18demerits
RADBOURNE
3325 RADBOURNE BLVD, Charlotte, NC 28213
Seasonal Swimming Pool · NC permit/State ID 2060500449
Latest result18 demerits
Last inspectedApr 14, 2026
Inspections on record13
On record sinceApr 25, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 25, 2014Lower is betterApr 14, 2026
Inspections & violations
Apr 14, 2026 18 demerits · 4 violations
Inspector comments: Construction date: 1/1/1990
Rope length: 50’
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed 5 skimmers full of debris. CPO cleaned out during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. New Rope measuring greater than 50’. CPO cut and knotted rope to required length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Light box providing foothold on exterior of fence due to being bent towards fence. CPO corrected during inspection by repairing structure.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Trip hazards include white drain strip and pool umbrella hole. CPO corrected during inspection by drilling strip down and plugging hole.
May 13, 2025 0 demerits · 0 violations
No violations were recorded for this inspection.
Apr 19, 2024 10 demerits · 3 violations
Inspector comments: No night swimming.
Inspection conducted with CPO Danielle
No permit restrictions.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 1 missing eye ball fitting. CDI: replaced.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck to bottom. CDI: changed out for new meter and now functioning properly.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors in restrooms not shatterproof.
.2526(m) Keep restrooms and fixtures clean and in good repair. Repair restroom stall door in women’s restroom.
May 19, 2023 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors in restroom not shatterproof.
Apr 13, 2022 18 demerits · 6 violations
Inspector comments: 24. Recommend 60 rpm setting for variable speed pump, pump set at 55 rpm at time of inspection
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool walls & floor to be kept free of debris
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder tightened during inspection
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
junction of 2 deck drains - fill space where deck paver has sunk; pool edge corner near pool steps needs to be filled in
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Two door alarms installed on clubhouse doors during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Fan not working, ventilation is required; light not working in chemical storage room
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors to be of shatter-proof construction
May 14, 2021 0 demerits · 0 violations
Inspector comments: No violations were observed during today's visit
NOTE: Verified that there was support under the pump, new pump is EQK750, 7 1/2 HP. Main drain and skimmer piping is 6" and return piping is 4". Counted 19 returns on the walls. Drain covers, equalizer line covers and filters were all correct.
No violations were recorded for this inspection.
May 13, 2020 4 demerits · 1 violation
Inspector comments: No night swimming
permit issued.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets full of debris. CDI- pool manager removed debris
May 6, 2019 16 demerits · 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Pool floor has some debris that needs cleaning.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Buoy rope was more than 50 ft. PO corrected rope to 50 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528 Observed two places outside of fence with foot holds, a HVAC unit and a water spigot. Pre 2010 permit, no permit action.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap from height of drain pit.
GENERAL COMMENT: Permit issued. Night swimming permitted. Pool is to be lifeguarded.
Apr 26, 2018 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris floating in pool. Needs to be cleaned.
May 2, 2017 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
HVAC unit beside fence. Fence should be 48" or higher. Balcony part of pool area at gates do not meet requirements. Keep doors to clubhouse on balcony locked or make them self closing and self latching.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Keep a trash can in restrooms.
Apr 29, 2016 10 demerits · 3 violations
Inspector comments: 21) Observed underwater lighting secure.Go to our website, Meckpools.charmeck.org to print permit and post a copy in the pool area.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Baskets full. Clean regularly.Observed weirs now functioning.,
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
HVAC unit right beside fence. Fence shall be at least 48" high. Balcony part of pool area as gates do not meet requirments.Doors to clubhouse shall be locked at all times or be self-closing and self-latching.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light in pump room not working. Provide lighting.
Jun 23, 2015 12 demerits · 2 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook screws were reverved so the nuts were toward the outside of the hook. Pool does have lifeguards.
#22 · Premises: emergency telephone provided −6
Facility has two phones. The phone outside the guard room did not have a dial tone. The phone inside the guard room was working properly with proper signage. Repair or remove outside phone.
Apr 25, 2014 16 demerits · 4 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook screws facing inside body hook which is safety risk. Screws corrected to outside. Buoy rop longer than 50 ft, rope length corrected to 50 ft.
#22 · Premises: emergency telephone provided −6
Emergency phone in office has no sign alerting swimmers of the phone location. Sign posted during inspection with phone location.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap on backwash pipe from height of pit. Maintain an air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Bathroom water obs. at 120 degrees, maintain at 110 degrees max. Mirrors in restrooms need to be shatterproof.General Comment: 7) Observed couple small areas on pool wall that are peeling and need repair. 13) Stairs have 3-4" gap from wall to contrasting bands, need to meet the pool wall, needs correcting by next pool season.Permit Issued.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “RADBOURNE” or State ID 2060500449). Inspection type (routine vs. follow-up) is not published in the county's data.