Latest result20 demerits
Last inspectedMay 15, 2026
Inspections on record10
On record sinceMay 26, 2017
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 26, 2017Lower is betterMay 15, 2026
Inspections & violations
May 15, 2026 20 demerits · 6 violations
Inspector comments: No night swimming permitted.
Electrical conduit on the deck is outside of 6’’ required Pool deck clearance. Recommended keeping covered with pool furniture to avoid hazard.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladder closest to fence loose. Tighten ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding required length. CPO cut rope to required length during inspection. 37’’ to 35’’.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 inches more under the fence by the parking area.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Flow meter be capable of measuring 1.5 times the design flow rate. Observed flow meter unable to carry 1.5 times the design flow rate.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at back wash. REPEAT VIOLATION
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Observed no shower at pool during inspection.
Jun 17, 2025 24 demerits · 6 violations
Inspector comments: NO NIGHT SWIMMING.
NOTE: Gate swings towards pool due to ramp (Pool is pre-2010) If changes to fencing or decking are made gate will need to be corrected.
PERMIT RESTRICTION: TABLES OR CHAIRS MUST BE PLACED OVERTOP BOTH SETS OF ELECTRICAL PIPING LOCATED ON DECK AT ALL TIMES TO PREVENT TRIP HAZARDS.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit with expired reagents. CPO provided test kits with new reagents.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed minor debris in skimmer basket. CPO dumped skimmer basket.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed ladder closest to fence loose. Tighten ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding required length. CPO cut rope to required length during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed 2 sets of electrical piping sticking up from deck. Piping was approximately 12 inches tall. CPO placed tables over electrical piping to prevent trip hazard. See general comment box for added permit restriction.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed no “adults should not swim alone” signage. CPO added signage during inspection.
Jul 17, 2024 18 demerits · 3 violations
Inspector comments: Fernando Barreto present for inspection.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Chlorine measures 0.0 ppm
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH 7.1
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Operator stated skimmers and drain covers have been replaced recently. PDSC form has not been updated with MCHD.
May 18, 2023 2 demerits · 1 violation
Inspector comments: Permit issued. No night swimming.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at back wash. REPEAT VIOLATION
Apr 26, 2023 22 demerits · 5 violations
Inspector comments: Observed minor damage to pool surface on floor near left side main drain. Have repaired in off season prior to next year’s permitting.
No night swimming.
Fence does not meet current code for spacing of horizontals on the barrier. If fence is replaced, it must be brought to current code.
Once all 4 and 6 point demerit items are in compliance, call 980-314-1620 to pay the $100 re-inspection fee. Then call/email Sr. EHS Alexandra Hall to schedule a re-inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH greater than 8.4.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope longer than 35 ft. CDI: Rope cut to proper length.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed no sign indicating “Adults should not swim alone”.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not operational.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at back wash.
May 26, 2021 0 demerits · 0 violations
Inspector comments: Facility in compliance. Observed evidence of bent vertical bars on sections of the fence. PIC states bent bars are from tenants trying to force their way in to the pool. PIC states daily inspections are conducted to make sure bars are straight and fixed. PIC states he will add mesh to the fence in the future to prevent forced entries. EHS advised PIC to let county know when facility adds mesh to ensure compliance.
No violations were recorded for this inspection.
Jun 5, 2020 8 demerits · 3 violations
Inspector comments: 44" HORIZONTALS ON FENCE IN SOME AREAS-PRE-2010; CLEANOUTS LOCATED ON DECK AWAY FROM REQUIRED POOL CLEARANCE AREA
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
SOME LITTER ON POOL FLOOR -- VACUUM/CLEAN
#27 · Equipment room: filter backwash discharged through an air gap −2
NO AIR GAPS @ BACKWASH
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
NO HOSE BIBS AVAILABLE
May 24, 2019 2 demerits · 1 violation
Inspector comments: PDSC form reviewed and verified during inspection.
CPO present for inspection.
No night swimming. Pool hours 10am-dusk.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
.2626(c) Restroom floor shall be sloped to drain.
No floor drain in pool restroom.
Jun 14, 2018 6 demerits · 2 violations
Inspector comments: 12. Several inlets no longer functional and plugged -- Circulation appears adequate.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Check water daily with test kit -- Do not rely on feeder.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap or paper towels in restroom -- Supply
May 26, 2017 12 demerits · 3 violations
Inspector comments: **PERMIT APPROVED**
--POOL MAY OPEN FOR OPERATION
#5 · Water quality: daily written records of water quality and test kit kept on site −4
PROVIDE DAILY RECORS SHEET -- NONE ON HAND (SUPPLIED)
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
THROW ROPE TOO LONG -- CORRECTED
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
NO TOILET PAPER IN RESTROOM -- SUPPLY