6demerits
DOCKSIDE CONDOMINIUMS
18889 VINEYARD POINT LN, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060500169
Latest result6 demerits
Last inspectedApr 14, 2026
Inspections on record13
On record sinceApr 22, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 22, 2014Lower is betterApr 14, 2026
Inspections & violations
Apr 14, 2026 6 demerits · 2 violations
Inspector comments: No night swimming.
Permit Restriction: Flow meter must remain operable. Flow shall be kept at 84 to 105 gpm to meet turnover and flow restriction of the return pipe. Flow greater than 119gm is a suction hazard.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. One ladder observed missing cap. Provided by operator.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed deck chairs and tables on the corners of the pool within 6’ of the pool edge. Moved during inspection.
Apr 29, 2025 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed rope for ring buoy over 50’ in length. CDI: CPO cut rope to 50’ requirement.
Apr 16, 2024 0 demerits · 0 violations
No violations were recorded for this inspection.
May 19, 2023 12 demerits · 2 violations
Inspector comments: *NOTE: The following was verified by EHS during time of inspection:
-Hayward SP32950VSP pump verified
-Blue white flow meter installed on 2’’pipe flow range at 90 gpm
-At least 10’’ on inlet side and 4’’ outlet for flow meter was verified
-Main drain, skimmer and return line- all 2’’ pipe verified
-(2)VGB2008 Aquastar A10RCFRxxx drain covers verified
-(4)VGB2008 Aquastar 6HP EQ line covers verified
-New pentair TR140C filter verified
-(6) wall or floor returns verified
-(4) skimmers verified
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. Corrected during time of inspection to 7.3
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect pool telephone number posted on signage. Corrected during time of inspection to correct number and EHS verified number was correct by calling number and contacting 911 to verify the callback number.
Apr 6, 2022 6 demerits · 2 violations
Inspector comments: There are no restrooms.
22. Relocate emergency phone sign closer to the phone; phone worked by operator noted muffled sound; phone needs to be replaced and stored in a weather-proof box.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Plastic owls present a trip hazard; removed from pool edge during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backflow line
May 5, 2021 2 demerits · 1 violation
Inspector comments: Gate on lake side opens towards pool. Cannot open other direction due to steps
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing wall bumper. Corrected during inspection
Apr 21, 2020 10 demerits · 2 violations
Inspector comments: No signature required due to COVID-19.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed pieces of the ground coming up near one of the ladders. Re caulking is needed.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
The first time 911 was called, operator could not clearly hear EHS. A new phone was provided and new phone was not able to dial 911 without holding cord into wall. Pool operator fixed phone and a proper 911 call was made.
Apr 24, 2019 14 demerits · 5 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Check and initial main drain daily
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Area of fence >4" opening, repaired during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Room needs storage shelves, maintain clear walkway around equipment, keep chemicals off floor, light & natural cross or continuous forced ventilation required
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Pipes and valves remarked during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required
May 25, 2018 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in the surface skimmers. Cleaned out during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed first to second horizontal: 37"
Observed total fence height: 42"
Fence built pre-2010.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction; lounge chairs within 6' of pool. Corrected during inspection, relocated lounge chairs.
Apr 13, 2017 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed endcaps missing on one ladder.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump/chemical room fan not working.
Apr 26, 2016 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
throw rope measured too long. Operator corrected rope to exact length during inspection
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
observed cracking on pool deck
Apr 16, 2015 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed openings in pool fence vertical members > 4".Observed broken spring on left side (facing lake) entrance gate. CPO stated that gate will remain locked and will not be an access point to pool until repaired and properly operating.Observed main entrance gate opening inward toward pool. Observed second gate that opens toward pool, but is kept locked (per CPO). Permit issued (per T.Dutcher). Sent to K.Wilson for further review.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room fan not operating. No cross ventilation present and walls are damaged.
Apr 22, 2014 8 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ends caps are missing on ladder.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence is <48", horizontal cross members in fence are <45" apart and vertical members/openings are >4".
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.Pump room fan is not continuous, no cross ventilation is present and walls are damaged.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “DOCKSIDE CONDOMINIUMS” or State ID 2060500169). Inspection type (routine vs. follow-up) is not published in the county's data.