‹ Back to search

4demerits

OAKS CONDOMINIUMS

1531 LANSDALE DRIVE, Charlotte, NC 28205
Seasonal Swimming Pool · NC permit/State ID 2060500394
Latest result4 demerits
Last inspectedJun 1, 2026
Inspections on record12
On record sinceJun 5, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01428 Jun 5, 2014: 12Jun 10, 2015: 6Jun 9, 2016: 12Apr 20, 2017: 0May 11, 2018: 8May 17, 2019: 24May 26, 2021: 28Apr 26, 2022: 12Apr 3, 2023: 10Apr 24, 2024: 6Apr 3, 2025: 8Jun 1, 2026: 4
Jun 5, 2014Lower is betterJun 1, 2026

Inspections & violations

Jun 1, 2026 4 demerits · 1 violation
Inspector comments: PERMIT RESTRICTION - FLOW METER MUST REMAIN OPERABLE. FLOW SHALL NOT EXCEED 119 GPM DUE TO FLOW RESTRICTION OF DRAIN COVERS. SUCTION HAZARD. NO NIGHT SWIMMING.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed missing eye of inlet. CPO corrected during inspection and replaced with new eye.

View this inspection on the county portal ›

Apr 3, 2025 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
clean pool of debris
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
clean skimmers

View this inspection on the county portal ›

Apr 24, 2024 6 demerits · 2 violations
Inspector comments: Flow meter exceeding 120 gallons per minute for schedule 40. Corrected on site by CPO. Sprinkle. Valves to be throttled in order for flow not to exceed 110 gallon per minute schedule 40. This message has been posted on the records book the filter and the wall.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight debris on pool floor
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Maintain breakpoint rope and floats in good repair. Observed no break rope with buoys. CDI installed

View this inspection on the county portal ›

Apr 3, 2023 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed slight debris on pool floor
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one return missing. CPO replaced
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no clear air gap

View this inspection on the county portal ›

Apr 26, 2022 12 demerits · 3 violations
Inspector comments: No Night Swimming.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Observed 9ft deep end return missing eyeball fitting. Corrected during inspection: Eyeball fitting replaced.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed 60ft throw rope. Corrected during inspection: CPO provided 45ft throw rope by the end of the inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at back wash.

View this inspection on the county portal ›

May 26, 2021 28 demerits · 8 violations
Inspector comments: CPOs Eric and Alex were present during the pool inspection. No signature occurred due to covid19 pandemic. Issuance of the pool permit does not negate meeting requirements of executive order 195 or subsequent orders in effect unless such orders are rescinded or suspended by another applicable order. No night swimming shall occur until another visit is made by the regulatory authority for approval.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. - Observed debris on pool floor. EHS was able to verify main drains and still see a majority of the pool floor. CDI- CPO started cleaning the pool during the inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in skimmers during the inspection. CDI- CPO cleaned the skimmers during the pool.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. - Observed no breakpoint safety rope across the pool. CDI- CPO provided breakpoint rope by the end of the inspection.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Observed returns missing protective plastic. CDI- CPO repaired during the inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed 60ft throw rope. CDI- CPO provided 45ft throw rope by the end of the inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Mesh shall not exceed 2.25" square. Provide no openings in fence and/or gate greater than 4"x4". - Observed mesh fence detached from pole near 3ft side. CDI- CPO repaired fence during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. - Observed standing water in pump room.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - Observed no back flow prevention device on hose bib located near the pool.

View this inspection on the county portal ›

May 17, 2019 24 demerits · 6 violations
Inspector comments: Replace ring buoy by next year.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Clean skimmers
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
inlet missing eyeball, screw back in *fixed during inspection
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
throw rope was incorrect length *fixed during inspection
#18 · Premises: lifeguards present or warning signs posted −4
no lifeguard signs placed around pool but corrected during inspection *fixed during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
keep chemicals off floor and place on pallet
#19 · Premises: signs prohibit glass containers or pets in pool area −4
no signs --glass/pet *corrected during inspection

View this inspection on the county portal ›

May 11, 2018 8 demerits · 2 violations
Inspector comments: Allie Neal was present for inspection, report emailed after completion.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Vacuum line cover observed to have fallen off into the pool, replaced by operator during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on the floor of the pump room due to slight leak coming from the pump system.

View this inspection on the county portal ›

Apr 20, 2017 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 9, 2016 12 demerits · 2 violations
#3 · Water quality: pool water pH −6
pH @6.9 CDI to 7.2
#22 · Premises: emergency telephone provided −6
Phone not working properly. CDI new phone purchased.

View this inspection on the county portal ›

Jun 10, 2015 6 demerits · 2 violations
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
2 inlet eyes and vaccum inlet missing. Corrected while on site.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
Lettering and valves have faded. Corrected while on site.

View this inspection on the county portal ›

Jun 5, 2014 12 demerits · 4 violations
#3 · Water quality: pool water pH −6
pH 7.0. Corrected to 7.2.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Bottom rung on ladder broken. Repair.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Floats on safety rope > 5' apart. Floats shall be no more than 5' apart.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash not discharged through an air gap.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “OAKS CONDOMINIUMS” or State ID 2060500394). Inspection type (routine vs. follow-up) is not published in the county's data.