10demerits
COTSWOLD ON WALKER
4339 HATHAWAY ST, Charlotte, NC 28211
Seasonal Swimming Pool · NC permit/State ID 2060500125
Latest result10 demerits
Last inspectedApr 22, 2026
Inspections on record15
On record sinceApr 21, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 21, 2014Lower is betterApr 22, 2026
Inspections & violations
Apr 22, 2026 10 demerits · 2 violations
Inspector comments: REPLACE EXPIRING DRAIN COVERS BEFORE DRAIN COVERS EXPIRATION DATE OF OCT. 23, 2028. NAME PLATE SAYS WGEDS-8 WHICH IS A DUAL SPEED PUMP - ONLY HAVE A SINGLE SPEED MOTOR INSTALLED. SAME PUMP CURVE.
NO NIGHT SWIMMING.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
Observed pool water pH measuring 7.0.
CPO corrected during inspection and added sodium bicarbonate to raise pool's pH and EHS observed pH was now measuring 7.4.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed debris on pool floor.
CPO stated they had just pressure washed the pool deck and cleaning crew was going to come out to finish the pool floor.
Apr 24, 2025 16 demerits · 4 violations
Inspector comments: No permit restrictions.
Note: Name plate on pump says WFEDS-8 which is a dual speed pump. Only has a single speed motor installed with same pump curve.
No night swimming
Inspection conducted with CPO Pierce Sawyer.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed no chlorine in pool - reading 0ppm. CDI: corrected 4ppm during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed leaves inside the pool floating and debris on the pool floor. CDI: cleaned during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets with leaves. CDI: cleaned during inspection.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool. Observed no shower sign. CDI: shower sign provided.
May 22, 2024 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.0. -CDI- PIC corrected pH to 7.8.
May 20, 2024 10 demerits · 2 violations
Inspector comments: .2530(f) Emergency phone shall remain operable.
CPO could not get dial tone or outcall on emergency phone.
No permit issued.
Phone is not operable.
CPO will call office 980-314-1620 to pay and reschedule pool inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed some debris inside the pool floating and on the pool floor.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
CPO could not get dial tone or outcall on emergency phone.
Apr 20, 2023 2 demerits · 1 violation
Inspector comments: Pool operates from dusk til dawn.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Observed light bulbs that were not operational in chemical/pump room
Apr 7, 2022 8 demerits · 2 violations
Inspector comments: No night swimming permitted.
Pool hours will be from dawn til dusk per operator
90 GPM
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instructions. Observed debris in skimmer baskets. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed opening in fence greater than 4”x4. Pool operator corrected during permit.
Apr 6, 2021 8 demerits · 2 violations
Inspector comments: Night swimming not permitted.
Some minor debris in pool.
Pool operating hours dawn until dusk.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 7 inches under grade of ground to bottom horizontal on fence at fence near equipment room.Pool is Pre-2010.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Provide required 6ft. deck clearance. Observed pool furniture stacked within required clearance. CDI, pool furniture relocated to provide required deck clearance to prevent trip hazard.
Apr 16, 2020 6 demerits · 1 violation
Inspector comments: Night Swimming has not been permitted.
The "No Diving" sign is still legible but is beginning to fade. Will need to be re-drawn by next pool season.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Observed rope length 2 feet smaller than required. This was corrected and a new rope with the correct 29 feet length was added.
Apr 18, 2019 6 demerits · 2 violations
Inspector comments: Ensure bushes remain cut back so that signs are visible
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Crack in deck currently not more than .5" offset. Has been previously filled. Monitor cracks to ensure offsets are not greater than .5"
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for back wash
Sep 5, 2018 18 demerits · 4 violations
Inspector comments: Drains verified but not pool pump.
Stair railings has screws protruding out
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
debris in the skimmers/covers not in good repair could cause injury.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Moved body hook that was behind bushes and moved to conspicuous and convenient location @ all times.CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Tree beside fence makes pool accessible/branch
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
ITS-Trip hazards and off sets greater than 1/2 inch need correction within 30days
chairs need to be moved to 6ft space around pool
Apr 27, 2018 0 demerits · 0 violations
Inspector comments: New ring buoy was switched to a new one in the field.
No violations were recorded for this inspection.
Apr 24, 2017 8 demerits · 2 violations
Inspector comments: Handrail on walk way is in bad repair- highly recommend to repair for safety.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in baskets-c lean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed <48" from the ground to the top of the fence/walk way. Ground dug out today to provide for enough height to avoid anyone jumping over the fence. Watch erosion on the top and bottom side of the fence/walkway/lattice.
Apr 28, 2016 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 17, 2015 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy dry rotted. CDI-replaced
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck doesn't have at least 6 feet of unobstructed walk space. Deck has a trip hazard, if it gets greater than 1/2 inch offset it will need to be repaired.
Apr 21, 2014 0 demerits · 0 violations
Inspector comments: Facility must print and post permit. Do not open without new permit properly posted.Inspection from 1:55pm to 2:45pm
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “COTSWOLD ON WALKER” or State ID 2060500125). Inspection type (routine vs. follow-up) is not published in the county's data.