May 8, 2026 8 demerits · 2 violations
Inspector comments: Permit Restrictions:
Observed only deck lights, no pool lights. PIC stated that there is no night swimming.
Night Swimming is NOT permitted.
Flow required at 475 to 500 gpm to meet turnover and flow restriction of the designer. Flow meter must remain operable.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed some debris in skimmers. CDI PIC cleaned out all skimmers.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Observed benches and storage bin outside of the fence that were creating footholds less than 45 inches. Storage bin and benches were moved back to provided required clearance.
May 14, 2025 0 demerits · 0 violations
Inspector comments: No violations observed.
Permit Restriction:
Flow required at 500 GPM and flow meter must remain operable. Night swimming approved.
No violations were recorded for this inspection.
Apr 26, 2024 16 demerits · 3 violations
Inspector comments: Inspection completed with CPO, Brandon Vaughn
All permit compliance items corrected during inspection
Interlock tested and operating
CPO log records begin today
Drain covers expire 3/29/25, before next pool season.
Covers must be replaced and new PDSC form approved prior to inspection
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539 Pump is required to be set to 500gpm maximum. Observed pump set to 550 gallons per minute. CPO was able to turn it down and set it to exactly 500gpm.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. One buoy rope was cut from 54 feet to 50 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Observed benches and large pots outside of the fence that were creating footholds less than 45 inches. Pots and benches were moved back to provided required clearance.
May 17, 2023 12 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
two weirs missing
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
missing one bumper on ladder
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
both bathrooms need non-slip matts
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
two outlets missing eyeballs
Apr 28, 2022 2 demerits · 1 violation
Inspector comments: Ann Waters present during inspection. Observed flow rate at 500 GPM.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed soiled women’s restrooms and showers. Need Cleaning.
May 4, 2021 4 demerits · 1 violation
Inspector comments: EHS noticed labels on pipes in pump room are starting to fade. Re-label piping.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight leaf debris present in pool.
Jul 21, 2020 4 demerits · 1 violation
Inspector comments: Onsite visit with Anne, CPM
No signature due to COVID19 social distancing requirements.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed no attendant at gate, gate handle below 54 inches. Corrected during inspection.
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present.
May 27, 2020 2 demerits · 1 violation
Inspector comments: Onsite visit to pool for permit inspection and return construction final. Construction final passed with restriction. Check valve appears to be leaking with no catch drain. Install catch drain prior to return follow-up inspection by Chris Sells. Also, flooring in restroom could not be verified as slip-resistant. One section at entry to women's restroom does not seem slip-resistant. Provide technical/specification sheet for sealant on floor in restrooms. All other items corrected from construction final. Items listed above must be corrected by follow-up inspection or permit action will be taken.
Jeff Gaeckle and Vince Malta present during inspection. Emailed inspection report to contractors.
Permit issued for no night swiming. Issuance of a permit by this department does not negate closure required by Executive Order No. 141 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
Permit Restriction
1) Flow required at 500 gpm on flow meter. Flow meter must remain operable.
Ensure 8 ft. clearance behind diving board at all times.
Pool Width - >50 ft.
Rope Length - 50 ft.
Max Depth - 11 ft.
Filtration – Pentair EQK1500, 15 hp with (2) SUN18HP101 drain covers. EQ lines capped on underside.
Feature – Pentair EQ750, 7.5 hp with (2) SUN18HP1010 drain covers
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Backflow prevention device missing from hose bib at pump house. Replaced during inspection.
Apr 24, 2019 20 demerits · 5 violations
Inspector comments: Night time verification visit required. Pool has swim team night swimming. Pool is not permitted to night swim until visit is conducted.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed one rope > 50ft. CDI: cut to 50ft during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed openings at top of chain link fence by wading pool area > 4 inches. Pool built prior to 2010. CDI: corrected gaps in fencing during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed deck damaged at area close to lifeguard shack. CDI: repaired with vinyl concrete patcher during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not working. CDI: repaired and corrected during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(k) Provide shatterproof mirrors. Mirrors in restrooms not shatterproof.
Apr 13, 2018 18 demerits · 5 violations
Inspector comments: Marking on pipes in pump room starting to fade. Make sure to correct.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed missing cap on stairs far left end near feature.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed rope greater than 50 feet. CDI Operator trimmed to 50 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed on fencing (back entrance) greater than 4 inches across vertical.
*Pool built prior to 2010.*
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flowmeter clogged. CDI Operator unclogged flowmeter during the inspection.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed water in restroom far left greater than 110 F.
May 8, 2017 10 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool floor in need of cleaning.
#22 · Premises: emergency telephone provided −6
Observed phone number and listed did not match what 911 operator had on file. CDI phone number corrected.
May 12, 2016 18 demerits · 4 violations
Inspector comments: This is not a pool permit. Pool permit will be available within 2 to 3 business days on our website at meckpools.charmeck.org
Observed a hose in pool. Operator, Jeff Gaeckle, was asked if they are still filling up a pool and if they had a leak. Operator stated that they were not filling pool and it had been completed. Jeff stated that they had a leak in light nitch which had been repaired.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed some skimmer weirs damaged. CDI, operator repaired damaged skimmer weirs during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed entrance gate not self closing or self latching. CDI, operator repaired gate while on-site.
#22 · Premises: emergency telephone provided −6
Observed no dialing instructions or emergency pool phone number posted on emergency pool phone. CDI, operator provided signage during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck and not working. CDI, operator repaired flow meter during inspection.
May 8, 2015 14 demerits · 4 violations
Inspector comments: 11. Observed one ladder missing two slip resistent covers on stairs. Keep ladders in good repair. 24.. Observed stuck flow meter. Corrected PIC fix meter. Keep flow meter working in good repair.Permit issued.Permit will be available on county website in 3 days.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed 6 weirs missing from skimmers. Correction PIC provided new skimmers. Keep skimmers clean and in good repair.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed missing depth marker from pool deck and there was over 25ft between two surrounding depth markers. Correction PIC stenciled 4 inch depth marker. Depth markers shall be within 25ft.Observed no diving markers with red and white background only. Correction PIC provided international no diving markers. No diving markers shall be 25ft from adjacent markers.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some deck damage near shaded area of pool deck. Keep pool deck in good repair and free of trip hazards.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bags of chemicals on floor of chemical room. Keep chemicals up off the floor.
May 12, 2014 2 demerits · 1 violation
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Label direction of flow in pipes in pump/piping area.