WOODLAND PARK APARTMENTS

2205 KILBORNE DRIVE, Charlotte, NC 28205
Seasonal Swimming Pool · NC permit/State ID 2060500509
Latest result6 demerits
Last inspectedMay 7, 2026
Inspections on record7
On record sinceJun 27, 2017

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01632 Jun 27, 2017: 24Aug 2, 2017: 32Sep 14, 2022: 0Jun 13, 2023: 6May 24, 2024: 4May 13, 2025: 10May 7, 2026: 6
Jun 27, 2017Lower is betterMay 7, 2026

Inspections & violations

May 7, 2026 6 demerits · 2 violations
Inspector comments: Facility needs to order an extra basket for the pump room. NO NIGHT SWIMMING PERMITTED.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed multiple debris in baskets. Needs to be cleaned.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water leaks in the pump room. Needs to be fixed.

View this inspection on the county portal ›

May 13, 2025 10 demerits · 2 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope length at 35 feet. Corrected during inspection to required 45 feet (CPO supplied a new rope to ring buoy that was measured by EHS and cut to required 45 feet).
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter not operating. CPO was able to get flow meter to be functional during time of inspection.

View this inspection on the county portal ›

May 24, 2024 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed minimal debris on pool floor.

View this inspection on the county portal ›

Jun 13, 2023 6 demerits · 2 violations
Inspector comments: STICKER DELIVERED-- PAPER PERMIT AVAILABLE AT MECKPOOLS
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
REPAIR GATE SO DOWNROD IS SECURED -- RETURN VISIT IN 1 WEEK
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
REPAIR SINK IN MENS ROOM AND SUPPLY TOILET PAPER

View this inspection on the county portal ›

Sep 14, 2022 0 demerits · 0 violations
Inspector comments: Pool corrected all the previous issues. No night swimming permit.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Aug 2, 2017 32 demerits · 9 violations
Inspector comments: No pool chemical records were available during inspection, but pool has not been open due to suspension all season. Pool operator must now keep daily records of all pool chemicals.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Pool paint is in slight disrepair in some areas and will need to be repainted in the coming off season.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed a missing weir on one out of three skimmers. Replace skimmer weirs as they break/are removed.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
No diving marker had been painted over while pool was suspended. No Diving marker was re-painted between the 3 and 4 foot marker next ot the pool steps.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed exit step handrail with slight give, will need to be retightened. Ensure that handrails and ladders are kept tightly secured.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate not closing. Out of every 20 opening, latch mechanism would fail at least once to properly latch. Adjustment of the gate spring and of the latching mechanism by operator, EHS tested gate multiple times after adjustment and observed no issues. Ensure that the gate is kept in a working, self closing/latching condition
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed random assortment of construction material within 6 feet of the deck. Items were moved by operators during inspection.
#22 · Premises: emergency telephone provided −6
Phone number for the emergency phone was not posted at time of inspection, was written and posted by operator during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no ventilation in the pump room/chemical room. Provide a fan or other means of ventilation.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Shower sign was not posted before inspection began, was posted by operator during inspection.

View this inspection on the county portal ›

Jun 27, 2017 24 demerits · 6 violations
Inspector comments: 17- Observed slight deck damage on the back left side of the pool. Concrete has begun to chip. 25- Observed no ventilation in the chemical room 7- Observed a missing tile on the pool wall. Replace as soon as possible.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Facility has changed main drain covers from Aquastar A10CFRxxx to Hayward WG1048e covers. Pump max flow does not exceed the main drain specifications. Facility has three days to acquire an approved and updated PDSC form from MCHD or facility permit my be subject to suspension.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed no weirs present. Permit will be placed under an intent to suspend, facility has 30 days to replace the pool weirs or permit will be suspended.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Faciltiy lacks a safety rope on the shallow-deep drop off. Rope must be provided with proper floatation devices.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed the gate leading to the pool unsecure. It is possible to push the gate open by lifting a small bar at the bottom of the pool
#22 · Premises: emergency telephone provided −6
Emergency telephone not functioning at time of inspection. Operator was able to repair phone during visit. Function was verified by EHS.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line pipe observed to not have an airgap, as it is placed directly into the outflow pipe.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WOODLAND PARK APARTMENTS” or State ID 2060500509). Inspection type (routine vs. follow-up) is not published in the county's data.