14demerits
DOUBLETREE SUITES BY HILTON
6300 CARNEGIE BLVD, Charlotte, NC 28211
Seasonal Swimming Pool · NC permit/State ID 2060500237
Latest result14 demerits
Last inspectedApr 16, 2026
Inspections on record15
On record sinceApr 16, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 16, 2014Lower is betterApr 16, 2026
Inspections & violations
Apr 16, 2026 14 demerits · 4 violations
Inspector comments: Feature is missing several tiles, items must be replaced prior to permit issuance of 2027 pool season.
EHS recommend to re-paint etched “no diving” and depth markers with a contrasting color
EHS recommends to keep Stingl operational
EHS observed records not being filled out past August 2025. EHS advises records should be filled out for the duration of operating season.
EHS observed all lights used for night swimming operational. Night swimming is approved.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 inch gap under maintenance gate in back corner. Pool was built in 1984
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone able to connect to 911 but was not ringing back when EHS called phone number. CPO switched out the phone, EHS observed phone audibly ring.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Observed chemicals stored in pump room. Pool was built in 1984
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Unable to locate hose bib for restrooms.
Apr 14, 2026 38 demerits · 10 violations
Inspector comments: Feature is missing several tiles, items must be replaced prior to permit issuance of 2027 pool season.
EHS recommend to re-paint etched “no diving” and depth markers with a contrasting color.
Re-inspection fee required. Call main office at 980-314-1620 once all 4 and 6 point demerits are corrected.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed minor debris in skimmer baskets. CPO dumped during inspection
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 2 missing inlet covers and 1 inlet cover missing the direction flow piece. Permit denied
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located. Observed body hook mixed in with pool cleaning equipment on top of brick wall. CPO moved body hook to hooks on front of brick wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 inch gap under maintenance gate in back corner. Pool was built in 1984
.2537(b) All gates and doors shall be self-closing, self-latching. Observed main gate latch not catching consistently when gate is used. Permit denied.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed “warning no lifeguard on duty” signage faded. Permit denied.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed signage at emergency with address stating “Carnegie bv” 911 operator stated they have Morrison bv on file. Google Maps is showing 6300 Carnegie bv and 6300 Morrison bv are the same place where the pool is located. CPO changed address on signage to match 911.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed both flow meters not operational. Permit denied.
Observed heavy leaking in pump room underneath pipes.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Observed chemicals stored in pump room. Pool was built in 1984
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed piping in pump room without arrows indicating direct of flow.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Unable to locate hose bib for restrooms.
Apr 22, 2025 16 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing or damaged skimmer basket. Observed one broken skimmer basket
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Provide at least one handrail on steps. Observed loose handrail. CDI-tightened
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed loose hinge on left front gate. CDI-tightened, check regularly that it is self-latching.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone did not ring back. CDI-phone exchanged, phone now needs to be dialed 911. Sign changed to reflect not auto-dial
Apr 10, 2024 18 demerits · 4 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH at 7.0. CDI - pH was increased to 7.2.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed weir missing in one skimmer. CDI - Weir was added to skimmer.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed end cap missing on ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 40 ft. CDI - Rope was shortened to 38ft.
Apr 13, 2023 0 demerits · 0 violations
Inspector comments: Pool is approved for 2023 season. Night swimming approved (2022 inspection).
No violations were recorded for this inspection.
Apr 14, 2022 12 demerits · 4 violations
Inspector comments: Observed pool lights working today. Pool is permitted for night swimming. See approval from 2021.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Provide at least one handrail on steps.
Tighten handrail at steps
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
Rope was 33’. Corrected to 38’
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels.
Piping not labeled
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.
No air gap on discharge
Apr 15, 2021 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed no end cap on one of three ladders. -2-
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed direct connection between end of piping and drain. -2-
May 28, 2020 4 demerits · 1 violation
Inspector comments: Inspection completed with Alain Cabrera
issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.”
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed deck with cracks that are less than 1/2” inch but in need of repair.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed tiles closer to pool edge that are heavily cracked with large dents and cracks. CDI cracks filled with puddy.
Apr 11, 2019 10 demerits · 2 violations
Inspector comments: Facility is approved for night swimming as of 2018.
PDSC information verified during inspection.
Chlorinator verified during inspection.
Jerry Lucas present for inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rop length for ring buoy at 41 ft (38 required). CDI: Rope length cut down to 38 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed both entry gates to pool deck to not be self closing if opened fully. CDI: CPO placed screws in the latching mechanism to prevent gate from opening fully. After placement, gates were fully self closing and self latching.
May 21, 2018 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
one weir missing. CDI
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
2 no diving markers missing at each end of pool. CDI both painted on during inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Both lights were loose. CDI Both tightened.
Apr 20, 2018 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmers in need of cleaning.
Apr 11, 2017 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed a section of the fence measuring at 7 inches from the ground to a horizontal bar of the fence. CDI- Operator applied a few bricks to the area and brought the distance within 2 inches.
NOTE: Operator stated the facility will make a more permanent fix by pouring concrete or using heavy river stone.
Apr 25, 2016 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
Observed pH at 7.0. Corrected onsite tom 7.4.
Apr 1, 2015 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose handrail. CDI- tightened.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck is not continuous and 5 feet around pool.
Apr 16, 2014 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “DOUBLETREE SUITES BY HILTON” or State ID 2060500237). Inspection type (routine vs. follow-up) is not published in the county's data.