4demerits
DELTA CROSSING
6000 DELTA CROSSING LANE, Charlotte, NC 28212
Seasonal Swimming Pool · NC permit/State ID 2060500168
Latest result4 demerits
Last inspectedMay 20, 2026
Inspections on record16
On record sinceJul 16, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 16, 2013Lower is betterMay 20, 2026
Inspections & violations
May 20, 2026 4 demerits · 1 violation
Inspector comments: NIGHT SWIMMING NOT PERMITTED INTHIS FACILITY.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed under fence distance to be more than 4”. Needs to be covered.
May 5, 2026 20 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed multiple debris in the skimmer. Needs cleaning.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy in disrepair. Needs to be replaced.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed under fence distance to be more than 4”. Needs to be covered.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed phone able to call but unable to receive calls during inspection. Needs to be fixed.
May 8, 2025 4 demerits · 1 violation
Inspector comments: NIGHT SWIMMING NOT PERMITTED
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not operating. CPO was able to get flow meter to function during time of inspection.
May 24, 2024 0 demerits · 0 violations
Inspector comments: Mason Storm present for inspection.
No violations noted on this re-inspection.
No night swimming.
No violations were recorded for this inspection.
May 14, 2024 12 demerits · 2 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. PDSC form has not been updated and approved. Current PDSC form indicates 3 Waterway 640-803 equalizer covers. Covers have been removed and lines plastered over. Ensure main drain information is correct. Update PDSC form and submit for approval.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope not attached to ring buoy. Provide rope of 50’.
May 25, 2023 8 demerits · 3 violations
Inspector comments: EHS observed 2 doors leading from the front office to the pool deck which are used for the gym. The 2 doors have locks which are 36 inches from the floor and can be easily unlocked by children. EHS recommended locking the door from the pool deck to the restrooms which is in between the gym. This latch is 58 inches from the floor. EHS recommended locking this door until an audible alarm can be installed on door leading from pool deck to restrooms.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b)(3)(B) The leading edge of handrails facilitating stairs and pool entry/exit shall be no more than 18 inches horizontally from the vertical plane of the bottom riser. Distance from leading edge of handrail to vertical plane of bottom riser measured 27 inches. Replace handrail during next planned renovation with a longer handrail to ensure distance from leading edge of handrail is 18 inches or less from vertical plane of bottom riser.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Audible alarm for door leading from office to pool deck was turned off. Pool operator turned audible alarm on. Keep audible alarm turned on.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Provide restrooms at all pools except for hotels, motels, condominiums and apartments where pool use is restricted to guests and residents. Door leading to restrooms is kept locked until an audible alarm can be installed to prevent children from entering pool deck unattended.
May 4, 2022 4 demerits · 1 violation
Inspector comments: No night swimming permit
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Did not have a column on the check list for drains. Corrected on site. New form printed with drain column.
Jun 2, 2021 0 demerits · 0 violations
Inspector comments: PDSC forms for main drain covers updated. Facility in compliance.
No violations were recorded for this inspection.
Jul 24, 2020 4 demerits · 1 violation
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
two inlet covers missing, replaced during inspection.
May 21, 2019 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed buildup of debris inside weirs baskets and skimmers. CDI - Operator cleaned these out during inspection. -4-
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 5" gap under fence and gate at main entrance to pool. CDI - PIC backfilled with straw to restored required space. -4-
Jun 21, 2018 2 demerits · 1 violation
Inspector comments: Night swimming not permitted at this time and lights in pool are not working. Facility must schedule with inspector to evaluate lighting at night before night swimming can be approved. Local permit number 18-600387.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
11- .2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter. One ladder has been removed creating more than 75F between the ladder and steps. Replace missing ladder.
Jul 12, 2017 30 demerits · 6 violations
#3 · Water quality: pool water pH −6
Observed pool ph at 7.1 at beginning of inspection. Was raised to 7.2 by end of inspection by operator before the end of the inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed three days of chemical log not recorded with a corrective action on low pH. Ensure that the corrective actions to chemicals and pool hazards are recorded.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool rim tiles chipped in some places. Ensure that the tile is repaired. Damage is concentrated in a small area, no ITS issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one weir not secured in a skimmer basket
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Buoy throw rope was heavily tangled at the beginning of inspection, unravelled by EHS. Ensure that the rope is kept untangled and available.
#22 · Premises: emergency telephone provided −6
Signage was not provided at the phone area for the address and return phone number. Provided during inspection by office staff.
Jun 7, 2016 30 demerits · 6 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed Paramount SDX Retro main drain covers but Hayward covers on submitted PDSC form. Re-submit form. Immediate suspension of permit pending approval of PDSC.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 2 weirs missing out of 3. Floating debris in skimmers.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Bluoy throw rope 55 ft. Trimmed to required 50 ft during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed door from leasing office to pool enclosure not self-latching. One gate swings inward towards pool. Observed more than 2" clearance under section of fence on retaining wall. Appears a wall timber was removed. Observed horizontal fence member less than 45 " from ground around entire perimeter of enclosure. Eliminate footholds less than 45 " from ground.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lounge chairs too close to pooledge. Chairs moved.
#22 · Premises: emergency telephone provided −6
When connected by Kings III to 911 operator, phone number supplied by operator is different from posted number. When stated phone number called from office it was declared disconnected.. Immediate suspension.
Jun 5, 2015 22 demerits · 6 violations
#2 · Water quality: disinfectant residual provided by −6
.No chlorine detected. Issue immediate suspension.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Provide daily written record of pH and chlorine, and weekly written record of alkalinity and cyanuric acid. Use approved test kit.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrails at both ladder and steps. Provide handrails to be secure.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Side gate broken with no latch. Operator states locks have been ordered and are due in next few days. Gate was securely locked. Doors entering pool from office are to remain locked at all times as no audible alarm is installed. Operator states doors are normally always locked.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter is stuck. Provide functioning flow meter.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No backflow protection at hose bib near pump room. Provide approved backflow device.
May 8, 2014 14 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No "check Main Drain" in record book. Corrected during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Equalizer lines plugged in two skimmers. Corrected during inspection. One weir missing.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder is loose.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Chairs too close to edge of pool. Corrected during inspection.
Jul 16, 2013 26 demerits · 9 violations
Inspector comments: ***INTENT TO SUSPEND ISSUED FOR #16****
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record cyanuric acid 1X wek
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tighten down ladder
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Replace vacuum fitting with plug
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain 5ft clear walkway around pool
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required. Maintain 3ft clear walkway around equipment.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Mark backwash line and direction of waterflow
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate should swing away from pool (INTENT TO SUSPEND)
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors should be of shatterproof construction.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “DELTA CROSSING” or State ID 2060500168). Inspection type (routine vs. follow-up) is not published in the county's data.