‹ Back to search

6demerits

CHURCHILL DOWNS APARTMENTS

950 CHURCHILL DOWNS COURT, Charlotte, NC 28211
Seasonal Swimming Pool · NC permit/State ID 2060500117
Latest result6 demerits
Last inspectedApr 16, 2026
Inspections on record13
On record sinceApr 28, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Apr 28, 2014: 0Apr 22, 2015: 18Apr 21, 2016: 0May 11, 2017: 8Apr 19, 2018: 6May 10, 2019: 10Apr 15, 2021: 10May 25, 2022: 8May 9, 2023: 6Apr 24, 2024: 10Apr 8, 2025: 22Apr 9, 2025: 6Apr 16, 2026: 6
Apr 28, 2014Lower is betterApr 16, 2026

Inspections & violations

Apr 16, 2026 6 demerits · 2 violations
Inspector comments: PERMIT RESTRICTION: 5% ACCURATE FLOW METER MUST REMAIN OPERABLE. PUMP SHALL BE SET AT 66 GPM TO 80 GPM TO MEET TURNOVER AND FLOW RESTRICTION FOR THE # OF RETURNS. FLOW GREATER THAN 119 GPM IS SUCTION HAZARD. NO NIGHT SWIMMING. Note: During today's routine inspection, EHS observed flow meter was at 60 GPM. After CPO had done a backwash, flow meter was within the above mentioned range.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface. CPO in the process of cleaning.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Observed pump room has ceiling height less than 7ft.

View this inspection on the county portal ›

Apr 9, 2025 6 demerits · 2 violations
Inspector comments: Permit restrictions: Flow meter must remain operable. Pump shall be set at 66 GPM to 80 GPM to meet turnover and flow restriction for # of returns. Inspection completed with CPO Jorge. No night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed minor debris on pool floor. CDI: Cleaning on site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Observed pump room with a ceiling height of less than 7ft.

View this inspection on the county portal ›

Apr 8, 2025 22 demerits · 5 violations
Inspector comments: Permit restrictions: Flow meter must remain operable. Pump shall be set at 66 GPM to 80 GPM to meet turnover and flow restriction for # of returns. Inspection completed with CPO Jorge. Permit denied due to flow rate on meter only reading 55 GPM. Pump shall be set at 66 GPM to 80 GPM to meet turnover and flow restriction for # of returns. Pool placed on Q status. Please contact our main office at 980-314-1620 to request a reinspection and pay $100.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed pool flow rate at 55gpm. Permit restriction requires pump to be set to 66gpm to 80 GPM to meet turnover and flow restriction for # of returns . Permit denied and pool placed on Q status.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on bottom of pool floor. CDI: cleaning during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope length > 36ft. CDI: cut to 36ft during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed less than 6ft walking space around deck due to lawn chairs. CDI: lawn chairs moved back to provide 6ft clearance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Observed ceiling height less than 7ft.

View this inspection on the county portal ›

Apr 24, 2024 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed minor debris on pool floor. Clean as needed.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Observed pipe where chlorinator pipe attaches leaking during inspection. CPO was able to fix leak during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Observed pump room with a ceiling height of less than 7ft.

View this inspection on the county portal ›

May 9, 2023 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed 60 ft rope. Rope cut to required length of 36”.

View this inspection on the county portal ›

May 25, 2022 8 demerits · 3 violations
#19 · Premises: signs prohibit glass containers or pets in pool area −4
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area. Observed posted sign does not meet sign requirements. CDI located state pool rule sign and installed on pool deck.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft. Observed chemical storage in pump enclosure on pool deck and does not meet 7 ft ceiling height requirement.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors in restrooms not shatterproof.

View this inspection on the county portal ›

Apr 15, 2021 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaf debris on pool floor.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate to be sticking on concrete( marks on concrete of gate contact over time) Operator repaired onsite; now closing freely.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Observed mimumum ceiling height in pump room to be only 48 inches.

View this inspection on the county portal ›

May 10, 2019 10 demerits · 3 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth makers are faded and need to be repainted stickers was placed with no diving makers and placed around pool
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter was stuck
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Clean up pump room and pool chemicals testers that are on the ground.

View this inspection on the county portal ›

Apr 19, 2018 6 demerits · 2 violations
Inspector comments: Verified updated PDSC form during inspection.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed one instance of NO DIVING lettering still clearly visible but faded from original opacity. Monitor and re-paint signage when needed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed some chemicals such as pool salt, and waterproof containers of muriatic acid kept out of the enclosed chemical/pump shed.

View this inspection on the county portal ›

May 11, 2017 8 demerits · 2 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed depth markets 40' fromeach other around the perimeter- new depth markets put down so that they were <25' apart.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed the gate not self closing when it is barely opened- correctedduring inspection so that it is self closing and self latching.

View this inspection on the county portal ›

Apr 21, 2016 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 22, 2015 18 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed chlorine sticks in skimmer baskets. CDI-sticks removed. cannot put chlonine in skimmers, chlorine pump must be used.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate not self-closing self-latching. CDI-gate self closure adjusted.
#22 · Premises: emergency telephone provided −6
Observed the emergcy phone had wrong number posted. CDI-changed posted number
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room has less than 7 feet of vertical height and less than 3 feet of walk space to access equipment.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof.

View this inspection on the county portal ›

Apr 28, 2014 0 demerits · 0 violations
Inspector comments: Pool operator must print and publicly post the pool permit. Pool cannot open without properly posted permit.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “CHURCHILL DOWNS APARTMENTS” or State ID 2060500117). Inspection type (routine vs. follow-up) is not published in the county's data.