‹ Back to search

0demerits

EDGEWATER CONDOMINIUMS

300 NORTHWEST DRIVE, Davidson, NC 28036
Seasonal Swimming Pool · NC permit/State ID 2060500186
Latest result0 demerits
Last inspectedApr 27, 2026
Inspections on record14
On record sinceApr 17, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Apr 17, 2014: 2Apr 1, 2015: 14Apr 27, 2016: 4May 11, 2017: 4May 22, 2018: 2Apr 18, 2019: 28Apr 21, 2020: 6Apr 26, 2021: 2May 10, 2022: 10Apr 20, 2023: 12Apr 30, 2024: 0Apr 21, 2025: 12Apr 22, 2026: 14Apr 27, 2026: 0
Apr 17, 2014Lower is betterApr 27, 2026

Inspections & violations

Apr 27, 2026 0 demerits · 0 violations
Inspector comments: NO NIGHT SWIMMNG. PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW SHALL NOT EXCEED 119 GPM DUE TO DRAIN COVER FLOW RESTRICTION. BARRIER IS MADE UP OF RETAINING WALL MEASURED FROM OUTSIDE OF SWIMMING POOL ENCLOSURE. 22. Observed some static on emergency phone when calling 911. REHS was able to communicate with operator to verify address and phone number. Recommended checking phone and/or phone line for issues.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 22, 2026 14 demerits · 3 violations
Inspector comments: Permit denied. Correct items and request reinspection at 704-617-2897
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
.2535(2) Main drains must be clearly visible from the pool deck. Observed pool water to be cloudy and main drains were not clearly visible.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface and pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers.

View this inspection on the county portal ›

Apr 21, 2025 12 demerits · 2 violations
Inspector comments: FLOW METER MUST REMAIN OPERABLE. FLOW SHALL NOT EXCEED 119 GPM DUE TO DRAIN COVER FLOW RESTRICTION. BARRIER IS MADE UP OF RETAINING WALL MEASURED FROM OUTSIDE OF SWIMMING POOL Facility has added an erosion feeder and now uses solid chlorine tablets. No Night Swimming. Permit issued.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. CDI: Pool pH 7.6 by end of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed ring buoy ropes disintegrating when touched. CDI: Ring buoy replaced during inspection.

View this inspection on the county portal ›

Apr 30, 2024 0 demerits · 0 violations
Inspector comments: NOTE: - PIC: Mr. Brian Pridmore present during inspection permit. PERMIT RESTRICTION: Flow meter must remain operable. Flow shall not exceed 119 GPM due to drain Cover Flow restriction. Barrier is made up of retaining wall measured from outside of swimming pool.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 20, 2023 12 demerits · 4 violations
Inspector comments: PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. FLOW SHALL NOT EXCEED 119 GPM DUE TO DRAIN COVER FLOW RESTRICTION. OBSERVED NEWLY INSTALLED DRAIN COVERS AQUASTAR A10RCFR101 VGB 2017. FLOW MEASURED AT 90GPM.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pool fence less than 48” in a couple of areas.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed stuck flow meter. CDI
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap for backwash
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. No backflow preventer on hose bib

View this inspection on the county portal ›

May 10, 2022 10 demerits · 3 violations
Inspector comments: Note: Observed 2x hand railings beginning to come loose at entrance of pool, secure. EHS confirmed PDSC information. Operator Kara Gilchrist on site during inspection. Permit issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed no throw rope attached to ring buoy to begin inspection. CDI- Operator tied throw rope to correct length during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash pipe.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow prevention device on hose bib.

View this inspection on the county portal ›

Apr 26, 2021 2 demerits · 1 violation
Inspector comments: Kara Gilchrist present during inspection. Verified pumps and main drain covers. Equalizers are plugged per state regs. The pool had some brown staining from being plastered two years ago on some areas of the pool floor.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventer on hose bib.

View this inspection on the county portal ›

Apr 21, 2020 6 demerits · 1 violation
Inspector comments: .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool chairs less than 6 ft around pool. Chairs were moved back. No signature required due to COVID-19.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy measuring 46.2 ft. A new rope was provided and measured 50ft.

View this inspection on the county portal ›

Apr 18, 2019 28 demerits · 8 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Keep pool walls & floor clean & free of debris
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Keep baskets free of debris
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence/brick wall does not meet 48" height rule or foot hold rule
#22 · Premises: emergency telephone provided −6
Phone number too faded to read, remarked number inspection
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Gage & flow meter repaired during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirror to be of shatterproof construction
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Back flow preventer required on hose bib

View this inspection on the county portal ›

May 22, 2018 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed backwash pipe with no airgap.

View this inspection on the county portal ›

May 11, 2017 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed sections of brick fence to be <48" in height.

View this inspection on the county portal ›

Apr 27, 2016 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Keep furniture >6' from pool edge and observed several cracks on the pool decking and the expansion joint at the coping - needs re-caulked

View this inspection on the county portal ›

Apr 1, 2015 14 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed sections of brick fence to be < 48" in height.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed small fractures in concrete on pool deck.
#22 · Premises: emergency telephone provided −6
Observed 911 sign posted without location phone number. CDI by adding phone number to sign.

View this inspection on the county portal ›

Apr 17, 2014 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan does not work in pump room and walls are damaged. Also no cross ventilation is present.

View this inspection on the county portal ›