‹ Back to search

4demerits

6300 WOODBEND LLC

6320 WOODBEND DR, Charlotte, NC 28212
Seasonal Swimming Pool · NC permit/State ID 2060500287
Latest result4 demerits
Last inspectedMay 19, 2026
Inspections on record11
On record sinceJun 17, 2015

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01734 Jun 17, 2015: 34Jun 9, 2016: 20Jun 14, 2016: 6Jun 7, 2017: 4May 21, 2018: 12May 24, 2019: 4Jun 1, 2021: 6May 11, 2023: 16May 15, 2024: 12Apr 30, 2025: 20May 19, 2026: 4
Jun 17, 2015Lower is betterMay 19, 2026

Inspections & violations

May 19, 2026 4 demerits · 1 violation
Inspector comments: Inspection conducted with Juan Compres. No night swimming. No violations noted. PERMIT RESTRICTION: Flow meter required operable. Flow required at 74 gpm due to filter flow restriction. Turnover not met at 112 gpm. Filter may require change if clarity issues occur. ITEMS VERIFIED DURING INSPECTION New Pump Pentair IntellifloVS + SVRS 011057, 3 hp pump Blue White flow meter reading within the range above. 2” main drain and skimmer line; 3” return line (coming out of the pump room floor). (2) Aquastar 2008 A10RCFRxxx drain covers. (4) skimmers with EQ lines disabled in skimmer and on wall. (1) Pentair TR100 filter (8) returns either on the wall or the floor.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Distance between fence horizontals measured at <30”. Pool constructed prior to 2010.

View this inspection on the county portal ›

Apr 30, 2025 20 demerits · 4 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed weirs improperly installed. CPO installed weirs correctly.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding 42ft. CPO cut rope to required length during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Observed gates and fencing with approximately 26 inches between horizontals. CPO attached plexi-glass on gates. Pool was constructed pre May 2010. .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate closest to lifeguard sign not self-closing, self-latching. CPO repaired magna latch during inspection. EHS observed gate self-closing self latching.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone connect to 911, but was unable to be called back at beginning of inspection. CPO repaired emergency phone box. EHS was able to call emergency phone box and connect to it at end of inspection.

View this inspection on the county portal ›

May 15, 2024 12 demerits · 3 violations
Inspector comments: Juan Compres present during inspection. Night swimming not permitted. Contrasting band on steps has 4-5 tiles fading. Replace or paint fading tiles by 2025. Permit will not be issued in 2025 if not addressed, No Diving stenciled lettering on pool deck fading. Repaint before 2025 pool season. 2025 permit will not be issued until addressed.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Initial pH check showed 7.0 pH. Operator Juan Compres raised pH while on site to 7.2.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weirs in 4 skimmers. CDI: Weirs provided.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Ladders and hand rail loose. Operator tightened while on site.

View this inspection on the county portal ›

May 11, 2023 16 demerits · 4 violations
Inspector comments: No night swimming. Permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weirs in 2 skimmers. CDI: Weirs provided.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed bumper caps on ladders missing.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy was 30’. Required length of 42’ needed. CDI: Rope provided.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed access gate at shallow end of pool not self closing, self latching. CDI: Gate made to self close, self latch during inspection.

View this inspection on the county portal ›

Jun 1, 2021 6 demerits · 2 violations
Inspector comments: Inspection conducted alongside CPO Juan.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2543 The surge container for interactive play attractions shall be kept accessible and shall maintain an operable surface skimmer. Debris observed in skimmer baskets. Remove debris.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. No proof of shatterproof mirrors.

View this inspection on the county portal ›

May 24, 2019 4 demerits · 1 violation
Inspector comments: Observed footholds along the outside of fence today that are electrical connectors, but at each foothold, there is a light post inside the fence blocking the area.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basket today. CDI - Operator sent technician to purchase during inspection. -4-

View this inspection on the county portal ›

May 21, 2018 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One weir was missing. CDI Weir replaced
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
2 No Diving markers were missing at each end of the pool. CDI Both painted onto deck during inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Both lights were loose. CDI both were tightened.

View this inspection on the county portal ›

Jun 7, 2017 4 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 - Ladders and handrails must be installed where required and maintianed in good repair. Tighten loose ladder on back side of pool.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513 - Provide a backwash with appropriate air gap to prevent backflow. Backwash discharge pipe extends below flood rim of floor drain. Shorten pipe so that it ends above the floor drain.

View this inspection on the county portal ›

Jun 14, 2016 6 demerits · 2 violations
Inspector comments: Water clear enough to see main drain. Cl @ 8.0 Ladder tightened.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool light loose.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose bibb need back flow preventer.

View this inspection on the county portal ›

Jun 9, 2016 20 demerits · 5 violations
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Could not see main drain due to cloudy water. water should be clear enough to see main drain at all times.
#2 · Water quality: disinfectant residual provided by −6
Cl was 0.8 CDI to 1.5
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
ladder is very loose. Tighten ladder.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
Pool light has come loose from wall. Reattach light.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose bibb did not have a back flow preventer.

View this inspection on the county portal ›

Jun 17, 2015 34 demerits · 9 violations
#2 · Water quality: disinfectant residual provided by −6
Observed cl2 to be at 0.5ppm. Feeder was adjusted and cl2 came up to 1.0ppm. -C.D.L.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed TA and CA recorded as pass/fail. They must be recorded as a number of parts per million.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmers missing weirs. Weirs were installed. -C.D.I.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder to be loose. Repair it.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed non-Coast Guard approved ring buoy in use. Ring buoy must be Coast Guard approved. -I.S. Issued. Ensure throw rope is exactly 42ft. long.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed areas of deck to be cracked and damaged. Repair it.
#18 · Premises: lifeguards present or warning signs posted −4
Observed incorrect signs posted. Correct signs were found and posted. -C.D.I.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no backwash line air gap.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no backflow preventer on hose bibb.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “6300 WOODBEND LLC” or State ID 2060500287). Inspection type (routine vs. follow-up) is not published in the county's data.