4demerits
JADE CHARLOTTE, THE
5600 PACES GLEN AVENUE, Charlotte, NC 28212
Seasonal Swimming Pool · NC permit/State ID 2060500402
Latest result4 demerits
Last inspectedApr 30, 2026
Inspections on record11
On record sinceMay 29, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 29, 2014Lower is betterApr 30, 2026
Inspections & violations
Apr 30, 2026 4 demerits · 1 violation
Inspector comments: Inspection conducted with Alex Estrada.
No night swimming.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Fence is <48” in one location. Pool constructed prior to 2010 with original fence.
Apr 16, 2025 10 demerits · 3 violations
Inspector comments: Night swimming not permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed minor debris in skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder without rubber end caps.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed gaps underneath fence greater than 4”, in some areas up to approximately 10 inches. Pool was constructed Pre-May 2010. REPAIR.
Apr 15, 2025 24 demerits · 6 violations
Inspector comments: For re-inspection contact Main office at 980-314-1620. Re-inspection fee of $100 required.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit with expired reagents. CPO provided new reagents.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets with debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder missing rubber caps.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed no cap or cover on vacuum line. Permit denial issued.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding 35ft. CDI: Rope length was adjusted to 35ft during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed gaps underneath fencing greater than 4” and in some areas up to approximately 10 inches. Pool was constructed Pre-May 2010. REPAIR.
May 2, 2024 16 demerits · 4 violations
Inspector comments: Submitted PDSC form indicates four skimmers w/ equalizers. Observed five skimmers with equalizers. Make and models of equalizers and drain covers correct. Permit will be issued today. Pool will have 2 weeks from today to submit accurate PDSC form for approval. Failure to do so may result in immediate suspension of permit.
Kelvin Martinez present during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris in skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder with missing rubber end caps.
Observed ladder not securely attached to pool deck. Concrete degraded. Spot repair needed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed rope at 30 feet. CDI- adjusted to 35 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed several sections of fencing with greater than 4 inches and up to approximately 11 inches underneath fencing. Recommend repairing to provide no more than 4 inches under fencing.
Jun 6, 2023 16 demerits · 4 violations
Inspector comments: Inspection completed with Jonathan Gray present.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder with missing rubber end caps.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed no cap/cover on vacuum suction line in pool wall. Suction line was not active during inspection. CDI- line was plugged.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed rope at 50 feet. CDI- adjusted to 35 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed several sections of fencing with greater than 4 inches and up to approximately 9 inches underneath fencing. Recommend repairing to provide no more than 4 inches under fencing.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed one area of fencing under stairs to office where fencing was less than 48 inches as measured from outside of fencing. CDI- additional barrier was installed to correct.
May 17, 2019 16 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing or damaged skimmer basket.
Observed slight break in skimmer basket on right side, nearest skimmer. The skimmer basket still functions well. Violation is not severe enough to prevent issuance of permit but does need to be addressed. CPO informed and will replace immediately.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions.
Provide plastic end caps on deep end ladder to prevent pool wall scraping.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
Ring buoy provided was not USCG approved. CDI. CPO obtained USCG buoy from another location that met requirements.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Observed a couple of areas in concrete grout between brick surrounding pools where grout is missing. CPO to regrout this afternoon and has already been addressed. Violation is not severe enough to prevent issuance of permit but does need to be addressed.
May 16, 2018 6 demerits · 1 violation
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy was not coast guard approved. A new coast guard approved buoy was bought and placed on the pool deck. CDI
Apr 26, 2017 4 demerits · 2 violations
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513 Backwash must be discharged through an air gap. No air gap in back wash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526 Soap and paper towels must be provided at handwashing sinks. No soap in men's room.
Jun 6, 2016 14 demerits · 4 violations
#3 · Water quality: pool water pH −6
pH was 6.8. Must be kept between 7.2 to 7.8.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
(Eyeball) Return jet missing. Replace
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap in back wash
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap or paper towels in either restrooms. Must provide soap and paper towels in restrooms.
Jun 26, 2015 10 demerits · 3 violations
Inspector comments: #11 General Comment: Need bumppers on ladder to protect pool walls.
#27 General Comment: Increase air gap for backwash
#13 · Pool maintenance: contrasting band on steps and benches −4
Contrasting band is greater than 1 inch from leading edge in places. This should be corrected the next time pool is drained.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Noted some areas of deck are chipping/breaking (around ladder/handrail holes)
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Provide shower sign in public area (Shower before entering)
May 29, 2014 8 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
All weirs shall be present and in good repair. Observed two out of 5 weirs missing.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
All gates shall be self latching. Observed one of the gates unable to self latch when closed. CDI-gate was repaired, all gates now are self latching.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “JADE CHARLOTTE, THE” or State ID 2060500402). Inspection type (routine vs. follow-up) is not published in the county's data.