‹ Back to search

4demerits

RIVERPOINTE HOMEOWNERS

15941 RIVERPOINTE DRIVE, Charlotte, NC 28278
Seasonal Swimming Pool · NC permit/State ID 2060500478
Latest result4 demerits
Last inspectedApr 20, 2026
Inspections on record14
On record sinceMay 9, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 May 9, 2014: 10May 15, 2015: 12May 20, 2016: 18May 10, 2017: 6Apr 18, 2018: 6Apr 17, 2019: 0May 21, 2020: 2May 28, 2021: 0Apr 28, 2022: 6Apr 25, 2023: 0Apr 19, 2024: 0Apr 30, 2024: 0Apr 24, 2025: 10Apr 20, 2026: 4
May 9, 2014Lower is betterApr 20, 2026

Inspections & violations

Apr 20, 2026 4 demerits · 1 violation
Inspector comments: Approved for Night swimming - 7/22/2025 Lights for night swimming are on timer. EHS will conduct visit during hours light are on to ensure lighting is sufficient due to one large light fixture not working. Pool will open May 2nd, EHS visit prior to opening.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed furniture not allowing 6 ft of clearance around the pool. CDI - Pool furniture relocated.

View this inspection on the county portal ›

Apr 24, 2025 10 demerits · 2 violations
Inspector comments: Night swimming not approved.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope measuring 48 feet. CDI, throw rope adjusted to 50 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed 6 inches between verticals in spots. Original fence. Pool built before 2010 .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - 42” high in certain areas. Pre 2010 construction.

View this inspection on the county portal ›

Apr 30, 2024 0 demerits · 0 violations
Inspector comments: Original fence still installed. Inspection conducted with Joe Brennan.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 19, 2024 0 demerits · 0 violations
Inspector comments: Original fence - 5-1/4” wide and 42” high in certain spots. Pool built before 2010. No permit issued - need updated PDSC form for new covers for 2024 season. Inspection conducted with Joe Brennan.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 25, 2023 0 demerits · 0 violations
Inspector comments: No violations.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 28, 2022 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pool construction date 1988. Fence replacement requires in-field review and approval prior to permit issuance 2023.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
.2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. Flooring with chipping seal. Does not appear slip resistant.

View this inspection on the county portal ›

May 28, 2021 0 demerits · 0 violations
Inspector comments: No violations.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 21, 2020 2 demerits · 1 violation
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Observed mirrors in restrooms not shatterproof.

View this inspection on the county portal ›

Apr 17, 2019 0 demerits · 0 violations
Inspector comments: No violations during inspection.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 18, 2018 6 demerits · 2 violations
Inspector comments: FACILITY IS NOT PERMITTED FOR NIGHT SWIMMING DURING THIS INSPECTION. IF FACILITY WANTS NIGHT SWIMMING THEY MUST CONTACT EHS TO AMEND PERMIT. LIFEGUARD NOT REQUIRED.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Horizontals measured at 29 inches. Pool is pre-2010. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Openings between fence measured at 5 inches. Pool is pre 2010.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Some standing water on floor. Keep dry.

View this inspection on the county portal ›

May 10, 2017 6 demerits · 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Distance from handrails to pool wall is 8 inches.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence on side of fence near lake is >4 inches between pickets and less than 45 inches between horizontals. Fence/pool constructed prior to 2010.

View this inspection on the county portal ›

May 20, 2016 18 demerits · 6 violations
Inspector comments: POOL PERMIT CAN BE ISSUED.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder ~7.5 inches from pool wall. ** Maintain between 3" and 6" maximum.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope that is part of ring buoy is dry rotted. ** Ring buoy replaced while on-site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
- Fencing surrounding pool has vertical members spaced > 4" a part. - Outside approach to pool barrier reduced down to 42" in height as steps lead up to deck landing. Same problem exists at left end of fence @ outside approach on top of retaining wall. ** See .2528 Fences.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
No forced air or natural cross draft ventilation in equipment & chemical room. ** Provide one or the other.
#27 · Equipment room: filter backwash discharged through an air gap −2
Sump built above grade & backwash pipe enters sump low @ side. ** Provide air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow protection on hose bibs in restrooms & on deck. ** Install vacuum breakers on all hose bibs.

View this inspection on the county portal ›

May 15, 2015 12 demerits · 5 violations
Inspector comments: PDSC form on file does not have accurate information. Whisperflo 1 hp pump on site. PDSC form has a 1.5 hp pump. 2 Paramount SDX Retros, 3 skimmers 6HPxxx. Submit PDSC form in order for permit to be issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder handrails 7.5" from pool wall. Maintain between 3" and 6".Loose handrail at steps. Keep in good repair.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fencing surrounding pool with >4" between pickets, <45" between horizontals, footholds on fence, <4" underneath. Fencing must be in compliance with .2528. New gate installed in compliance with 2010 rules.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Light burnt out in pump room. Replace light.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line to pit. Provide air gap.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention on hose bibs in restrooms. Provide backflow prevention device on all hose bibs.

View this inspection on the county portal ›

May 9, 2014 10 demerits · 2 violations
Inspector comments: Permit for pool will be accessible at meckpools.charmeck.org with in 3-5 business days. Permit shall remain posted and visible at pool area at all times.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Facility vertical bars greater than 4 inches. Maintain spacing between verifical bars at 4 inches or less.
#22 · Premises: emergency telephone provided −6
Phone number for pool phone incorrect, and address missing the number one on provided emergency information. Operator, Ben Rhodes corrected immediately.

View this inspection on the county portal ›