‹ Back to search

14demerits

WENDOVER GARDENS

2347 EASTWAY DRIVE, Charlotte, NC 28205
Seasonal Swimming Pool · NC permit/State ID 2060500341
Latest result14 demerits
Last inspectedMay 6, 2026
Inspections on record11
On record sinceJul 8, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02244 Jul 8, 2013: 24May 21, 2014: 10Jun 15, 2015: 0Jun 20, 2016: 20Jun 16, 2017: 16Jun 10, 2022: 10May 4, 2023: 14Jul 23, 2024: 10Jul 21, 2025: 6Sep 12, 2025: 44May 6, 2026: 14
Jul 8, 2013Lower is betterMay 6, 2026

Inspections & violations

May 6, 2026 14 demerits · 4 violations
Inspector comments: PERMIT RESTRICTION: FLOW METER MUST REMAIN OPERABLE. TURNOVER CANOOT BE MET DUE TO FLOW RESTRICTION OF THE FILTER. FLOW SHALL BE KEPT AS CLOSE TO 98 GPM AS POSSIBLE. FLOW GREATER THAN 170 GPM EXCEEDS MAIN DRAINS. SUCTION HAZARD. NO NIGHT SWIMMING.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no column for main drains checked daily. Include a column for checking main drains in daily logs.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed one skimmer basket full of debris. CDI CPO dumped out skimmer basket.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed one missing endcap on ladder. Replace missing endcap.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed damaged stainless steel cup around ladder railing. Repair damaged cup to prevent possible hazards.

View this inspection on the county portal ›

Sep 12, 2025 44 demerits · 11 violations
Inspector comments: OSV to pool for permit inspection and in-field plan review with pump change. Verified the following during the inspection. 1) Permit Restriction: Flow meter must remain operable. Turnover cannot be met due to flow restriction of the filter. Flow shall be kept as close to 98 gpm as possible. Flow greater than 170 gpm exceeds main drains. Suction Hazard. 2) New Pump - Hayward Tristar VS 950, SP32950VSP meeting above permit restriction on Blue white flow meter. 3) Main drain and skimmer - actual 2.5"; return line - 2". 4) (2) Aquastar 2017 914xxx drain covers. 5) (3) skimmers with no EQ line covers. 6) Pentair TR100C filter rated for 98 gpm. 7) (8) wall returns. Pump approved. See inspection for items listed as Permit Denial items for items to correct prior to scheduling a return inspection.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Operator not completing daily main drain checks. Record daily main drain checks to ensure drains are secure on the pool floor. Permit Denial.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Equalizer lines not plugged per State requirement inside the skimmer. Disabled on wall. Plug per State requirement. Permit denial. Main drains not flush to pool floor. Provides lip. Permit denial. PDSC form with incorrect number of skimmers listed. Pool has 3 skimmers. Update PDSC form to reflect accurate number. Permit denial.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
(1) of 3 skimmers missing weirs. Replace weir.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Grab rope on ring buoy degrading and rope too short. Provide new USCG approved ring buoy with 45 ft. rope. Permit denial.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Doors from main office with audible alarm. Doors shall self-close, with audible alarm or self-close, self-latch. Given to 2026 operating season to add self-closers.
#22 · Premises: emergency telephone provided −6
No dialing instructions at pool phone. Signage moved to reflect dial 911 during the inspection.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Chlorine pucks in the skimmer baskets. Direct hazard to the public. Could not verify that the chlorinator was operable. Swimming pool shall be chlorinated through the feeder. No chlorine pucks in the skimmer baskets. Permit denial. Flow meter for chlorinator filled with chlorine and not operable. Flow meter shall be kept operable for NSF approval.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
No spare pump basket for new pump. Provide spare pump basket. Permit denial.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Backwash pit pipe runs across pump room floor. Provide 3 ft. clearance around equipment.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No hose bib in restrooms. Original construction. Provide hose bib in restrooms.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose bib in pump room without backflow prevention. Provide backflow prevention device on hose bib.

View this inspection on the county portal ›

Jul 21, 2025 6 demerits · 1 violation
Inspector comments: Facility will need to call and request reinspection after repairs are made
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed one main drain cover, not fitting flush to the bottom of the pool. EHS was able to take the end of the Shepherd’s crook and wedge it underneath the opening which appears to be 3/8 to 1/2 an inch above the surface of the pool. This represents not only an entrapment hazard, but a change in the pattern of the flow that has not been tested.

View this inspection on the county portal ›

Jul 23, 2024 10 demerits · 3 violations
Inspector comments: ENSURE GRANULAR DEBRIS ON POOL FLOOR IS NOT SAND COMING FROM DAMAGED INTERNAL FILTER LATERAL.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed granular debris on floor of pool.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times.observed multiple chez lounge chairs within 6 ft of pool edge while pool closed to patrons. CDI relocated further away
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed insufficient.

View this inspection on the county portal ›

May 4, 2023 14 demerits · 4 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed expired test kit in the facility during inspection.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed depth markers wiping off from pool deck. Needs to be remarked.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed openings by the fence greater than 4 inches.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water leaks in equipment room.

View this inspection on the county portal ›

Jun 10, 2022 10 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Daily log sheet does not have column for drain checks. CDI- sent Daily Log sheet that contains drain checks.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Phone # and address not posted. CDI- posted by end of inspection. Phone automatically dials 911. Spoke with 911 operator, called back phone number and phone rang.

View this inspection on the county portal ›

Jun 16, 2017 16 demerits · 3 violations
Inspector comments: l7. Observed slightly chipped plaster on the steps to the pool. Repair in off season.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed pool missing 2/3 weirs at time of inspection. Intent to suspend issued. Facility has 30 days to replace weirs or permit will be suspended.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope buoy was observed in disrepair. Replaced by operator during inspection.
#22 · Premises: emergency telephone provided −6
Phone was observed to be properly functioning but no sign indicating the phone number or address to the pool was present. Provided by operator during inspection.

View this inspection on the county portal ›

Jun 20, 2016 20 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool walls peeling. Debris in pool.
#13 · Pool maintenance: contrasting band on steps and benches −4
Observed contrasting band on steps fading significantly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Only swinging gate into pool swings toward pool. Correct within 30 daysto avoid permit suspension.
#22 · Premises: emergency telephone provided −6
Observed phone number posted is not same as reported by 911 operator. Corrected while on site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Damaged sheetrock from moisture in chemical room.

View this inspection on the county portal ›

Jun 15, 2015 0 demerits · 0 violations
Inspector comments: OSV to lift immediate suspension for water quality. Water clear to view main drain screws. Circulation strong, skimmer boxes clean, weirs in tact. Handrail at stairs repaired. New multiport, sand, and piping installed. Flow meter working. Deck repaired. Fence repaired to prevent entry. Bathroom repaired. Immediate suspension lifted. Pool place on "A" status.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 21, 2014 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Keep pool walls and floors clean; Observed pool flooring collecting debris in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Keep skimmer systems clean and in good repair; Observed skimmer baskets broken in need of replacing; Observed skimmer baskets in need of cleaning.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Keep restrooms in good repair; Observed lights not functioning in restrooms.

View this inspection on the county portal ›

Jul 8, 2013 24 demerits · 6 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool floor w/debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer baskets w/debris.GC: skimmers are no longer plugged.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing end caps on ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed ring buoy rope was 50ft. CDI-corrected to 45ft.
#22 · Premises: emergency telephone provided −6
Observed no address posted at emergency phone. CDI- address was added to sign.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no soap and paper towels available and fixtures were dirty.

View this inspection on the county portal ›