10demerits
HIGHLAND CREEK-PROSPERITY
5710 FAIRVISTA DR, Charlotte, NC 28269
Seasonal Swimming Pool · NC permit/State ID 2060500263
Latest result10 demerits
Last inspectedApr 28, 2026
Inspections on record13
On record sinceMay 1, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 1, 2014Lower is betterApr 28, 2026
Inspections & violations
Apr 28, 2026 10 demerits · 3 violations
Inspector comments: PERMIT RESTRICITON: Flow required at least 335gpm to meet turnover. Flow meter must remain operable.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers in need of cleaning.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed no labels or flow arrows on piping. CDI- CPO wrote labels/ arrows.
Apr 28, 2025 10 demerits · 2 violations
Inspector comments: EHS observed flow at 349 gpm today. Pool not approved for night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope greater than the required 50 ft. CDI PO cut rope and adjusted it to 50 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
Observed openings under fence > 4”. CDI PO put rocks under fence.
May 17, 2024 14 demerits · 4 violations
Inspector comments: NO NIGHT SWIMMING.
Field verified:
New Pump Jandy JCP Serie, JCP05-3AT-S, 5 hp pump
Flow meter must be operable. Confirm the measurements provided measures at least 20 on the pipe before the flow meter and at least 8” on pipe after the flow meter back to the returns. Flow should read greater than 335 gpm.
Piping Main drain line is a 6” line; Skimmer and return are 4” these are measured with pipe coming out of the pump room floor.
(2) Aquastar VGBA-2017 1216xxx drain covers
(11) skimmers with EQ lines plugged
(4) Pentair TR140C filters
(20) returns either on wall or floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs.
Observed 2 missing weirs. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
Observed openings under fence > 4”.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(f) Provide a vacuum cap or self-closing cap.
No vacuum cap on vacuum line. CDI
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels.
Need directional flow markings on piping.
Apr 19, 2023 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor .
Apr 14, 2022 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight debris on pool floor
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed none
Apr 15, 2021 4 demerits · 2 violations
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap for filter backwash.
**.2513(b) Filter backwash shall be discharged through an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof.
**.2526(k) Provide shatterproof mirrors.
May 7, 2020 14 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
weir missing, corrected during inspection
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
vacuum plug missing, corrected during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
mirrors to be of shatter-proof construction
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
floors should be slip-resistant
May 1, 2019 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering.
.2530(c) Provide "Adults should not swim alone." in 1" lettering.
Required approved wording on signage not present. Approved signage provided and affixed while on site.
Apr 24, 2018 4 demerits · 1 violation
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
Observed windows in club house open over 12". CDI alarms placed on windows.
May 4, 2017 2 demerits · 1 violation
Inspector comments: Pool has passed pre-inspection. Post pool permit in public view from the pool deck when permit is issued.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed backwash line not to have an air gap.
Jul 18, 2016 24 demerits · 7 violations
Inspector comments: Intent to suspend issued.
25)
#3 · Water quality: pool water pH −6
pH 6.9. Maintain between 7.2 and 7.8. Corrected to 7.2.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two weirs stuck. Provide functional weirs.
Two of the far skimmers not pulling. Maintain functional skimmers.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some deck chairs too close to pool edge. Maintain at least 8 feet clear walkway around the pool. Corrected by operator.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Repair or replace.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical storage room used for general storage. Use chemical storage ONLY for storing pool chemicals.
Large container of liquid chlorine stored within a few inches of pool pump. Store Chemicals in chemical storage room. Maintain at least 3 feet clear walkway around pool equipment. - Intent to suspend item.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap for backwash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Loose faucet in mens restroom. Maintain fixtures secure and in good repair.
Apr 22, 2015 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed the pool floor with leaves and debris. **Keep the pool floor clean at all times.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed the vacuum port adapter was still attached. The adapter was removed and the port was covered during the inspection. **Keep the vacuum port covered at all times.General Comments: Scott Ready was present during the inspection.The pool permit will be available for printing in 3 business days at meckpools.charmeck.org
May 1, 2014 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Maintain the pool floor free of debris. Observed leaves and other debris in the pool. Cleaned onsite.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Maintain skimmers clean. Observed leaves and debris. Cleaned onsite.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HIGHLAND CREEK-PROSPERITY” or State ID 2060500263). Inspection type (routine vs. follow-up) is not published in the county's data.