2demerits
GATES AT QUAIL HOLLOW
7040 MEETING ST, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060500228
Latest result2 demerits
Last inspectedApr 22, 2026
Inspections on record13
On record sinceApr 22, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 22, 2014Lower is betterApr 22, 2026
Inspections & violations
Apr 22, 2026 2 demerits · 1 violation
Inspector comments: No night swimming.
Permit Restrictions: flow meter must remain operable. Flow shall not exceed 119 GPM due to drain cover restrictions. Suction hazard.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventer on hose bib on pool deck
Apr 11, 2025 8 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed fraying ring buoy throw rope. CDI-CPO replaced with new ring buoy in good repair.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed backwash pipe directly piped into drain inside pump room.
Apr 23, 2024 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed minor plant litter at surface of pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed a gym door that can be unlocked with no self closing door. Audible alarm had been added to door prior to inspection. CDI- CPO added door spring to allow door to self close and self latch, in addition to audible alarm.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at the backwash.
May 5, 2023 10 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed a gym door that can be unlocked with no self closing latch or audible bell. CDI-PO added audible bell.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed 1 warning sign with 3.75” lettering. CDI-PO added a new sign with 4” lettering.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at the backwash.
Apr 11, 2022 6 demerits · 2 violations
Inspector comments: No night swimming permitted.
Pool hours are from dusk til dawn per operator.
75 GMP
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No records provided for chemicals on site. CDI for today’s chemical. Determined that the pen in room was not working.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors in bathroom were not shatterproof.
Apr 20, 2021 10 demerits · 4 violations
Inspector comments: No night swimming permitted.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI, calibrated during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Observed light now working. CDI, replaced during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap in men's restroom.
Apr 28, 2020 16 demerits · 5 violations
Inspector comments: Pool inspection was conducted with Pierce Sawyer.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Ring Buoy rope was greater than 50 ft before being cut by CPO. Rope of Ring Buoy is now 30 ft per it's PDSC form requirements.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed No Life Guard on Duty signage containing wording that is less than 4 inches. CPO added a new No life Guard on duty with wording that meets code with at least 4 inch wording.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Labels and Arrows were faint and missing on some of the pipes on the filtration system. CPO shall remark pipes to better detail flow of filtration.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Post a shower sign visible upon entrance to the pool Shower sign was posted in area that was not easily viewed from the entrance of the pool.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors in bathroom were not shatterproof.
Apr 29, 2019 16 demerits · 5 violations
Inspector comments: PDSC form verified.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. Up to 7.2 by end of inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter was repaired during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(i) Water in restrooms shall not exceed 110 F. Water in restrooms is at 113F.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2626(c) Floor drains shall be provided in restrooms. No hose bibbs available.
Apr 11, 2018 6 demerits · 3 violations
Inspector comments: PDSC and VGB information verified.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Water observed on floor of chemical storage room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on back wash discharge.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no hose bibs in restrooms.
Apr 28, 2017 18 demerits · 6 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Maintain pool floor clean. Observed floating debris and debris on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Maintain skimmer baskets clean. Observed debris inside skimmer baskets.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Maintain flow meter in good condition. Observed flow meter inoperable at arrival. Repaired by departure.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Maintain valves and pipes clearly labeled. Observed faded labels on piping. These were re-labeled while onsite.
#27 · Equipment room: filter backwash discharged through an air gap −2
Maintain an air gap for backwash. Observed no air gap present.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Maintain water temperature in restrooms at or below 110F. Observed at 112F.
Apr 13, 2016 4 demerits · 2 violations
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed fan not functioning in chemical room. Fix fan to provide ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
(2513). Observed no air gap for backwash pipe.
Apr 9, 2015 8 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on the pool floor. Maintain clean.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Observed missing end cap on one pool ladder. Maintain ladders in good repair.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap for backwash in the equipment room. Provide air gap for back washing.
Apr 22, 2014 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
cap missing on ladder.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “GATES AT QUAIL HOLLOW” or State ID 2060500228). Inspection type (routine vs. follow-up) is not published in the county's data.