4demerits
BISCAYNE CONDOMINIUMS
17933 KINGS POINT DRIVE, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060500312
Latest result4 demerits
Last inspectedApr 17, 2026
Inspections on record13
On record sinceApr 22, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 22, 2014Lower is betterApr 17, 2026
Inspections & violations
Apr 17, 2026 4 demerits · 1 violation
Inspector comments: No Night Swimming
Verified new PDSC information approved on 4/17/26
Gates leading onto pool deck from private residences self close, latch, and meet 48” height.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Slight debris on floor of pool, cleaning in progress during inspection.
Apr 28, 2025 6 demerits · 1 violation
Inspector comments: No night swimming.
No permit restrictions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed rope for ring buoy at 40’ long. CDI: CPO cut rope to 39’.
Apr 24, 2024 0 demerits · 0 violations
Inspector comments: No violations noted during inspection
No violations were recorded for this inspection.
Apr 25, 2023 2 demerits · 1 violation
#26 · Equipment room: valves and pipes identified by color codes or labels −2
relabel pipes in pump room
Apr 14, 2022 12 demerits · 3 violations
Inspector comments: Night swimming not permitted.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool pH 7.0 at beginning of inspection. CDI - Operator corrected to 7.2 during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed furniture less than 6 feet from pool edge. Operator relocated.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Light not operating in pump room.
Apr 26, 2021 4 demerits · 2 violations
Inspector comments: Michael Morgan present for inspection.
No night swimming.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed missing end caps on one of two ladders.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed no cross ventilation in pump/chemical room. Door had two vents, one above the other, and fan was inoperable.
Apr 24, 2020 14 demerits · 4 violations
Inspector comments: NIGHT SWIMMING PROHIBITED.
DUE TO COVID-19 RESTRICTIONS PERMIT WILL NOT BE SIGNED BY OPERATOR.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.
observed pH 7.0. CDI corrected to 7.2.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
observed end caps missing on ladder.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
observed sections of enclosure wall < 48".
.2528(a) Provide no openings in fence and/or gate greater than 4"x4".
observed openings in deck vertical slats > 4"
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
no cross ventilation in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
pump room floor wet
May 3, 2019 12 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy rope 2' too short. Corrected during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate latch broken. Corrected during inspection. Fence is not 48 inches along building side of pool Const Date 1992.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash
May 8, 2018 8 demerits · 3 violations
Inspector comments: NO POINTS WERE TEKEN FOR THE FOLLOWING:
#24 - .2518(e) Provide a spare basket for pump. Observed no extra pump basket onsite. CDI: Operator provided basket from truck.
PDSC Information verified. No night swimming.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one pool ladder without protective bumpers. Provided bumpers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed pool fencing to be less than 48 inches in several areas.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. REPEAT Observed pump room floor to be wet with debris. Keep pump room floor dry and clean.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed hose bib on shower without back flow prevention.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed ventilation fan not working in pump room.
Apr 20, 2017 22 demerits · 5 violations
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0ppm. CPO stated valve on chlorine feeder was stuck. CPO adjusted valve and chlorine measured 6.0 on one side of pool and 1.0 at other end of pool.
#3 · Water quality: pool water pH −6
Observed pH at 8.4. pH was adjusted and reading 7.2.
#18 · Premises: lifeguards present or warning signs posted −4
"NO LIFEGUARD ON DUTY" sign not posted. CDI-posted.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
SIgn prohibiting glass containers and pets not posted. CDI-posted.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet.
Jun 1, 2016 0 demerits · 0 violations
Inspector comments: Pool looks awesome
No violations were recorded for this inspection.
Apr 13, 2015 22 demerits · 7 violations
Inspector comments: NOTE.: Permit will be posted online within 3 days at meckpools.charmeck.org
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed some missing tiles on pool wall.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
•Observed lots of debris in skimmers.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Maintain "FT" and "no diving" signs easily readable. Observed "FT" and one "No diving" sign faded. Corrected temporarily with black permanent marker during inspection until stencil can be provided.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Replace one missing end cap on ladder.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain 6ft deck clearance around pool. Observed lawn chairs < 6ft. Chairs moved back during inspection. Repair one side of deck closest to entrance where concrete is cracking.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed sheet rock in pump room peeling and floor damage.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Provide backflow prevention on deck hose bib below shower.
Apr 22, 2014 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Keep chemicals off the floor and some damage noted to pump room walls.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “BISCAYNE CONDOMINIUMS” or State ID 2060500312). Inspection type (routine vs. follow-up) is not published in the county's data.