22demerits

MEADOWBROOK APARTMENTS

2320 GINGER LANE, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060500364
Latest result22 demerits
Last inspectedAug 4, 2026
Inspections on record10
On record sinceJun 30, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 Jun 30, 2014: 20May 28, 2015: 6Jul 12, 2016: 2Aug 1, 2018: 2Jul 3, 2019: 10Sep 12, 2024: 18Sep 20, 2024: 0Jun 5, 2025: 4Jun 8, 2026: 10Aug 4, 2026: 22
Jun 30, 2014Lower is betterAug 4, 2026

Inspections & violations

Aug 4, 2026 22 demerits · 7 violations
Inspector comments: Inspection conducted with CPO Juan Payamps and office staff Amy Villegas. Observed new ring buoy with 30 foot throw rope. Observed doors to office and restroom now alarmed. Some chips and cracks in deck and coping. Maintain in good condition with no gaps or offsets > 1/2 inches. Prior to 2027 permit being issued, will need to cap line for old fill spout at the deep end so it is no longer a trip hazard. Permit issued with the following conditions: No Night Swimming Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No log book. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. - Corrected. Left copy of state log sheet. CPO will start filling it out.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
In the process of refilling the pool. Water below the skimmers, skimmers off in the pump room. .2518(k) Water level shall be maintained to assure skimmers are operable. - Operator will turn the skimmers back on once the pool is refilled.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Both ladders missing endcaps. .2521 Install ladders per manufacturer instructions.
#18 · Premises: lifeguards present or warning signs posted −4
Safety signage missing. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Corrected. Temporary signage placed, facility ordering permanent signage. Safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected. Temporary signage placed, facility ordering permanent signage.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Spare pump basket not provided. .2518(e) Provide a spare basket for pump. - Corrected, ordered spare pump basket.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Restrooms locked on the weekends. Ensure restrooms are available whenever the pool is open. .2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments. - Corrected. Facility will leave restroom door unlocked whenever the pool is open.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bibb used to fill the pool does not have a backflow preventer. .2512 (b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap or vacuum breaker (ASSE 1020 or 1013).

View this inspection on the county portal ›

Jun 8, 2026 10 demerits · 2 violations
Inspector comments: Permit denial today
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 18FT instead of the required 30FT.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed 2 doors from the club house that lead directly to the pool not self-closing or having an audible alarm.

View this inspection on the county portal ›

Jun 5, 2025 4 demerits · 1 violation
Inspector comments: Pool flow meter measured 70 gpm. Permit restriction for pool is that flow must be 100 gpm to meet flow restriction of number of returns and turnover. CDI - Operator adjusted variable speed pump until the flow was 100 gpm. No night swimming permitted Drain covers and filtration pump verified via PDSC form during inspection Permit issued
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Drain cover inspections were not on daily log book. CDI - Operator added column for checking main drains.

View this inspection on the county portal ›

Sep 20, 2024 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED

No violations were recorded for this inspection.

View this inspection on the county portal ›

Sep 12, 2024 18 demerits · 5 violations
Inspector comments: *Items from Plan Review correct with the exception of 5 wall returns.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
ONE WEIR MISSING FROM SKIMMER IN SHALLOW END
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
ONE BUMPER MISSING FROM LADDER IN DEEP END.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
EYEBALL FITTING MISSING IN 3FT END -- REPLACE
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
GATE SWINGS TOWARD THE POOL
#18 · Premises: lifeguards present or warning signs posted −4
MISSING SIGNS: "WARNING - NO LIFEGUARD ON DUTY" MIN. 4" LETTERS "ADULTS SHOULD NOT SWIM ALONE" MIN 1" LETTERS "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" MIN 1" LETTERS

View this inspection on the county portal ›

Jul 3, 2019 10 demerits · 3 violations
Inspector comments: Night swimming has not been approved.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Observed missing weirs in both skimmers. Manager explained that they are on order and expected any day.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed loose ladders. Maintenance operator will purchase clamps to secure the ladder.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed no "warning no life guard on duty" sign. This was corrected and the maintenance operator had the sign ordered and put up a temporary sign with the correct wording and letter height until the sign can come in.

View this inspection on the county portal ›

Aug 1, 2018 2 demerits · 1 violation
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Hose bib does not have a backflow preventer.

View this inspection on the county portal ›

Jul 12, 2016 2 demerits · 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
15A ncac 18A.2521- Observed no end caps on hand rails. Operator has extra caps that need to be installed.

View this inspection on the county portal ›

May 28, 2015 6 demerits · 1 violation
#22 · Premises: emergency telephone provided −6
Phone number not posted on emergency phone. CDI Phone number of emergency phone posted by end of inspection.

View this inspection on the county portal ›

Jun 30, 2014 20 demerits · 4 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
One equalizer plugged. Keep equalizers unplugged. Corrected during insoection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Two ladders are loose.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Throw rope was 50'. Maintain at 30'. Corrected during inspection.
#22 · Premises: emergency telephone provided −6
Phone number not posted at Emergency Phone. Corrected during inspection.

View this inspection on the county portal ›