool lights shall be provided for night swimming.
May 8, 2015 12 demerits · 3 violations
Inspector comments: Permit issued Permit will be available on county website in 3 days.
#3 · Water quality: pool water pH −6
Observed 7.0pH at pool. Correction pH increased to 7.2. Pool pH should be at 7.2-7.8.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer baskets with debris. Keep skimmers clean and in good repair.
#31 · Dressing and sanitary facilities: sewage disposed of in a properly operating sewage system −2
Observed no air gap present for back wash line, but sight glass in place. Backwash shall be discharged through an indirect drain.
May 9, 2014 4 demerits · 2 violations
Inspector comments: 22. Observed emergency phone properly functioning and correct phone number and address listed with 911 operator. Permit issued.Permit available on website with in 3 business days.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label return line in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap present for backwash line; sightglass present in place.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BEVERLY WOODS EAST” or State ID 2060500044). Inspection type (routine vs. follow-up) is not published in the county's data.