‹ Back to search

0demerits

LANSDALE CROSSING APARTMENTS

4610 CENTRAL AVENUE, Charlotte, NC 28205
Seasonal Swimming Pool · NC permit/State ID 2060500178
Latest result0 demerits
Last inspectedJun 5, 2026
Inspections on record14
On record sinceAug 31, 2016

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Aug 31, 2016: 0Jul 13, 2017: 10May 25, 2018: 0Apr 22, 2019: 6May 6, 2020: 0Jul 13, 2021: 6May 25, 2022: 6Apr 25, 2023: 16May 24, 2023: 2May 24, 2024: 28May 31, 2024: 4Jul 18, 2025: 6Aug 13, 2025: 0Jun 5, 2026: 0
Aug 31, 2016Lower is betterJun 5, 2026

Inspections & violations

Jun 5, 2026 0 demerits · 0 violations
Inspector comments: Permit Restriction: Flow meter must remain operable. Pump must be set to 75 gpm to meet turnover and flow restriction of the combined suction pipe flow. Flow greater than 100 gpm exceeds the main drains. Suction Hazard. NO SWIMMING AT NIGHT PERMITTED.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Aug 13, 2025 0 demerits · 0 violations
Inspector comments: Conducted inspection with Trent. All items in compliance. Seasonal permit issued. Note: Filter must be changed before 2026 season, not NSF listed. Drain covers expire in 2026. Permit Restriction: Pool pump must be as close to 75gpm as possible for limitation. Pool cannot meet turnover for limiting factors and will be required to make changes if clarity issues arise. Infield plan review: Deck and new gate and fence approved. Pump Hayward SP2610x15xe VERIFIED Piping VERIFIED Return 2” Skimmer 1.5” Main Drain 1.5” Main drain 2x Paramount SDX2 VGBA2008 VERIFIED Skimmers 2 VERIFIED Returns 4 VERIFIED Filter Pentair SD-80 VERIFIED

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 18, 2025 6 demerits · 2 violations
Inspector comments: On site visit with Tret Pump Change Sand filter must be changed to an NSF Listed filter Provide electrical permit for pump change. Provide updated PDSC form Provide infield plan review form (received) Observed the following Pool Pump - Hayward SP2610x15xe Filter - Pentair Sand Dollar SD-80 (not NSF Listed) Returns - 4 Main Drain s - 2x Paramount SDX2 VGBA 2008 Skimmers - 2 Piping - Return 2", Skimmer 1.5", Main Drain 1.5" Permit Restriction: To be determined based on pump curve, request sent to Hayward.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Filter not NSF listed. .2519 Filter must be NSF listed. Flow meter not installed per manufacturer instructions. .2518(g) Install flow meter per manufacturer requirements.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no exhaust in chemical storage area. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.

View this inspection on the county portal ›

May 31, 2024 4 demerits · 1 violation
Inspector comments: No night swimming.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Minor deck damage near right side of shallow end of the pool. Observed some coping damaged near right side of pool at 6ft marker. REPEAT VIOLATION Previous violation corrected.

View this inspection on the county portal ›

May 24, 2024 28 demerits · 5 violations
Inspector comments: No Night swimming. Permit denied. Once all 4 and 6 point demerit items are in compliance call 980-314-1620 to pay the $100 re-inspection fee. Then call Sr. EHS A. Hall to reschedule the inspection.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed drains were not fully visible during inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH above 7.8.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy with rope deteriorated and flaking around the edges.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed deck drains popping up on deck near emergency equipment. CDI: Drains fixed to be flush.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no dialing instructions for phone.

View this inspection on the county portal ›

May 24, 2023 2 demerits · 1 violation
Inspector comments: NIGHT SWIMMING NOT PERMITTED. *Note: EHS accidentally forgot to change status code from Q to A when originally completing inspection paperwork. Original inspection entry was deleted and re-entered with the correct status code, so EHS was unable to obtain PIC signature on this form.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. - No air gap observed for backwash pipe. - CDI - CPO cut pipe to create a one inch air gap.

View this inspection on the county portal ›

Apr 25, 2023 16 demerits · 4 violations
Inspector comments: Contact health department (Katie Rudisill 704-309-5494) to obtain approval for NSF automatic chlorinator prior to installation. Once NSF automatic chlorinator approved and installed, contact environmental health front desk (980-314-1620) to request a reinspection. NIGHT SWIMMING NOT PERMITTED.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Observed cyanuric acid listed as 200ppm daily on records. Lower cyanuric acid levels to 100ppm or below. CPO unable to test cyanuric acid and provide a ppm value during inspection. Ensure correct way to measure cyanuric acid with test kit is being followed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Observed body hook attached to 6ft long pole. - CDI - PIC attached body hook to 12ft long pole during inspection.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Observed installed saltwater chlorinator to be malfunctioning; light flashing that indicates cell needs to be inspected. CPO stated chlorine is being hand fed directly into pool daily. Install an NSF approved automatic chlorinator. Permit denied until chlorinator installed.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. - No air gap observed for backwash pipe. Create an air gap.

View this inspection on the county portal ›

May 25, 2022 6 demerits · 2 violations
Inspector comments: No night swimming.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering Sign was not in 4 inch lettering. CDI - 4 inch lettering sign obtained.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap for back wash pipe. CDI - Pipe cut

View this inspection on the county portal ›

Jul 13, 2021 6 demerits · 2 violations
Inspector comments: Observed pH at 8.0 at beginning of inspection. CDI, pH level corrected to 7.4. Pool in compliance.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed openings on fence from forced entry. CDI, openings closed and repaired during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemicals stored on floor at pump room. CDI, items relocated during inspection.

View this inspection on the county portal ›

May 6, 2020 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED. POOL HAS AQUASTAR 6HP EQ LINE DUMMY COVERS ON PLUGGED EQ LINES. THESE COVERS EXPIRE SEPTEMBER 2021. WHEN THE CURRENT COVERS EXPIRE, NEW EQ COVERS OR POOL WALL PLUGS MUST BE INSTALLED. IF THE LINES ARE PLUGGED, THEY SHOULD BE PLUGGED AS PER STATE RECOMMEDATIONS, WHICH INVOLVES PLUGGING AT THE WALL, PLUGGING AT THE THE EQ LINE IN THE SKIMMER, AND REMOVING THE WATER FROM THE LINE BEFORE PLUGGING. THE MAIN DRAINS WILL ALSO EXPIRE JULY 2021 AND WILL REQUIRE REPLACEMENT. WHEN THESE ITEMS ARE REPLACED, PDSC PAPERWORK WILL HAVE TO BE SUBMITTED TO THE HEALTH DEPARTMENT FOR APPROVAL. PERMIT ISSUED. STICKER ISSUED. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. “issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 22, 2019 6 demerits · 2 violations
Inspector comments: PDSC form was verified during inspection. Equalizer covers were noted during the inspection however equalizer lines were plugged permanently with concrete. Per state guidance, equalizer covers should be removed after they expire and a smooth coating applied so that it provides a smooth surface for bathers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed gap between fencing greater than 4" (measured at 4.5"-5"). Fencing is in good repair surrounding the majority of the pool. CPO informed. Suggestion to repair fencing.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed pump room height less than 7 ft. Observed liquid chemical stored on dry chemical in pump room. Observed no separate chemical storage room. Chemicals stored in pump room.

View this inspection on the county portal ›

May 25, 2018 0 demerits · 0 violations
Inspector comments: Looks Great!

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 13, 2017 10 demerits · 2 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed one three foot depth marker with faded paint. Marker is still legible but should be repainted.
#22 · Premises: emergency telephone provided −6
During emergency phone line test, phone cut out for approx 1second during the conversation. EHS was able to complete the emergency call. Ensure that the phone stays in good working order. Phone was clear and loud throughout the rest of the call.

View this inspection on the county portal ›

Aug 31, 2016 0 demerits · 0 violations
Inspector comments: Observed good water chemistry. Emergency phone functioning well. Piping labeled. Vac-Alert now installed such that the guage can be read and it can be reset. Both equalizer lines now pluged. Operator filled out an updated PDSC form. Form approved. Permit will be issued online at Meckpools.Charmeck.org in 3-5 business days. Please go online to print a copy of the permit and post in the pool area.

No violations were recorded for this inspection.

View this inspection on the county portal ›