‹ Back to search

12demerits

OLDE GEORGETOWNE SWIM CLUB

7930 WHISTLESTOP RD, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060500395
Latest result12 demerits
Last inspectedMay 12, 2026
Inspections on record13
On record sinceMay 9, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01122 May 9, 2014: 6May 8, 2015: 22Apr 19, 2016: 14Apr 27, 2017: 10Apr 25, 2018: 20Apr 10, 2019: 12Jun 1, 2020: 6Apr 6, 2021: 0Apr 27, 2022: 8May 15, 2023: 8May 10, 2024: 4Apr 9, 2025: 4May 12, 2026: 12
May 9, 2014Lower is betterMay 12, 2026

Inspections & violations

May 12, 2026 12 demerits · 3 violations
Inspector comments: Night swimming approved, as long as all lights are operable Lifeguard required
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw ropes on ring buoys 56’ and 58’. CDI- both cut to 50’
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed bent vertical >4” on fence in covered grill area. Fence broken from brick support and bottom horizontal damaged (side with road). CDI-fence fixed .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate not self closing self latching (near pump room). CDI-gate fixed
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventers on any hose bibs.

View this inspection on the county portal ›

Apr 9, 2025 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed minor debris on pool floor. Clean as needed.

View this inspection on the county portal ›

May 10, 2024 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris., Pool floor stained in need of resurfacing.

View this inspection on the county portal ›

May 15, 2023 8 demerits · 3 violations
Inspector comments: Q status items observed to be fixed.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
slight leaf debris present on pool floor, staff were in process of cleaning during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose ladder near the pump room.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
observed presence of water on the floor of the pump room. Leak from the chlorination system as noted by A. Bumgarner had been repaired, no equipment was observed leaking during inspection.

View this inspection on the county portal ›

Apr 27, 2022 8 demerits · 2 violations
Inspector comments: Diving boards not permitted for use until verification of proper installation of supports can be made.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool floor in need of cleaning.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers in need of cleaning.

View this inspection on the county portal ›

Apr 6, 2021 0 demerits · 0 violations
Inspector comments: No violations. Covid 19 restrictions, no signature required.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jun 1, 2020 6 demerits · 2 violations
Inspector comments: Verified PDSC information. Observed slow leak on piping at first 90 degree elbow after pump discharge. Observed slow leak from sand filter bottom cleanout. Pool will not be issued a 2021 with out fixing these items. No signature due to COVID19 social distancing requirements.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Observed safety rope present but not in place at time of inspection. .2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gaps greater than 1/2" on new gate insalled between fence post and gate. Corrected during inspection. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.

View this inspection on the county portal ›

Apr 10, 2019 12 demerits · 3 violations
Inspector comments: Pool has not been approved for night swimming. Information provided as to how to have lighting observed. Ensure that permits are placed so they are visible at all times. General comment: 17. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Covers for flag poles needed when pools not in place. Cover/ barrier for electrical box in center of pool deck needed. CPO advised will replace.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. No safety rope and colored floats provided initially. CDI- CPO Katie Buttcher provided.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. No red life quard floats provided during inspection. CDI- CPO replaced
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Rear access gate was not self closing and self latching. CPO replaced hinge and corrected.

View this inspection on the county portal ›

Apr 25, 2018 20 demerits · 6 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfecant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No daily records sheets in pool book. Katie Buttcher provided while on site.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed 4 Aquastar 6HP covers and 3 Aquastar 4HP covers. Approved form calls for 7 6HP covers. Corrected while on site. Katie Buttcher obtained correct covers and installed.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2517(a)3 Provide labeling affixed to diving equipment. Observed no labeling on diving equipment. Keep ladders and handrails in good repair. Ladders and handrails loose.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. One gate not self-closing. CDI- repairs made on site during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemical area has cros-ventilation blocked.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Only hose bib located has no back flow prevention.

View this inspection on the county portal ›

Apr 27, 2017 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
Pool pH at 6.8 at beginning of inspection . CDI pH adjusted to 7.4
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed pool floor needs cleaning.

View this inspection on the county portal ›

Apr 19, 2016 14 demerits · 4 violations
Inspector comments: \This is not a pool permit. Pool permit will be available within three business days and will be available at meckpools.charmeck.org
#19 · Premises: signs prohibit glass containers or pets in pool area −4
Observed no pool signage stating that "Children should not use the swimming pool without adult supervision: and "Adults should not swim alone" in letter at least 1 inch high with exact wording. CDI, operator provided signage.
#22 · Premises: emergency telephone provided −6
Observed no dialing instructions on emergency pool phone sign. CDI, dialing instruction provided.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed less than required walkway between equipment in equipment room.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no shower sign posted. Sign posted during inspection.

View this inspection on the county portal ›

May 8, 2015 22 demerits · 7 violations
Inspector comments: 8. Observed skimmers soiled with debris and weir missing. Keep skimmers clean and in good repair. 24. Observed one of the flow meters stuck. Keep flow meters in good repair.Permit issued.Permit will be available on county website in 3 days.
#1 · Water quality: water clear enough to clearly see bottom of pool and pool drain −6
Observed pool that was cloudy but was able to see bottoem of pool, main drains and contrasting bands.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladders that were loose fitting. Keep ladders and handrails in good repair.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck with deep cracks on side of pool deck. Keep deck in good repair and free of trip hazards.
#18 · Premises: lifeguards present or warning signs posted −4
Observed pool sign missing statement about adults not swimming alone and statement about children not swimming without supervision. Corrected PIC brought signs with correct verbage. Proper signage shall be psoted on pool deck.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed less than 3ft clearance in equipment room. Atleast 3 feet clearance in equipment room.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed pool without air gap for backwash, sight glass in place.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no shower sign posted upon entrance of pool. Correction PIC provided shower sign.

View this inspection on the county portal ›

May 9, 2014 6 demerits · 3 violations
Inspector comments: Permit issuedPermit available on website with in 3 business days.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tighten loose ladders. Observed 3 loose ladders
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors in bathrooms should be shatter proof.
#31 · Dressing and sanitary facilities: sewage disposed of in a properly operating sewage system −2
Appears that the backwash line is discharged into storm drain behind pump room building.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “OLDE GEORGETOWNE SWIM CLUB” or State ID 2060500395). Inspection type (routine vs. follow-up) is not published in the county's data.