‹ Back to search

6demerits

HARBORWATCH CONDOMINIUMS

200 NORTHWEST DRIVE, Davidson, NC 28036
Seasonal Swimming Pool · NC permit/State ID 2060500247
Latest result6 demerits
Last inspectedApr 22, 2026
Inspections on record15
On record sinceApr 23, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Apr 23, 2014: 4Apr 23, 2015: 10Apr 25, 2016: 6Apr 13, 2017: 22Apr 18, 2018: 16Apr 24, 2019: 4Apr 30, 2020: 18May 27, 2021: 4Jul 12, 2022: 0Apr 20, 2023: 10Apr 22, 2024: 4Apr 29, 2024: 8Apr 3, 2025: 16May 1, 2025: 0Apr 22, 2026: 6
Apr 23, 2014Lower is betterApr 22, 2026

Inspections & violations

Apr 22, 2026 6 demerits · 2 violations
Inspector comments: NO NIGHT SWIMMING. Permit Restriction: Flow meter must remain operable. Flow shall not exceed 119 gpm due to drain cover flow restriction. Suction Hazard
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed wall and pool furniture < 6’ from pool edge. CDI
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed discharge pipe inside drain.

View this inspection on the county portal ›

May 1, 2025 0 demerits · 0 violations
Inspector comments: No night swimming. Permit restriction - flow meter must remain operable. Flow shall not exceed 119gpm due to drain cover flow restriction.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 3, 2025 16 demerits · 3 violations
Inspector comments: No night swimming. Permit denied. Phone sign is partially covered by maple tree. Phone is completely covered with a small walk way. Ensure phone is accessible at all times. Phone signage is in compliance as at sign stating the phone location is within the immediate pool area. Chemical feeder has been changed to an erosion feeder.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope exceeding 36’. CDI: Rope cut to length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed opening of fence to be 10.5”x11.5” and another section that is 8.5” x 16” near white fenced in raised deck. Observed foothold in same area at 24”. Close gap with approved material that is permanently affixed.

View this inspection on the county portal ›

Apr 29, 2024 8 demerits · 2 violations
Inspector comments: NOTE: - PIC: Matt Yates present during operational permit inspection. PERMIT RESTRICTION: Flow meter remain operator. Flow shall not exceed 119 GPM due to drain Cover Flow restriction.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
REPEAT .2537(b) All gates and doors shall be self-closing, self-latching.- Observed one gate that lead into residential space are not self-closed or self latched. One gate at the back entrance needs to be easily self latching/ latching at half way. Items fixed at the time of re-inspection. Ensure all gates are self-closing/latching at all time (full or half way).
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
REPEAT .2522(b) Provide at least 5 ft of clear walking space around the pool at all times.- Observed 3 ft from furniture and the edge of the pool. Rearranged the furniture to provide 5ft at the time of re-inspection.

View this inspection on the county portal ›

Apr 22, 2024 4 demerits · 1 violation
Inspector comments: NOTE: - Advise to trim down the shrubs where the pool phone located to provide easy access and visibility where the phone located. - PIC: Mr. Brian Pridmore present during inspection permit. - This pool # 500247, permit denied today due to gates are not self-closed/lacthed. - All items needs to be repaired/replaced, and ensure it is in good working condition. - Contact EHS: 704-617-9777 or email for return inspection to obtain the operational permit. - The pool shall remain closed until permit is issued. - Return visit fee is $100. Need to be paid through the office: 980-314-1620 prior to inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching.- Observed two gates that lead into residential space are not self-closed or self latched. The two at the front entrance and back need to be easily self latching at half way. Items need to be repair.

View this inspection on the county portal ›

Apr 20, 2023 10 demerits · 3 violations
Inspector comments: NO NIGHT SWIMMING
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed floating debris in skimmers. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed openings in pool enclosure > 4”.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Insufficient lighting in pump/chemical room.

View this inspection on the county portal ›

Jul 12, 2022 0 demerits · 0 violations
Inspector comments: EHS confirmed that all non complaint items from previous inspection (4x4 openings in gates) have been fixed. EHS confirmed PDSC information during inspection. Operator Kara Gilchrist on site during inspection. Permit issued.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 27, 2021 4 demerits · 1 violation
Inspector comments: Kara Gilchrist present during the inspection. Verified main drains, equalizers and pumps. Seasonal permit issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed All tenant gates swing towards the pool.

View this inspection on the county portal ›

Apr 30, 2020 18 demerits · 3 violations
Inspector comments: No signature required due to COVID-19.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. pH was 8.4. Pool operator got pH down to 7.5
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope length is 36ft and the rope measured 37ft. Pool operator cut a foot off of rope.
#22 · Premises: emergency telephone provided −6
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Emergency phone is located on the left side of the front gate behind the bush. The location of the emergency phone is on the pool rules sign but it was blank, not providing information. The pool operator filled out the blank.

View this inspection on the county portal ›

Apr 24, 2019 4 demerits · 2 violations
Inspector comments: CPO Kara Gilchrist was present during the inspection. Night Swimming is not permitted.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. - Observed water standing in the pump room. EHS did not observe any leaking pipes or equipment.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
(.2512) - Provide back flow prevention. - Observed no back flow prevention device on the hose bib located near the pool deck.

View this inspection on the county portal ›

Apr 18, 2018 16 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in the surface skimmer. Cleaned out the skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrails and recess ladder. Corrected during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction. Chair and lounge chair within 6 feet of the pool. Corrected during inspection. PIC relocated chair and lounge chair.
#22 · Premises: emergency telephone provided −6
Incorrect phone number for the facility. Corrected during the inspection. Wrote proper phone number on the emergency telephone poster. Correct phone number 704.894.9983

View this inspection on the county portal ›

Apr 13, 2017 22 demerits · 5 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed vacuum fitting not self closing or self latching. CDI-CPO provided secured cap.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy throw rope greater than required 36'. CDI-shortened to 36'.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed openings in fence and gate >4"
#22 · Premises: emergency telephone provided −6
Observed no sign indicating location of emergency phone. CDI-location written on pool rules sign.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet.

View this inspection on the county portal ›

Apr 25, 2016 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Keep furniture >6' from pool edge
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on the pump room floor

View this inspection on the county portal ›

Apr 23, 2015 10 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed openings in fence and gates > 4".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed handrail < 5' from brick wall.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on the floor in pump room.

View this inspection on the county portal ›

Apr 23, 2014 4 demerits · 1 violation
Inspector comments: 22. Clear/cut back tree so access to emergency phone is wider.25. Pump/equipment room has a 6-'7' ceiling.28. No shower is present or restrooms. Condos each have their own facilities. 3 buildings share the pool.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gates/fences have openings >4" and gates have cross bars <45" that create foot holds.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HARBORWATCH CONDOMINIUMS” or State ID 2060500247). Inspection type (routine vs. follow-up) is not published in the county's data.