EMERALD POINT
9805 EMERALD POINT DR, Charlotte, NC 28278
Seasonal Swimming Pool · NC permit/State ID 2060500192
Latest result8 demerits
Last inspectedApr 27, 2026
Inspections on record13
On record sinceApr 30, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 30, 2014Lower is betterApr 27, 2026
Inspections & violations
Apr 27, 2026 8 demerits · 3 violations
Inspector comments: Facility does not have a separate chemical storage room due to being constructed prior to pool rules. Chemicals are stored in equipment room.
Permit Restriction: Flow meter must remain operable with flow not to exceed 188 gpm due to drain cover flow restriction. Suction Hazard. Main drain valve required locked in place. See picture attached to PDSC form.
Main drain covers expire: 04/05/2031
Equalizer covers expire: 04/05/2031
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. EHS observed that facility did not have no lifeguard on duty sign posted. CDI- CPO provided sign and posted.
-4-
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533 (d) Pump room floor shall be kept dry and free of standing water. Observed floor of equipment room wet due to minor leak.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. EHS observed no air gap at backwash line.
-2-
Apr 11, 2025 10 demerits · 3 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed eyeball fitting missing. CDI, new eyeball fitting provided.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. No lifeguard on duty sign was not posted. CDI sign was posted
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash line.
Apr 18, 2024 6 demerits · 2 violations
#18 · Premises: lifeguards present or warning signs posted −4
No lifeguard on duty sign was not posted. CDI sign was posted
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap in backwash.
Apr 20, 2023 10 demerits · 3 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED
TDH PROVIDED, FLOW METER MUST REMAIN OPERABLE NOT TO EXCEED 168 GPM DUE TO DRAIN FLOW RESTRICTION
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Skimmers dirty with debris, CDI- Cleaned
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
Depth markers was fading and not visible. CDI- New depth markers spray painted.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.
No air gap on backwash pipe
Apr 26, 2022 0 demerits · 0 violations
Inspector comments: no demerits taken.
No violations were recorded for this inspection.
Apr 12, 2021 8 demerits · 2 violations
Inspector comments: Pre-permit inspection complete. Pool permit issued. No night swimming.
#4 · Water quality: water temperature of heated pool −6
Observed pH 7.1 upon arrival. CDI- pH corrected and observed at 7.5 before leaving.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Facility does not have a separate chemical storage room due to being constructed prior to pool rules. Chemicals are stored in equipment room. .2533 (e) Provide continuous forced ventilation or cross ventilation in pump room. Equipment room does not have any forced mechanical or cross ventilation.
.2533 (d) Pump room floor shall be kept dry and free of standing water. Observed floor of equipment room wet due to some minor leaks from fill line and near pump.
Apr 27, 2020 24 demerits · 7 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Bridge/flashing above skimmer box is rusting
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
no rope set up at start of inspection. Operator cut new rope and installed safety floats
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy in poor condition. corrected during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence has 6" opening. pre 2010 construction
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
no cross ventilation or forced ventilation
#27 · Equipment room: filter backwash discharged through an air gap −2
no air gap for backwash
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
chairs obstruct 5' of clear walking space around ladder. Moved during inspection
Apr 24, 2019 22 demerits · 8 violations
Inspector comments: PDSC form verified. Pump data plate missing.
There are decorative footholds in the fence. Pre-2010 pool.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. No rope setup upon arrival. Safety rope installed during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence has 6" openings. Pre-2010 pool.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs 4ft from pool. Moved.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
Sign on site had lettering less than 1" and verbiage wasn't correct. A standarad pool rules sign was hung during inspection that met requirements.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. No ventilation in pump/chemical room.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(f) At least one sink, one toilet, one urinal is required for men's restroom. Urinal is out of order.
.2626(l) Provide toilet paper and dispensers in restrooms. Observed no toilet paper in women's restroom.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide backflow protection on hose bibbs in the restrooms.
Apr 19, 2018 4 demerits · 2 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
LIFEGUARD NOT REQUIRED.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Ground minorly wet in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap present for backwash.
Apr 25, 2017 8 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence on brick wall has spacing greater than 4 inches (5.5 inches). Fence was built prior to 2010. No permit action taken.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No ventilation in chemical room - Provide ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash pipes. Provide air gap.
May 3, 2016 16 demerits · 6 violations
Inspector comments: #17 Deck crack/ chunk of missing concrete @ old spa site. ** Fill.
POOL PERMIT CAN BE ISSUED
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some scum on pool wall tiles. ** Clean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Vertical members of fence spaced 6". ** Maximum spacing allowed is 4". Roof of pool house (particularly @ junction with wrought iron fence above pool deck) does not allow 48" barrier around entire pool. ** See .2528 Fences.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No forced air or cross ventilation in equipment/ chemical room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash lines (2): one even w/sump & the other extends down into sump. ** Backwash water should discharge through complete air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Shower missing handle. ** Install.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bibs (1 in equipment/ chemical room & 2 in women's restroom) have no backflow protection. ** Install vacuum breakers.
Apr 27, 2015 24 demerits · 8 violations
Inspector comments: 22 - General Comment: Pool phone not located directly next to phone. Signage not visible if moved on deck to different location.No Night Swimming. Lighting on deck not provided. Permit will be posted online within 3 days.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on pool floor. Keep clean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence height at house at 36"; fence at 47". >4" between horizontals and footholds on fence. Decorative footholds in between horizontals. Fence/gate must meet requirements of .2528.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Damage at deck at 8 ft. No trip hazard.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
3 skimmers on pool with vacuum not plumbed. Provide vacuum cleaning system.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Ventilation not provided in pump room. Provide cross ventilation or forced continuous ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash pit. Provide air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Lighting blinking on and off in the restrooms. Repair lighting.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention devices on hose bibs. Provide backflow prevention device on all hose bibs.
Apr 30, 2014 8 demerits · 3 violations
Inspector comments: 17. GENERAL COMMENTS:Small area of damaged decking at 8FT end of pool. Repair damaged area of pool deck.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Vertical fencing around pool more than 4 inches; access from roof of building. Fencing measured at 6 1/4 inches.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No cross ventilation or forced air ventilation in equipment/ chemical room. Provide cross ventilation in chemical storage/ equipment room.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Lighting in women's restroom is operational, but not completely lit. Cleaning of restroom fixtures needed, provide toilet paper.