‹ Back to search

4demerits

CHESHUNT SWIM TENNIS CLUB

4200 BROWNES FERRY RD, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500113
Latest result4 demerits
Last inspectedMay 12, 2026
Inspections on record15
On record sinceMay 29, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01020 May 29, 2014: 20Jun 23, 2015: 10May 19, 2016: 18May 12, 2017: 14May 4, 2018: 10May 1, 2019: 12May 13, 2020: 4Apr 14, 2021: 10Apr 6, 2022: 6Jun 2, 2023: 4Apr 19, 2024: 10May 5, 2025: 8Apr 13, 2026: 18May 1, 2026: 4May 12, 2026: 4
May 29, 2014Lower is betterMay 12, 2026

Inspections & violations

May 12, 2026 4 demerits · 1 violation
Inspector comments: Flow meter must remain operable. Flow shall not exceed 380 gpm due to drain Cover Flow restriction. Suction Hazard. Note: 5 hp impeller in 7.5 hp pump - placard does not indicate correct pump (EQKT-750). Impeller reduces pump flow to EQ500. NOT APPROVED FOR NIGHT SWIMMING. Construction: 1/1/1991 Rope: 50’
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Hole designated for pole left open and uncovered on sides of pool. CPO to cap holes or have poles inserted.

View this inspection on the county portal ›

May 1, 2026 4 demerits · 1 violation
Inspector comments: Flow meter must remain operable. Flow shall not exceed 380 gpm due to drain Cover Flow restriction. 5 hp impeller in 7.5 hp pump - placard does not indicate correct pump (EQKT - 750). Impeller reduces pump flow to EQ500. Construction date: 1/1/1991 Rope Length: 50’ No Lifeguard required. NOT PERMITTED FOR NIGHT SWIMMING. Inspection conducted with EHS intern Ericka J observing.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Pool fence with 2” gap due to not being secured to low horizontal wire. CPO secured during inspection.

View this inspection on the county portal ›

Apr 13, 2026 18 demerits · 4 violations
Inspector comments: Flow meter must remain operable. Flow shall not exceed 380 gpm due to drain Cover Flow restriction. 5 hp impeller in 7.5 hp pump - placard does not indicate correct pump (EQKT - 750). Impeller reduces pump flow to EQ500. Construction date: 1/1/1991 Rope Length: 50’ No Lifeguard required.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Water level shall be maintained to assure skimmers are operable. Water level too low to assess skimmer operability. .2518(k) Replace missing weirs. One weir missing, one weir obstructed. CPO repaired during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Two open holes in middle sections of pool on opposing sides needing to be covered or filled.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone inoperable during inspection. Return visit required. Permit denied.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Acquire spare basket for pump.

View this inspection on the county portal ›

May 5, 2025 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.

View this inspection on the county portal ›

Apr 19, 2024 10 demerits · 3 violations
Inspector comments: No night swimming. Inspection conducted with CPO Danielle Parker No permit restrictions.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers. CDI: cleaned during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). Observed chairs providing < 8ft clearance on one side of deck. CDI: chairs were moved to the other side.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors not shatterproof.

View this inspection on the county portal ›

Jun 2, 2023 4 demerits · 1 violation
Inspector comments: Door to restrooms to stay unlocked during all hours of operation for access to pool emergency phone.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed anchor for cover sticking up over 1/2 inch. Observed chairs within 8 feet of pool deck. .2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Corrected during inspection.

View this inspection on the county portal ›

Apr 6, 2022 6 demerits · 3 violations
Inspector comments: 22. Add directional sign to front of building location emergency phone 29. Soap in dispenser but dispenser not working
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder and handrail tightened down during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights and fan not in working order
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Valves and pipes marked during inspection

View this inspection on the county portal ›

Apr 14, 2021 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
Observed pH at 7.0 increased to 7.2 during the inspection. **.2535(1) Maintain pH at 7.2 to 7.8.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris in pool needs to be cleaned. **.2537(14) Keep pool surface and pool floor free of debris.

View this inspection on the county portal ›

May 13, 2020 4 demerits · 1 violation
Inspector comments: no night swimming. permit issued
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed only 4ft of deck clearance around one side of pool. CDI- Pool operator moved chairs.

View this inspection on the county portal ›

May 1, 2019 12 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter not operating. CDI- Meter began operating after adjustment.

View this inspection on the county portal ›

May 4, 2018 10 demerits · 3 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq ft). Observed pool with only 5 ft clearance with lawn chairs. CDI items moved. .2537(2) Decks shall be kept in good repair. Observed cracks around caulking and cracks on other areas on pool deck in need of filling.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. No spare basket for pump. CDI basket provided.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed lines in pump room in need of labeling to show flow of water.

View this inspection on the county portal ›

May 12, 2017 14 demerits · 5 violations
Inspector comments: 15. Recommend located body hook in a more accessible location 22. Recommend new phone location sign - current one faded & needs directional arrow Pool passed pre-inspection pending approval of updated PDSC forms
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Keep baskets free of debris
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders & handrails tightened during inspection
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Several cracks in deck need to be filled in with caulk or cement
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
New bulbs needed in lights
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line

View this inspection on the county portal ›

May 19, 2016 18 demerits · 6 violations
Inspector comments: PDSC Form verified.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 1 weir missing. CDI- CPO installed new weir during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrails loose on ladders and steps. Repair.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length to be 54 Ft. Length needed - 50 F. CDI- CPO cut rope to correct length.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed fan not operational in pump room. Repair.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap present at backwash. Provide.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirors in women's and men's restroom to not be shatter resistant. Replace.

View this inspection on the county portal ›

Jun 23, 2015 10 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed on cracked skimmer cover next to the slide.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no cross or continuous ventilation in the pump/chemical room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash Line has no air gap. End of the pipe extends into the pit.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed outside shower not working. Facility has showers in the restrooms.

View this inspection on the county portal ›

May 29, 2014 20 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two weirs were stuck, not operating. Weirs corrected during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain 6 ft clearance on main pool deck. Observed 5 ft deck clearance from deck chairs. Corrected during inspection.
#22 · Premises: emergency telephone provided −6
Pool phone number and address not posted at pool phone. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meters stuck, not operating. Corrected during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
Need air gap from backwash pipe from height of drain pit.

View this inspection on the county portal ›