‹ Back to search

6demerits

BAYSHORE CONDOMINIUMS

17917 KINGS POINT DRIVE, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060500310
Latest result6 demerits
Last inspectedApr 14, 2026
Inspections on record13
On record sinceMay 15, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 May 15, 2014: 6Apr 7, 2015: 10Apr 19, 2016: 6May 16, 2017: 4Apr 2, 2018: 2Apr 11, 2019: 18Apr 21, 2020: 8Apr 6, 2021: 4Apr 21, 2022: 8Apr 14, 2023: 10Apr 24, 2024: 0Apr 28, 2025: 0Apr 14, 2026: 6
May 15, 2014Lower is betterApr 14, 2026

Inspections & violations

Apr 14, 2026 6 demerits · 1 violation
Inspector comments: No night swimming
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Ring buoy was not located at pool at start of inspection and was stored in the pump room. Moved to pool deck during inspection.

View this inspection on the county portal ›

Apr 28, 2025 0 demerits · 0 violations
Inspector comments: No violations observed during inspection. No night swimming. No permit restrictions.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 24, 2024 0 demerits · 0 violations
Inspector comments: No violations noted during inspection

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 14, 2023 10 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope damaged. Replaced ring buoy
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
2 gates open towards pool. Slope of yard does not allow for gates to open away from pool

View this inspection on the county portal ›

Apr 21, 2022 8 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool has small amount of debris in bottom corrected during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
2 Gates open towards pool. Topo does not allow for gates to open correct direction. Pool built in 1991. Gap greater than 4" near condo section of fence. Corrected during inspection

View this inspection on the county portal ›

Apr 6, 2021 4 demerits · 2 violations
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed no forced or cross ventilation in the pump room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(h) Shower(s) shall be provided. Observed shower not working. CDI - Operator turned on water to shower.

View this inspection on the county portal ›

Apr 21, 2020 8 demerits · 3 violations
Inspector comments: NO NIGHT SWIMMING ALLOWED. DUE TO COVID-19 RESTRICTIONS, PERMIT WILL NOT BE SIGNED BY OPERATOR.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. ladders extend > 6" from pool wall.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). observed openings under fence > 4" .2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. 2 gates swing into pool enclosure due to topography at outside of gate.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. provide air gap at backwash pipe outlet

View this inspection on the county portal ›

Apr 11, 2019 18 demerits · 6 violations
Inspector comments: Safety equipment should be relocated where it is accessible in the case of an emergency There are no restroom facilities at this pool
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders should not extend > 6" from pool edge
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gap under fence > 4"
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light bulb needs to be replaced
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Valves and pipes remarked during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on back flow preventer
#22 · Premises: emergency telephone provided −6
Phone number corrected during inspection

View this inspection on the county portal ›

Apr 2, 2018 2 demerits · 1 violation
Inspector comments: 17) Observed deck chipping in 5 foot end, that is less than .5" hazard. Repair deck area.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Observed no functioning light in pump room.

View this inspection on the county portal ›

May 16, 2017 4 demerits · 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck cracking in various places.

View this inspection on the county portal ›

Apr 19, 2016 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Address the cracks on the deck and re-surface the decking
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label pipes in the pump room

View this inspection on the county portal ›

Apr 7, 2015 10 demerits · 3 violations
Inspector comments: NOTE: Permit will be posted online within 3 days at meckpools.charmeck.org.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Replace some pool tiles on pool wall. Observed lots of debris in pool.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain 6ft deck clearance. Observed some chairs < 6ft. Moved back during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed some wall damage in pump room. Repair.

View this inspection on the county portal ›

May 15, 2014 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Main gate closes properly. The other four gates are to be kept locked unless they are self closing.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor is wet and walls are water damaged.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BAYSHORE CONDOMINIUMS” or State ID 2060500310). Inspection type (routine vs. follow-up) is not published in the county's data.