‹ Back to search

0demerits

HOBBS RIDGE

3724 SELWYN FARMS LN, Charlotte, NC 28209
Seasonal Swimming Pool · NC permit/State ID 2060500267
Latest result0 demerits
Last inspectedMay 14, 2026
Inspections on record13
On record sinceApr 23, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0612 Apr 23, 2014: 8Apr 23, 2015: 8Apr 15, 2016: 12Apr 26, 2017: 12Apr 16, 2018: 10May 1, 2019: 2May 28, 2020: 0Apr 28, 2021: 8Apr 20, 2022: 2Apr 13, 2023: 6Apr 26, 2024: 0Apr 23, 2025: 10May 14, 2026: 0
Apr 23, 2014Lower is betterMay 14, 2026

Inspections & violations

May 14, 2026 0 demerits · 0 violations
Inspector comments: Pool is open for the 2026 season. No night swimming. New covers installed PDSC form was approved. Permit restrictions: Flow meter must remain operable. Flow required at 89 gpm to 100 gpm to meet turnover and flow restriction of the filter. Flow greater than 170 gpm is suction hazard.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 23, 2025 10 demerits · 3 violations
Inspector comments: Inspection with CPO, Pierce Sawyer No night swimming Permit Restriction: Flow meter must remain operable. Flow required at 89 GPM to 100 GPM to meet turnover and flow restriction of the filter. Observed flow at 90 GPM. EHS verified: Operable blue white flow meter installed in 2” line Main drain, skimmer, and return line all with 2” pipe (2) Aquastar A10RCFRxxx 2008 main drain covers (3) Aquastar A10RCFRxxx 2008 EQ line covers Pentair TR100 filter rated for 100 GPM 6 returns installed on pool wall
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed minor pollen/dirt residue in the middle of the pool floor.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed bend in fence that was 6”. CDI-CPO corrected bend in fence to be 4”.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed backwash pipe without an air gap.

View this inspection on the county portal ›

Apr 26, 2024 0 demerits · 0 violations
Inspector comments: Inspection conducted with CPO Pierce Sawyer. No violations observed.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 13, 2023 6 demerits · 1 violation
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed 0PPM CL at the beginning of inspection. PO discovered the filter had been clogged. PO unclogged and pool reached 1 PPM CL by the end of inspection

View this inspection on the county portal ›

Apr 20, 2022 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
no air gap in backwash.

View this inspection on the county portal ›

Apr 28, 2021 8 demerits · 2 violations
Inspector comments: EHS recommends adding a back flow preventer to the on deck hose Bibb. Per CPO Facility does not use this hose to add water to the pool, only to clean restrooms. No night swimming.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy severely damaged. CDI: New ring buoy provided.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap for backwash.

View this inspection on the county portal ›

May 28, 2020 0 demerits · 0 violations
Inspector comments: Observed crack on pool deck near hand rail. Observed depth and no diving markers on deck beginning to fade. Verified PDSC information. Pump Verified in field Sta Rite Duraglass p2ra5fl Pierce Sawyer present during inspection. No signature due to COVID19 Social Distancing Requirements.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 1, 2019 2 demerits · 1 violation
Inspector comments: PDSC form verified (pump 'in field' approved).
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap available.

View this inspection on the county portal ›

Apr 16, 2018 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris floating in pool.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed surface of deck damaged in several area.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed inadequate air gap at backwash line

View this inspection on the county portal ›

Apr 26, 2017 12 demerits · 4 violations
Inspector comments: General Comment: Due to insufficient lighting pool is prohibited from night swimming. Pool closes at 8pm (dusk).
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris inside skimmers. Cleaned during inspection.
#18 · Premises: lifeguards present or warning signs posted −4
Observed "No lifeguard on duty" warning sign posted. Correct sign posted during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
Provide air gap at backwash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed trash bag and chairs stored inside one of the restrooms - Remove.

View this inspection on the county portal ›

Apr 15, 2016 12 demerits · 4 violations
#22 · Premises: emergency telephone provided −6
Emergency phone located in area not visible to entire pool deck with no sign directing location of phone. CDI- PIC placed location on rules sign so that both sides of pool deck can see.
#27 · Equipment room: filter backwash discharged through an air gap −2
Air gap needed in backwash station.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Cleaning needed in both restrooms. Remove all storage from restrooms.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed fill spout protrude over 5 inches in to the pool. Fill spouts shall not protrude more than 2 inches into pool.Backflow prevention device required

View this inspection on the county portal ›

Apr 23, 2015 8 demerits · 3 violations
#18 · Premises: lifeguards present or warning signs posted −4
Observed no lifeguard on duty sign posted. Observed no shower before entering sign posted. CDI signs posted.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed an inadequate air gap on the backwash line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no papertowel in the restrooms. Observed non-shatter proof mirrors in the restrooms.

View this inspection on the county portal ›

Apr 23, 2014 8 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool floor dirty. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder near 5' depth is loose.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
No backflow preventer on hosebib.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “HOBBS RIDGE” or State ID 2060500267). Inspection type (routine vs. follow-up) is not published in the county's data.