6demerits

CARMEL VILLAGE I

10995 HARROWFIELD ROAD, Charlotte, NC 28226
Seasonal Swimming Pool · NC permit/State ID 2060500072
Latest result6 demerits
Last inspectedJul 2, 2026
Inspections on record13
On record sinceJul 17, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Jul 17, 2014: 28Apr 29, 2015: 8Jun 7, 2016: 12May 30, 2017: 18Apr 17, 2018: 6May 31, 2019: 10May 27, 2020: 4May 25, 2021: 14May 26, 2022: 24May 26, 2023: 0May 22, 2024: 6Jul 1, 2025: 16Jul 2, 2026: 6
Jul 17, 2014Lower is betterJul 2, 2026

Inspections & violations

Jul 2, 2026 6 demerits · 1 violation
Inspector comments: EHS observed flow meter reading above 115 GPM (this is the top readable value on flow meter). Per permit restrictions, flow is to be maintained above 103GPM never to exceed 119GPM. CPO adjusted flow on VSP to 3400 (set to 3450), and EHS observed flow reduce to 115 and lower. CPO stated GPM will be set to 3400GPM and monitored.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. EHS observed rope at a greater than 1.5 times the pool. Pool is required to have a rope at 43ft. CDI -CPO cut rope to length.

View this inspection on the county portal ›

Jul 1, 2025 16 demerits · 4 violations
Inspector comments: The following items were verified during the inspection: 1. Permit Restriction: Flow meter shall remain operable. Flow shall be kept at 103 gpm due to return line flow restriction. 6-hour turnover not met due to restriction. 2. New Pump Hayward TristarVS950 HCP32950VSP, 2.7 THP 3. Flowvis flow meter reading the above permit restriction. 4. (2) Aquastar A10RCFRxxx 2017 drain covers. 5. Main drain, skimmer and return line all 2” line coming through pump room floor. 6. (3) skimmers with EQ lines plugged in skimmer and plugged/plastered on wall. 7. 6 returns, either on the floor or the wall. 8. (1) Pentair TR140C filter.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool plaster in disrepair with significant damage noted in shallow end of pool. Pool must be replastered prior to issuance of operating permit in 2026.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed rope for ring buoy to be longer than 1.5 times the width of the pool (42ft). - CDI - CPO corrected rope length to 42ft.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Per permit restrictions, flow meter must read 103GPM due to return line flow restriction. Observed flow meter reading 95GPM upon EHS arrival. - CDI - CPO cleaned filter and backwashed pool. Observed flow meter reading 103GPM after corrections.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. - No hose bib provided in or near restrooms. Provide hose bib.

View this inspection on the county portal ›

May 22, 2024 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. CDI - pH corrected to 7.4 during inspection.

View this inspection on the county portal ›

May 26, 2023 0 demerits · 0 violations
Inspector comments: no demerits taken

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 26, 2022 24 demerits · 6 violations
Inspector comments: Pool is not permitted for night swimming. Main drain covers expire 9/15/22. A verification visit will be conducted before this date to ensure drain covers have been changed. Failure to do so will result in pool permit being suspended.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Leaf debris and other organic material present on pool service.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum port with missing cap. CDI- Cover provided that needs a tool to remove during the inspection by the CPO.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope well below 42 feet. CDI- Ring buoy rope replaced during the inspection by CPO.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Pool phone was replaced due to bad call quality during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed pump room with standing water on flooring around equipment. Note: pump room walls with significant areas of disrepair present and some holes opening through to outside. Ensure pump room remains weatherproof and inaccessible.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Unable to determine if mirror shatterproof. .2526(m) Keep restrooms and fixtures clean and in good repair. Observed womens restroom toilet in disrepair and men’s restroom toilet missing cover. Repair. Fixtures in both restrooms in need of cleaning.

View this inspection on the county portal ›

May 25, 2021 14 demerits · 4 violations
Inspector comments: Pool not approved for night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Leaf debris and other organic material present in bottom of the pool. Cleaning needed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 40 feet instead of required 42 feet. PIC corrected on site to 42 feet as required.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed pump room with standing water on flooring around equipment. Note: pump room walls with significant areas of disrepair present and some holes opening through to outside. Ensure pump room remains weatherproof and inaccessible.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Unable to determine if mirror shatterproof. .2526(m) Keep restrooms and fixtures clean and in good repair. Observed womens restroom toilet in disrepair and men’s restroom toilet missing cover. Repair. Fixtures in both restrooms in need of cleaning.

View this inspection on the county portal ›

May 27, 2020 4 demerits · 1 violation
Inspector comments: No signature required due to COVID-19 guidelines.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed cleaning needing to be done inside skimmers.

View this inspection on the county portal ›

May 31, 2019 10 demerits · 2 violations
Inspector comments: Some wall damage in pump and chemical room. Repairs to walls needed. Night swimming not permitted at this pool. Ensure permit remains visible.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Initial check of chlorine testing at 0ppm. CDI- CPO TJ Havens was able to correct during inspection. Re-test of chlorine; sample of 3.0ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Leaf debris across bottom of the pool. Cleaning needed.

View this inspection on the county portal ›

Apr 17, 2018 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose stairs. Make sure to tighten.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed opening under fence greater than 4 inches (front side entrance). Make sure to repair.

View this inspection on the county portal ›

May 30, 2017 18 demerits · 4 violations
Inspector comments: Damage to pool sign. Make sure to replace next season. Emergency phone hard to hear; still operating and connects to 911. Make sure to post pool permit.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Unable to see pool bottom and main drains. Immediate Suspension.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No records for when the pool opened.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Loose hand rail; tighten.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy greater than 41 feet. CDI Cut down to 41 feet.

View this inspection on the county portal ›

Jun 7, 2016 12 demerits · 4 violations
Inspector comments: #5: General Comment: Ensure that visual inspection is checked on log daily. (Main drain) #18: General Comment: Warning signs are beginning to fade. Replace prior to 2017 season.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form does not reflect existing drain information. Corrected: Updated PDSC
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ensure that ladders are tight and secure. Check frequently. Corrected
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Noted broken water fixture in female restroom. Mirrors in restroom are not constructed of shatterproof materials.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Provide vacuum breaker/backflow prevent on all hose bibs.

View this inspection on the county portal ›

Apr 29, 2015 8 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in the skimmers.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed the pump room floor wet.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed A leak at the handsink in the women's room. CDI- leak repaired.Report emailed to brandon.vaughn@charlotte-pmg.comPermit will be available online when the PDSC forms have been received approved.

View this inspection on the county portal ›

Jul 17, 2014 28 demerits · 9 violations
Inspector comments: Intent to Suspend issued for #8
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some chipping paint on pool floor. Keep in good repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmers full. Keep clean. One equalizer plugged. Remove plug. Intent to Suspend issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope >50 ft. Corrected to 42 ft.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump room floor wet. Keep dry.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line direct plumbed. Provide air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
No shower sign. Post visible.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water >115 F in restrooms. Maintain at 110 F or below.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide backflow prevention device on all hose bibs on deck and in pump rom.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No hose bib or floor drain in restrooms. Provide.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CARMEL VILLAGE I” or State ID 2060500072). Inspection type (routine vs. follow-up) is not published in the county's data.