16demerits
OAKHILL APARTMENTS
831 BEATY STREET, Davidson, NC 28036
Seasonal Swimming Pool · NC permit/State ID 2060500392
Latest result16 demerits
Last inspectedJun 2, 2026
Inspections on record12
On record sinceJul 17, 2013
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jul 17, 2013Lower is betterJun 2, 2026
Inspections & violations
Jun 2, 2026 16 demerits · 3 violations
Inspector comments: PERMIT RESTRICTIONS:
Flow meter must remain operable. Flow shall not exceed 100 gpm due to drain cover flow restriction. Suction hazard.
Night Swimming not Permitted
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.2 at start of inspection. CDI - Pool operator corrected pH during inspection. Follow up testing showed pH at 7.4 and 7.5.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed a test kit without method to test cyanuric acid.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone call back number incorrect on posted signage. Signage had a "9" instead of "4". CDI - Emergency phone number was corrected.
May 21, 2025 24 demerits · 5 violations
Inspector comments: PERMIT RESTRICTION:
- Flow meter must remain operable. Flow shall not exceed 100 gpm due to drain cover flow restriction.
- NIGHT SWIMMING IS NOT PERMITTED.
- CPO: Elvin Velez present during operational permit inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8.- Observed pH = 8.2. Fixed during inspection at 7.2
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.- Observed a test kit has an expiration date of 2023-2024. Obtain a new kit.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Observed double sliding glass doors of maintenance room lead out to a pool deck. There is a door from a guest laundry room to maintenance room and lead out to a pool deck. CDI- Audible alarms installed and work on both double doors at the time of inspection.
#19 · Premises: signs prohibit glass containers or pets in pool area −4
.2530(d) Provide a sign prohibiting pets and glass containers in the pool area.
NOTE: The pool sign starts to deteriorate, may need a replacement one before the end of the season.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.- Observed faded telephone number written on the phone door. Corrected during inspection.
Jun 26, 2024 0 demerits · 0 violations
No violations were recorded for this inspection.
Jul 26, 2023 2 demerits · 1 violation
Inspector comments: Inspection conducted with CPO Elvin Velez.
Pre-permit items from previous inspection have been corrected.
Permit issued with the following restrictions:
No night swimming
Flow meter must remain operable. Flow shall not exceed 100 GPM due to drain cover flow restriction. Observed flow meter at 105 GPM today, which is within margin of error for this flow meter at 100 GPM.
Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Jul 19, 2023 26 demerits · 6 violations
Inspector comments: Inspection conducted with CPO Elvin Velez.
Pre-permit inspection did not pass.
2)
6)
There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.
#2 · Water quality: disinfectant residual provided by −6
Observed some chlorine tabs in the skimmer. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Pre-permit item.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Pressure gauge on Vac Alert SVRS system not functioning. .2539(b) Pools with single main drain or drains <36" apart shall provide a safety vacuum release system (SVRS) or other methods of preventing bather entrapment. Must be installed and operating per manufacturer’s instructions. - Pre-permit item.
No place on log sheet for SVRS testing. .2539(b) SVRS systems shall be tested monthly per manufacturer’s instructions. - Corrected.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Hole in the deck by 5ft mark. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item.
#18 · Premises: lifeguards present or warning signs posted −4
Missing a word from safety signage. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Jun 6, 2019 8 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring 50ft (needed) 30ft; CDI rope cut to 30ft.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
REPEAT
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed no ventilation in chemical/pump room.
Jun 22, 2018 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck in need of repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no ventilation in pump room.
Jun 2, 2017 18 demerits · 5 violations
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0.4 ppm. Advised to keep chlorine levels at 1.0 ppm at the least. CDI - Facility uses the PENTAIR RAINBOW MODEL 300 chlorinator. Pool Operator Elvin Velez provided more chlorine pucks to the chlorinator. Quality of water is currenlty at 3.0 ppm.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in surface skimmers. Advised to keep clean. Cleaned out during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed recess ladders loose. Advised to tighten.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed lounge chairs within 6' of pool deck. CDI - relocated lounge chairs to where no deck obstruction is occuring.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water in pump room. Observed no ventilation in pump room where chemicals are stored.
Jun 23, 2016 14 demerits · 4 violations
Inspector comments: Observed no data plate on pump except for pump motor at 2 HP. K Wilson stated pump is approved.
#2 · Water quality: disinfectant residual provided by −6
Observed chlorine at 0ppm. Facility immediately suspended and placed on E status.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck damage in several locations. Repair damage.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No ventilation in pump room. Provide continuous forced ventilation or cross ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
Aug 26, 2015 28 demerits · 8 violations
Inspector comments: 22 - General Coment - 911 has 831 Beaty Street as address. When Polaris viewed, no assigned address listed. 835 Beaty St is building located across the street. Pool signage corrected to correct address. Will update in Polaris through GIS. Immediate Suspension issued for chlorine shock and pool rope.
#2 · Water quality: disinfectant residual provided by −6
Operator stated he had to shock pool in order to raise chlorine. Done two hours prior. Do not shock pool and keep pool open. Pool must be closed when chlorine put directly into pool. Immediate Suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No log book. Record chlorine, pH and main drain check daily. Alkalinity and acid weekly.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladders >6" from pool wall. Maintain between 3" and 6" between ladder handrail and wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope damaged on ring buoy. Replace with 30 ft rope. Immediate Suspension issued.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck damage in several locations. Repair damage.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No ventilation in pump room. Provide continuous forced ventilation or cross ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap. Backwash line clear sight glass made of flexible piping. Provide hard PVC pipe.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No paper towels in restroom. Provide paper towels.
Jun 25, 2014 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed cracks around the coping joint - recommend caulking around the entire perimeter
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
provide a shower sign at the entrance of the pool
Jul 17, 2013 26 demerits · 8 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no records kept. Log book present. Maintain chlorine, pH, main drain check daily and CYA and alkalinity weekly.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed etching on pool floor. Keep in good repair.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmers with build-up. Keep clean.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Observed no overflow grate. New grate has been ordered. Damaged grate has been removed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed >4" under fence in some areas. Maintain 4" or less.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no ventilation in pump room. Drywall has been installed but no change of room. Provide cross or forced ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
ObserveId no air gap at backwash line to pit. Pit not visible. Provide air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no shower sign posted. Post visible upon entrance to pool.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “OAKHILL APARTMENTS” or State ID 2060500392). Inspection type (routine vs. follow-up) is not published in the county's data.