0demerits
QUEENS TOWERS
1300 QUEENS ROAD, Charlotte, NC 28207
Seasonal Swimming Pool · NC permit/State ID 2060500448
Latest result0 demerits
Last inspectedApr 15, 2026
Inspections on record13
On record sinceJun 3, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 3, 2014Lower is betterApr 15, 2026
Inspections & violations
Apr 15, 2026 0 demerits · 0 violations
Inspector comments: PDSC form was uploaded and approved for 2026 season. Drains were replaced and match PDSC form.
Permit restriction - flow meter must remain operable. Flow not to exceed 119 gpa due to flow restriction of main drains. Suction Hazard. Phone does not receive phone calls from Verizon. Must be hard line that calls phone back for non Verizon carrier.
Pool is open for the 2026 season.
No night swimming.
No violations were recorded for this inspection.
Apr 10, 2025 6 demerits · 1 violation
Inspector comments: Permit restrictions: Flow meter must remain operable. Flow not to exceed 119 GPM due to flow restriction of main drains.
Note: Phone does not receive phone calls from Verizon. Must be hard line that calls phone back or non-Verizon carrier. Verified by Tim Dutcher on AT&T phone that number dialed back to pool phone.
No night swimming.
Pump room does not have a pit for backwash discharge but does have a sight glass to view backwash. Backwash must be done in segments in order to drain properly and not flood pump room.
Inspection conducted with CPO Pierce Sawyer.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed PH level at 7.0. CDI: corrected to 7.3 during inspection.
Apr 2, 2024 8 demerits · 2 violations
Inspector comments: Emergency phone not able to receive calls from Verizon phone. Must use a landline to call. 911 was able to call back.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed cracks appearing by ladders and steps that can lead to a trip hazard. Observed cork deck material starting to wear away near one of the 10ft depth markers. Deck repair needed.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(e) Provide a spare basket for pump. Observed no spare pump basked. -CDI- CPO provided one.
May 8, 2023 4 demerits · 1 violation
Inspector comments: Inspection completed with Pierce Sawyer
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Observed chair preventing 5ft walking clearance at pool.
.2537(2) Decks shall be kept in good repair. Observed cracks appearing by ladders and steps that can lead to a trip hazard. Deck repair needed.
Apr 4, 2022 6 demerits · 2 violations
Inspector comments: No night swimming permitted.
Pool operation hours are dawn until dusk per operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed area of gate on left hand side near parking lot where steps can act as a foot step for entrance into pool over fence. Operator will provide a piece of fiberglass to measure at least 48” from possible footstep.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Provide air gap for filter backwash.
Apr 13, 2021 6 demerits · 2 violations
Inspector comments: No night swimming permitted.
Pool operation hours are dawn until dusk per operator.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Hand Railing on stairs at far fencing creates a foothold. Pre-2010 construction.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap
Apr 16, 2020 0 demerits · 0 violations
Inspector comments: Night swimming has not been permitted.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.q
No violations were recorded for this inspection.
Apr 4, 2019 12 demerits · 3 violations
Inspector comments: Small area around pool ladder anchor needs to be filled in. Not sharp or hazardous. Needs to be fixed
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Ring buoy needs to be replaced. CDI
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Railing near west side of pool creates a foot hold. Railing within 18" of fence.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for back wash.
Apr 6, 2018 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris floating in pool.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed one skimmer basket broken.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on backwash line.
Apr 4, 2017 2 demerits · 1 violation
Inspector comments: Pre-permit inspection. Permit approved.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on backwash pipe.
Apr 14, 2016 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 8, 2015 2 demerits · 1 violation
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap on back wash line. Provide an air gap on back wash line. Blown light bulb replaced in equipment/chemical room at time of inspection.Pierce Sawyer present at time of inspection.
Jun 3, 2014 6 demerits · 2 violations
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Pool fill spout located on deck and not located near a ladder or diving board. All fill spouts must be located within 6" of hand rails or beneath diving boards. INTENT TO SUSPEND ITEM
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap on backwash line. Provide an air gap on backwash line.Noah Abercrombie and Gary Knight present.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “QUEENS TOWERS” or State ID 2060500448). Inspection type (routine vs. follow-up) is not published in the county's data.