2demerits
HAMPTON INN CORNELIUS
19501 STATESVILLE ROAD, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060500244
Latest result2 demerits
Last inspectedMay 20, 2026
Inspections on record15
On record sinceJun 17, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 17, 2014Lower is betterMay 20, 2026
Inspections & violations
May 20, 2026 2 demerits · 1 violation
Inspector comments: Inspection completed with CPO, Eugene Kazimirau
- Salt for chlorine
- 5% Flow meter has been installed and approved
- CPO logs begin today
- NIGHT SWIMMING ALLOWED
Permit Restriction - Flow meter must remain operable. Flow required at 67gpm to 74gpm to meet turnover and flow restriction of the filter.
New pump verified: Pentair SuperfloVST 342002, 2.2 THP
Flow meter, drain covers, filter, returns and disabled equalizers verified.
Permit issued
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F.
Observed 120 degree hand sink water in the restrooms
Apr 29, 2026 6 demerits · 2 violations
Inspector comments: New variable speed pump was installed and grounded on 3/20/26: PENTAIR SUPERFLO VST ALM
PDSC form has the pump listed as STA-RITE P2RA5YEL
Flow meter appears to be moving just above 0gpm
Pool uses salt as primary form of chlorination
Permit denied due to:
.2518(h) Provide approved pump in good repair.
Pool requires re-inspection prior to opening. An updated PDSC form and $100 fee must be submitted and approved before scheduling.
(980-314-1620)
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(i) Water in restrooms shall not exceed 110 F.
Observed 120 degree water in the lobby restroom hand sinks.
Jun 6, 2025 0 demerits · 0 violations
Inspector comments: Approved for night swimming with verification - 7/1/2022
No violations noted during inspection
No violations were recorded for this inspection.
Jun 6, 2025 6 demerits · 1 violation
Inspector comments: Pool permit denial due to chlorine reading of 0ppm in swimming pool.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0ppm in swimming pool.
May 15, 2024 0 demerits · 0 violations
No violations were recorded for this inspection.
May 16, 2023 0 demerits · 0 violations
Inspector comments: Note: EHS discussed condition of ring buoy ropes, starting to show signs of fraying. CPO stated they will look into getting new ones for next pool season.
EHS confirmed all PDSC info (pump, drain covers, equalizer covers), as per approved PDSC form.
This facility has been permitted for night swimming (last verification 7/1/2022), EHS confirmed lights are operational.
Permit issued.
No violations were recorded for this inspection.
Jun 24, 2022 0 demerits · 0 violations
Inspector comments: No violations noted during inspection
No violations were recorded for this inspection.
May 27, 2021 2 demerits · 1 violation
Inspector comments: This pool requested night swimming. Night swimming will be verified by EHS. Pool operator reminded that gate shall swing away from the pool prior to issuance of 2022 permit to operate.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed hose laying in bottom sump form filter backwash. CDI - Operator raised hose above the flood rim to restore air gap.
May 21, 2021 0 demerits · 0 violations
Inspector comments: Permit denied due to no measurable free chlorine in the pool. Staff stated chlorine levels fall throughout the day. Equipment must be able to handle conditions.
Note that pool gate currently swings in towards the pool. Permit not being denied due to gate this year.
To request a re-inspection, call Mecklenburg County Health Department at 980-314-1620. Pay $100.00 fee to generate a Service Request for return visit.
No violations were recorded for this inspection.
May 14, 2019 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
observed loose hand rail. Corrected during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lounge chairs within 6 ft of pool edge. Corrected during inspection.
Jun 18, 2018 8 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed greater than 4" openings between vertical members on gate. CDI-plexiglass put in place on gate to prevent footholds.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs within 6' of pool edge.
May 11, 2017 16 demerits · 4 violations
Inspector comments: Permit cannot be issued until a new PDSC form is submitted and approved.
MD = Paramount SDX retro
EQ = Waterway 640-803V Only 2 skimmers, not 3 as noted
No label on pump (STA-RITE pump)
#2 · Water quality: disinfectant residual provided by −6
Initial chlorine reading of 0. CPO raised to 3 during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck chairs <6' from the pool edge. Recommend re-caulking the coping joint
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operating
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no fan in the pump room
May 4, 2016 6 demerits · 2 violations
Inspector comments: 22. post new address/phone number sign - old sign starting to peel off.
Pool passed pre-inspection pending confirmation of pump information - PP2RA5YEL
Report received by Joe Sleeper
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Record daily maintenance and chemical addition
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required, store gas powered blower elsewhere
Apr 28, 2015 8 demerits · 2 violations
Inspector comments: Pool passed preinspection
Inspection report received by Joe Sleeper
#3 · Water quality: pool water pH −6
pH corrected to 7.2 during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Natural cross or continuous forced ventilation required
Jun 17, 2014 16 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope shall be at correct length. Observed two ring buoys, one with correct length and one with incorrect length. CDI-incorrect length ring bouy rope put away.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed greater than 4 inch openings on fence.
#22 · Premises: emergency telephone provided −6
Phone number and address of location shall be listed at emergency phone. Observed no info posted at emergency phone. CDI-info posted.
Permits at this address
Other businesses at this address
- A99Hampton Inn Lake NormanLodging · Aug 2013 – Jul 2026 · 13 inspections
- A98.5Hampton Inn Lake NormanRestaurant · Aug 2013 – Jun 2026 · 22 inspections
Matched by street address. Each permit has its own grade and history.