‹ Back to search

0demerits

CHARLOTTE HOUSE

1323 QUEENS ROAD 207, Charlotte, NC 28207
Seasonal Swimming Pool · NC permit/State ID 2060500103
Latest result0 demerits
Last inspectedApr 15, 2026
Inspections on record13
On record sinceApr 17, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0714 Apr 17, 2014: 14Apr 1, 2015: 4Apr 7, 2016: 0Apr 4, 2017: 4Apr 6, 2018: 10Apr 4, 2019: 6Apr 14, 2020: 4Apr 13, 2021: 12Apr 13, 2022: 6Apr 6, 2023: 4Apr 2, 2024: 4Apr 10, 2025: 4Apr 15, 2026: 0
Apr 17, 2014Lower is betterApr 15, 2026

Inspections & violations

Apr 15, 2026 0 demerits · 0 violations
Inspector comments: Pool open for 2026 season. No night swimming. Flow meter was stuck. Pool operator corrected it onsite. No permit restrictions.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 10, 2025 4 demerits · 1 violation
Inspector comments: No permit restrictions. No night swimming. Inspection conducted with CPO Pierce Sawyer NOTE: Pool built without equalizers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed more than 4-5” under chain link fence. -CDI- Fence posts were bent possibly due to lawn care. Pool operator straightened them to meet compliance of no greater than 4”.

View this inspection on the county portal ›

Apr 2, 2024 4 demerits · 1 violation
Inspector comments: Inspection completed with Pierce Sawyer. No night swimming. Open from dusk to dawn.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed more than 4-5” under fence. -CDI- Fence posts were bent possibly due to lawn care. Pool operator straightened them to 2-3” under fence.

View this inspection on the county portal ›

Apr 6, 2023 4 demerits · 1 violation
Inspector comments: Inspection completed with Pierce Sawyer No night swimming. Open from dusk til dawn.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed cork deck material that is starting to wear away and in need of repair before trip hazards arise. Repeat.

View this inspection on the county portal ›

Apr 13, 2022 6 demerits · 2 violations
Inspector comments: No night swimming permitted Pool hours are from dusk to dawn per operator. 40 GPM
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed cracks of deck that need repairing.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed no forced air ventilation in pump room

View this inspection on the county portal ›

Apr 13, 2021 12 demerits · 3 violations
Inspector comments: Night swimming not permitted. Pool hours are from dawn to dusk per operator. General Comment: Observed some minor damage to pool deck.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Observed a no diving marker no longer clearly visible / legible. CDI, new stencil and marker provided.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed throw rope and buoy in poor repair. CDI, new ring buoy and throw rope provided.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed area of floor near pump in equipment room wet with some water.

View this inspection on the county portal ›

Apr 14, 2020 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs less than 6 ft. on deck. CDI - CPO moved chairs on deck at least 6 ft. away.

View this inspection on the county portal ›

Apr 4, 2019 6 demerits · 3 violations
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Pool floats spaced more than 5' apart. CDI
#27 · Equipment room: filter backwash discharged through an air gap −2
no air gap for back wash
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
water in bathroom greater than 110 degrees. Mirror made of glass. Mirrors must be shatter proof.

View this inspection on the county portal ›

Apr 6, 2018 10 demerits · 4 violations
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Observed safety rope less than 3/4". CDI rope replaced with correct diameter rope.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence in disrepair in several areas allowing greater than 4" gap at bottom. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on backwash line.

View this inspection on the county portal ›

Apr 4, 2017 4 demerits · 2 violations
Inspector comments: Pre-permit inspection. Pool approved.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no cross ventilation in chemical storage area.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap where backwash is discharged between pipe and drain.

View this inspection on the county portal ›

Apr 7, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 1, 2015 4 demerits · 2 violations
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Observed safety rope anchors not recessed.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof, and water >110F in bathrooms.General Comment #15: Shepards crook has been damaged, and has sharp edges, please replace.

View this inspection on the county portal ›

Apr 17, 2014 14 demerits · 4 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Faded "NO DIVING" stencil at steps. Must make visible. COS.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Damaged ring bouy. Replace. COS
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No cross ventilation in chemical room. Provide crossed or forced ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap on backwash line. Provide an air gap above the floor grade.General Comments: Pierce Sawyer present.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CHARLOTTE HOUSE” or State ID 2060500103). Inspection type (routine vs. follow-up) is not published in the county's data.