‹ Back to search

4demerits

EDGEHILL TERRACE APARTMENTS

1030 EDGEHILL ROAD, Charlotte, NC 28207
Seasonal Swimming Pool · NC permit/State ID 2060500185
Latest result4 demerits
Last inspectedJun 18, 2026
Inspections on record13
On record sinceJun 4, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0510 Jun 4, 2014: 10Apr 23, 2015: 4Apr 29, 2016: 10Jun 8, 2017: 4Apr 26, 2018: 10May 1, 2019: 4Jun 9, 2020: 10Apr 28, 2021: 10May 24, 2022: 10May 9, 2023: 0May 22, 2024: 10May 29, 2025: 6Jun 18, 2026: 4
Jun 4, 2014Lower is betterJun 18, 2026

Inspections & violations

Jun 18, 2026 4 demerits · 1 violation
Inspector comments: PERMIT ISSUED POOL IS NOT PERMITTED FOR NIGHT SWIMMING FLOW METER MEASUREMENT: 40 GPM INSPECTOR VERIFIED 2.25 MOTOR ON A 1.5 HP PUMP AND VERIFIED DRAIN COVERED MATCH PDSC FORM: OBSERVED 2 AQUASTAR A10RCFR101 2017
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches shall be 54" in height. Observed latch measuring 49 inches in height. CDI: CPO adjusted gate latch to measure 54 inches in height.

View this inspection on the county portal ›

May 29, 2025 6 demerits · 1 violation
Inspector comments: No night swimming permitted Drain covers and filtration pump verified during inspection Permit issued
#22 · Premises: emergency telephone provided −6
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Kings 3 phone was not able to connect to 911 operator. CDI - The phone signal was reset and it was able to connect to 911 during inspection.

View this inspection on the county portal ›

May 22, 2024 10 demerits · 2 violations
Inspector comments: No night swimming. All 4 and 6 point demerit items in compliance by end of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope longer than 30’. CDI: Rope measured and cut during visit.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches shall be 54" in height. Observed gate latch at 50” in height. CDI: Gate latch adjusted.

View this inspection on the county portal ›

May 9, 2023 0 demerits · 0 violations
Inspector comments: No violations noted. NIGHT SWIMMING NOT PERMITTED.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 24, 2022 10 demerits · 3 violations
Inspector comments: NO NIGHT SWIMMING.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Floating debris on skimmers. CDI
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter was not operational. CDI
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. No backflow preventer installed. CDI

View this inspection on the county portal ›

Apr 28, 2021 10 demerits · 2 violations
Inspector comments: Night Swimming has not been approved. Kara Rhew was the Pool Operator onsite during the inspection. No Signature was given due to COVID 19. Issuance of permit by this Department does not negate meeting requirements of Executive Order 195 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. This was corrected and the pH was raised to 7.2.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter bobber not properly functioning. This was corrected and the bobber was repaired.

View this inspection on the county portal ›

Jun 9, 2020 10 demerits · 2 violations
Inspector comments: Due to COVID19 pandemic no signature occurred. CPO Kara was present during inspection. Night swimming not approved until return visit occurs for approval.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. - Observed pH at 7.0 at the start of the inspection. CDI- CPO brought pH to 7.6 by the end of the inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed leaf and dirt debris on pool floor. CDI- CPO cleaned debris by the end of the inspection.

View this inspection on the county portal ›

May 1, 2019 4 demerits · 2 violations
Inspector comments: PDSC form reviewed and verified during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. No separate chemical storage room not provided.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments. No restroom accessible less than 300 feet.

View this inspection on the county portal ›

Apr 26, 2018 10 demerits · 3 violations
Inspector comments: **Cut landscaping back from body hook, makes it awkward to get to it. **Submit new PDSC form for correct motor hp on pump. PDSC form says 1.5hp, pump says 2.25hp **Keep an eye on the emergency phone. New jack may need to get wired in, phone crackly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate scrunched down, where trees/shrubs are. Keep second (landscaper) gate with locks on both sides or repair the one side so the gate cannot be lifted off its bracket and opened
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Observed pool open after dusk per sign. No night swimming approved until sufficient light can be determined. Areas that need adequate lighting are pool deck, main drains, floor of pool, emergency equipment and emergency phone.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no accessible restrooms within 300 feet.

View this inspection on the county portal ›

Jun 8, 2017 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer to be blocked with leaves.Keep skimmers free of debris.

View this inspection on the county portal ›

Apr 29, 2016 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope connected to ring buoy at 59 Feet. Provide throw rope at 30 feet. Rope was corrected to 30 feet during inspection.
#18 · Premises: lifeguards present or warning signs posted −4
Observed 'warning no lifeguard on duty' sign with lettering less than 4 inches. Provide sign with minimum 4 inch lettering and exact wording. CDI- new sign with 4 inch lettering and exact wording was posted during inspection.

View this inspection on the county portal ›

Apr 23, 2015 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Repair pool deck where ladder pole connect into pool deck. Observed some chipping/breaking or concrete around base of pole on pool deck. General Comment: Monitor pH closely! Continue to clean pool floor. Eric Rhew present at time of inspection.

View this inspection on the county portal ›

Jun 4, 2014 10 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder missing a step bolt. Replace.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some areas of chain link fence with greater than 2.25 gaps. Some areas are very loose and a person cound get through. Repair fence.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No flow meter. Provide. INTENT TO SUSPEND ISSUED. Eric Rhew present.

View this inspection on the county portal ›