Apr 30, 2024 10 demerits · 3 violations
Inspector comments: Pool has a single main drain. Safety Vacuum Release is a Vacless 10-ADJ. Pump and main drain were turned off to test and it is operational. Door between the bathrooms and clubhouse remains locked at all times. Window inside of the clubhouse is permanently locked.
Inspection completed with CPO, Pierce Sawyer
All permit compliance items corrected during inspection
CPO log records begin today
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Main entrance gate was not closing all of the way to the latch. CPO installed a new spring and gate closed and latched properly. Both gates had a 1.5 inch gap directly next to the release latch. CPO installed signs on the gates to close gap to under 1/2 inch.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Several cracks were observed in the concrete around the pool deck.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room.
.2534(6) Provide sufficient lighting in chemical storage room.
Light bulb is missing from the pump room / chemical storage room.
May 25, 2023 12 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed ring buoy in disprepair and in need of replacement. CDI buoy replaced.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed deck with cracks and in need of repair.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed men’s and women’s bathrooms in Ned of cleaning.
Apr 20, 2022 0 demerits · 0 violations
Inspector comments: no demerits taken
No violations were recorded for this inspection.
Apr 20, 2021 8 demerits · 3 violations
Inspector comments: No night swimming.
General Comment: Observed some minor cracks / damage to concrete pool deck around pool deck.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed distance from grade to bottom horizontal measuring 8 inches on fence near pump room. Pre-2010 construction.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash line.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed restroom sinks and fixtures soiled.
Apr 15, 2020 6 demerits · 2 violations
Inspector comments: NO NIGHT SWIMMING.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect
unless such Orders are rescinded or superseded by another applicable Order.”
Until further guidance from local, state and federal health authority, when Pool opens, assure furniture is set up in a way to practice
social distancining of 6 feet or greater.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
No rope for break point of shallow and deep end. CDI- Provided.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Deck had trip hazard cut in it. CPO filled gap with cement during inspection.
May 8, 2019 16 demerits · 6 violations
Inspector comments: PDSC form verified.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Keep covers/caps in good repair. Observed rubber base plug for vacuum line removed easily. A larger plug was obtained to make it secure.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs closer to pool than 6 ft. Moved to provide walkway.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. No lighting in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(j) Provide soap and soap dispenser, no glass, at each sink.
.2626(m) Keep restrooms and fixtures clean and in good repair.
Men's restroom needs soap and cleaning.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2626(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. No hose bibb available.
Apr 27, 2018 10 demerits · 3 violations
Inspector comments: VGB and PDSC information verified.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed damaged ring buoy at pool site. Corrected during inspection by pool operator replacing ring buoy.
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap for back wash discharge.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Observed no hose bibs in bathrooms.
Apr 27, 2017 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Floor of Pool needs to be cleaned.
Apr 20, 2016 8 demerits · 2 violations
Inspector comments: *Permit will not be issued until new PDSC Form has ben submitted and approved. Newly installed equalizers. Two Aquastar 8HPxxx and one Aquastar A10RCFR. Pump being used is a Pentair SuperFlo model SF-N1-2A.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Skimmer baskets need emptied. Corrected during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
There are a few cracks on decking larger than 1/2".
Apr 24, 2015 2 demerits · 1 violation
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Observed broken rope bouy. COrrected onsite.
Apr 21, 2014 6 demerits · 2 violations
Inspector comments: 17. Deck has numerous cracks.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Depth and no diving markings on shallow end need to be repainted. Corrected during inspection.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Restrooms are currently locked.