‹ Back to search

6demerits

MUIRFIELD CONDOMINIUMS

7909 GREENSIDE COURT, Charlotte, NC 28277
Seasonal Swimming Pool · NC permit/State ID 2060500378
Latest result6 demerits
Last inspectedMay 19, 2026
Inspections on record15
On record sinceMay 29, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 May 29, 2014: 4Apr 30, 2015: 22Apr 28, 2016: 2Apr 19, 2017: 14Jun 8, 2017: 26Aug 1, 2018: 28May 2, 2019: 6May 5, 2020: 14Apr 23, 2021: 16Apr 27, 2022: 18May 25, 2023: 12May 29, 2024: 10May 21, 2025: 10May 5, 2026: 26May 19, 2026: 6
May 29, 2014Lower is betterMay 19, 2026

Inspections & violations

May 19, 2026 6 demerits · 2 violations
Inspector comments: Night swimming not approved. Inspection completed with CPO, Brandon Vaughn. Must replace detached/damaged skimmer rim prior to 2027 pool season per Hope M., PEHS Supervisor. Permit restriction: Pressure gauges used for flow reduction. Pump required at 3450 RPM. Gauges shall remain in place. Calculated TDH (pressure and vacuum combined) shall not be lower than 65’. TDH less than 65’ exceeds the maximum flow of the drain cover at 150 gpm. Suction hazard. Flow meter not approved for true flow.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Provide an NSF approved skimmer. Observed cracked/detached skimmer rim. Skimmer rim functional. **MUST REPLACE PRIOR TO 2027 POOL SEASON**
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Observed no functional lighting in pump room.

View this inspection on the county portal ›

May 5, 2026 26 demerits · 6 violations
Inspector comments: Must replace detached/damaged skimmer rim prior to 2027 pool season per Hope M., PEHS Supervisor. Night swimming not approved. Inspection completed with CPO, Brandon Vaughn.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface and floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed slight debris in skimmers. .2518(k) Provide an NSF approved skimmer. Observed cracked/detached skimmer rim. Skimmer rim functional. **MUST REPLACE PRIOR TO 2027 POOL SEASON**
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy longer than 30’. -CDI- CPO corrected.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed ringer not operable on emergency phone. CPO provided new phone but phone still not operational. **PERMIT DENIAL**
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter float stuck. -CDI- CPO corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Observed no functional lighting in pump room.

View this inspection on the county portal ›

May 21, 2025 10 demerits · 3 violations
Inspector comments: -PDSC verified -No Night Swimming -See permit for permit conditions
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaves on bottom and sides of pools View of bottom and main drain is not obfuscated.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in a few skimmer baskets. CPO empties skimmer baskets.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed damaged wall and toilet continuously running throughout inspection in bathroom on left hand side. All fixtures functional during inspection.

View this inspection on the county portal ›

May 29, 2024 10 demerits · 2 violations
Inspector comments: EHS observed pressure gauges 21psi and 20 Hg during inspection.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed PDSC form stating the equalizer covers are Aquastar 6hpha 101 2017 edition. EHS observed 2008 equalizer covers inside pool during inspection. CPO switched out equalizer covers to match PDSC form.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool lounge chairs closer than 6 ft to the pool surface. Chairs were pushed back to allow for 6ft deck clearance.

View this inspection on the county portal ›

May 25, 2023 12 demerits · 3 violations
Inspector comments: Ph was raised to 7.2
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
fitting in pool need to be re-done concrete is coming off
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate is self closing latching but is not in the best condition
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
fill in cracks around pool

View this inspection on the county portal ›

Apr 27, 2022 18 demerits · 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Clean off sides of pool and scum on depth markers.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Clean out debris from skimmer baskets
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Gate is not latching properly. CDI - New locking mechanism installed on return visit.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter bobber was stuck at start of inspection. CDI - Operator repaired flow meter.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap between pipe and backwash pit. Maintain an air gap between top of pit and bottom of pipe.

View this inspection on the county portal ›

Apr 23, 2021 16 demerits · 3 violations
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. Corrected during time of inspection to 10ppm chlorine.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Corrected during time of inspection to 7.2.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface.

View this inspection on the county portal ›

May 5, 2020 14 demerits · 5 violations
Inspector comments: No night swimming permitted.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed side entrance gate not consistantly self-closing / self latching and catching growing vegetation on ground prevent consistant self-closure of gate. CDI, vegetation removed to allow gate to be self-closing / self latching. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed some areas of fense below 48" in height. Pool built prior to 2010. Fencing shall be at least 48" in height.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed pool furniture 4 ft. 5 inches from edge of pool deck. CDI, furniture relocated to prevent potential trip hazard.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(6) Provide sufficient lighting in chemical storage room. Observed lights not working.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at backwash line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed no soap in dispenser at handwashing sink or disposable towels available located in men's restroom.

View this inspection on the county portal ›

May 2, 2019 6 demerits · 2 violations
Inspector comments: Observed a stack of wood directly outside of the fence that could be used as a foothold. Pool built prior to 2010.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Perimeter fencing ranging from 41" to 45" in height. Pool built prior to 2010. Fencing shall be at least 48" in height.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Pool built prior to 2010. Lighting not operable in pump room. Provide lighting. Repeat non-compliance.

View this inspection on the county portal ›

Aug 1, 2018 28 demerits · 10 violations
Inspector comments: 7 - Observed new paint for swimming pool. (c) Pool finish, including bottom and sides, shall be of white or light colored material determined visually to contrast least with a value of gray whiter than 50 percent black on an artists gray scale, or shown by reflectance testing to reflect more than 50 percent of visible light. Provide LRV values for pool finish. If less than 50%, required repair before 2019 operating season. Provide within 24 hours.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Some damage to skimmer casing at 3 1/2 ft. Does not affect functionality of skimmer. Monitor damage and replace/repair if continues to worsen.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Painted No Diving markers <4" in height. Corrected during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Some rust on ladders. Keep ladders in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Front gate with 2 1/2" under on left side. Corrected during inspection to 2". Perimeter fencing ranging from 41" to 45" in height. Pool built prior to 2010. Fencing shall be at least 48" in height.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Pool furniture <6 ft from pool. Corrected during inspection. Deck damage near 4 ft skimmer. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Pool built prior to 2010. Lighting not operable in pump room. Provide lighting. Repeat non-compliance.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Labeling beginning to wear off on piping in pump room. Clearly identify all pipes with color codes/labels.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in mens restroom. Provide soap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Check valve without proper cross connection. Pool originally constructed with backflow installed for fill line. backflow. Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, a pipe-applied atmospheric vacuum breaker (ANSI/American Society of Sanitary Engineering No. 1001-1971), a pressure type anti-siphon vacuum breaker (ANSI/ASSE No. 1020-1976), or a reduced-pressure principle backflow preventer (ASSE No. 1013-1979, American Water Works Association No. C506-1978), which are hereby adopted by reference in accordance with G.S. 150B- 14(c) or equivalent.

View this inspection on the county portal ›

Jun 8, 2017 26 demerits · 8 violations
Inspector comments: 13 - General Comment: Contrasting color band >1" from edge of step. Step appears to have been painted previously. Repair before 2018 season or permit will not be issued. 15 - General Comment: Observed some weather deterioration on ring buoy grab rope and rope. Recommend replacing ring buoy with USCG approved buoy and provide 30 ft rope. Onsite visit to pool. Recommend treating pool per CDC guidelines by hyperchlorinating pool before opening to public. Per local ordinance, a lifeguard is not required; however, no pool shall be used when a lifeguard or other person is not present. Pool is not permitted for Night Swimming. Pool hours not posted. Recommend posting pool hours visible to the public upon entrance to the pool. Post permit visible upon entrance to the pool. Permit can be found on our website at http://meckpools.charmeck.org.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some minor chipping around floor returns on pain. Repair as needed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Perimeter fencing ranging from 41" to 45" in height. Pool built prior to 2010. Fencing shall be at least 48" in height. Gates into pool less than 48" in height. Repair gates to 48" or greater. Intent to Suspend issued. Gate near deep end of pool with greater than 4"x4" opening towards top of gate. Repair to assure no openings greater than 4". Intent to Suspend issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Pool furniture less than 6 ft to pool in some locations. Assure at least 6 ft clearance around the pool.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth markers on wall beginning to fade. Replace before 2018 season. Still visible to public.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pool has switched to salt system. Install NSF approved chlorinator as back-up. Intent to Suspend issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals stored in pump room. Pool built prior to 2010 and was approved as is. Lighting not operable in pump room. Provide lighting.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Pool built prior to 2010. Provide air gap at pit.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
No soap in men's restroom. Provide soap. Paper towel dispenser stuck in women's. Provide hand drying device.

View this inspection on the county portal ›

Apr 19, 2017 14 demerits · 3 violations
Inspector comments: Observed contrasting tile bands at pool steps 2" from edge of steps. This must be corrected before the permit to operate for 2018 will be issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed height of exterior fence to be less than 45 " in several areas, even after scraping away loose pine straw on ground.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lounge chairs less than 6 ' from edge of pool. Trip hazard. Chairs moved while on site.
#22 · Premises: emergency telephone provided −6
Observed address and pool phone number faded and obscure. Corrected while on site by placing white duct tape over old lettering and replacing with contrasting magic marker lettering.

View this inspection on the county portal ›

Apr 28, 2016 2 demerits · 1 violation
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repair wall and ceiing in pump room. Observed water on floor. No leak.

View this inspection on the county portal ›

Apr 30, 2015 22 demerits · 6 violations
#3 · Water quality: pool water pH −6
pH reading 6.8 at initial check. pH brought up to 7.2 during my inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris on pool deck.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Trip hazzard. Chairs 3' from the pools edge.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
No sign present. New sign prohibiting glass containers and pets in pool area posted during my inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room. Chemicals stored on the floor in wet area.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
No shower sign on premesis. New sign posted during my inspection.

View this inspection on the county portal ›

May 29, 2014 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Replace missing tiles in pool wall repair coping.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “MUIRFIELD CONDOMINIUMS” or State ID 2060500378). Inspection type (routine vs. follow-up) is not published in the county's data.