28demerits
OAK PARK AT NATIONS FORD APTS
103 DINADAN DRIVE, Charlotte, NC 28217
Seasonal Swimming Pool · NC permit/State ID 2060500119
Latest result28 demerits
Last inspectedJul 28, 2020
Inspections on record5
On record sinceJun 11, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 11, 2014Lower is betterJul 28, 2020
Inspections & violations
Jul 28, 2020 28 demerits · 6 violations
Inspector comments: Onsite visit with Maria Attomare for pool inspection.
Completed survey for renovations.
.2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments.
Provide the following documentation prior to the next inspection:
Could not verify if tile in bathroom is slip resistant
.2526 Bathroom flooring shall be slip resistant.
Could not verify if mirror are shatterproof or safety backing tape has been applied.
.2526 Provide shatterproof mirrors.
Call Chris Sells when all items have been completed.
No signature due to COVID19 social distancing.
#2 · Water quality: disinfectant residual provided by −6
Observed Cl at 0.4ppm.
.2535(4) Maintain chlorine at least 1.0 ppm.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC form incorrect, skimmer equalizers plugged. Unplug equalizer lines or update PDSC.
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance.
Observed skimmer equalizers sticking out from wall at shallow end equalizer and equalizer on side of pool opposite of gate.
.2537(7) Drain covers shall be in good condition and securely attached.
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing end caps. Replace.
.2521 Install ladders per manufacturer instructions.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence and gate replaced, installed 2019.
Gate not self closing, gate is getting hung on ground.
.2537(b) All gates and doors shall be self-closing, self-latching.
Observed gate with 5 1/2" from ground.
Observed fence over 2" from ground throughout.
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).
#22 · Premises: emergency telephone provided −6
Observed no emergency phone signage. Corrected during inspection.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck.
.2518(g) Keep flow meter operational.
Jul 13, 2017 34 demerits · 8 violations
Inspector comments: Immediate suspension issued for violation #6 and #15. Pool closed and gate locked. Contact Arlene Lawrence at 704-617-3068 when all items are corrected.
NOTE: Remove plugs from inside skimmer leading into the pool or provide operable skimmers for the 2017 pool season. Observed all skimmers plugged on inside leading out into the pool.
If you have any other questions you can contact Tim Dutcher, Supervisor over pools at 704-507-6808.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Maintain daily check of main drains and weekly checks of total alkalinity and cyanuric acid. Observed no recordings of daily main drain checks or weekly total alkalinity or cyanuric acid checks.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed Stingl Switch SR-500 system for single main drain not working. Power has been cut off to this system and a manual electric panel has been installed. Stingl Switch system needs to be repaired to work properly for an automatic shut off. (Immediate suspension issued).
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 out of 4 weirs missing from skimmers. Replace.
Observed numerous amount of debris in skimmer baskets. Cleaned during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 2 rubber end caps missing on ladder. Replace
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope length on ring buoy at 39ft. Provide rope length at 50ft as required. (Immediate suspension issued).
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed some areas on chain link fence greater than 4 inches.
Observed some areas of chain link fence where distance underneath was greater than 2 inches.
#18 · Premises: lifeguards present or warning signs posted −4
Observed "No-Lifeguard on Duty" sign that was posted had lettering less than 4 inches in height.
Observed other warning signs with exact wording missing. CDI: all correct signage found in pump room and will be posted around pool.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not working. Repair.
Jun 3, 2016 8 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder without end cap, ladder had slight give when manipulated.
#22 · Premises: emergency telephone provided −6
Phone observed to be non-functioning at time of inspection. Permit suspended immediately until service restored.
Jun 24, 2015 22 demerits · 5 violations
Inspector comments: Intent to suspend issued for deck and missing tiles. An inspection will occur in 30 days to to ensure compliance with intent items.For questions please call Chris Sells at 704 336 5549.
#3 · Water quality: pool water pH −6
Observed pH at 7.0 corrected to 7.2 during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed tiles missing on pool wall. **Intent item**
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy rope length at 50 feet. Corrected to 38 during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck with gaps greater than 1 inch from settling. **Intent item**
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed mirror not shatterproof in restrooms. Provide shatterproof mirror in restroom.
Jun 11, 2014 22 demerits · 6 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Maintain weekly CA and TA readings. Observed none.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed StingL switch not operating on single main drain pool. Must have operable SVRS- Immediate suspension issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed end caps missing on ladder.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed some areas under the fence <4 inches. Maintain less than 4in
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no ventillation in pump room.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “OAK PARK AT NATIONS FORD APTS” or State ID 2060500119). Inspection type (routine vs. follow-up) is not published in the county's data.