12demerits
SOUTHPOINT CONDOMINIUMS
960 SOUTHWEST DR, Davidson, NC 28036
Seasonal Swimming Pool · NC permit/State ID 2060500514
Latest result12 demerits
Last inspectedApr 24, 2026
Inspections on record13
On record sinceApr 17, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 17, 2014Lower is betterApr 24, 2026
Inspections & violations
Apr 24, 2026 12 demerits · 3 violations
Inspector comments: NO NIGHT SWIMMING.
PERMIT RESTRICTION - PUMP MUST REMAIN AT 2650 RPM DUE TO TURNOVER. FLOW METER MUST REMAIN OPERABLE NOT TO EXCEED 80 GPM DUE TO RETURN RESTRICTION.
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
Observed plug missing in skimmer with disabled equalizer covers. CDI- plugged by CPO
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed debris in skimmers. CDI
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap.
No discharge with air gap.
Apr 23, 2025 6 demerits · 1 violation
Inspector comments: No night swimming.
Permit restriction - pump must remain at 2650rpm due to turnover. Flow meter must remain operable not to exceed 80gpm due to return restriction. EQ line plastered on wall and plugged in skimmer basket.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Observed 33’ rope for ring buoy. CDI: CPO provided new rope and cut to 36’.
Apr 17, 2024 10 demerits · 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed high pH of 8.2. CDI: CPO lowered pH to 7.8
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets. CDI: CPO emptied baskets.
Apr 25, 2023 14 demerits · 4 violations
Inspector comments: 24. confirmed pump running at 2650 rpm (linked to app on CPO phone); confirmed that flow meter is operational and reading 70 gpm.
27. cartridge filter - not designed to be backwashed
29. there are no restrooms available
#3 · Water quality: pool water pH −6
pH corrected to 7.4 during inspection
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
blocked area under fence that was > 4" during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
natural cross or continuous forced ventilation required in equipment room
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
backflow preventer required on hose bib
May 13, 2022 16 demerits · 4 violations
Inspector comments: In reference to the previous visit, EHS confirmed the following during inspection.
1. EHS confirmed pump as- Jandy VSSHP270DV2A, 2.70 thp pump
2. EHS confirmed there are (2) 2” skimmer lines; (1) 2” main drain; (2) 2” return
3. EHS confirmed the Filter – Jandy CL580
4. Facility has an extra cartridge filter for listed filter above.
5. EHS confirmed there are (3) skimmers.
6. EHS confirmed there are (2) Aquastar A10RCFRxxx drain covers.
7. EHS confirmed there is a new chlorinator – Pentair 300 model.
8. A spare pump basket for pump has been provided.
9. Change in CPO from permit submittal. Barry Michael is the current CPO.
In reference to permit denial on 5/4, the following has been confirmed during inspection.
1. Blue white flow meter installed on 2” return pipe
2. EHS measured pipe before and after flow meter. 16” before, 8” after flow meter.
3. EHS confirmed that flow meter was reading at 80gpm during inspection.
4. EHS confirmed that pump has been set at 2650RPM (through mobile app).
Note: this pool has a permit restriction for the pump to be set at 2650 RPM with a flow rating no greater than 80GPM (+/- 10%) due to floor return # restriction.
EHS confirmed PDSC information. Operator Barry Michael on site during inspection. Permit issued.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.2 to start inspection. CDI- CPO corrected pH, EHS tested at 7.6 after correction.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed flower debris in one skimmer during inspection. CDI- skimmer cleared.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Pool constructed in 1988. Observed foothold at 37” around the entrance of the pool.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.Observed no backflow preventer on hose bib.
Apr 26, 2021 6 demerits · 2 violations
Inspector comments: Kara Gilchrist present during the inspection. Verified pumps and main drains. Equalizers are plugged per state regulations.
Seasonal permit issued.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Horizontals shall not be located less than 45" in height. Pool constructed in 1988. Observed foothold at 37” around the entrance of the pool Gazebo.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.Observed no backflow preventer on hose bib.
May 12, 2020 6 demerits · 1 violation
Inspector comments: 25. .2533(b) Provide sufficient lighting in pump room.
Observed lighting inoperable inside of pump room. Lighting needs to be replaced.
*No signature required due to COVID-19*
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Rope is supposed to be 36ft according to pool information, rope was longer. Rope was cut to appropriate length.
Apr 12, 2019 8 demerits · 3 violations
Inspector comments: CPO Kara Gilchrist was present during the inspection.
Night Swimming is not permitted.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.- Observed skimmers full of debris. CDI- PIC removed all debris.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Observed no forced ventilation and no cross ventilation in chemical/pump room.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
(.2512) - Provide back flow prevention. - Observed no back flow prevention device on the hose bib located on the pool deck.
May 4, 2018 12 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Cleaned out skimmers during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Pool constructed in 1988; first horizontal to second horizontal on fence is less than 45 ".
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction; lounge chairs within 6 ft of school. Corrected during inspection.
Apr 28, 2017 4 demerits · 1 violation
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed greater than 25 ft between depth markings. CDI water level drained tile added to required areas. No follow up required.
*****PROVIDE UPDATED PDSC FORM TO INDICATE NEW DRAIN COVERS AND COVERED EQUALIZER LINES. PDSC FORM MUST BE APPROVED BEFORE PERMIT WILL BE ISSUED****
May 6, 2016 6 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Fence is less than 48 inches high. Measured at 45 inches in most areas. Mesh screen was put over both gates.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no cross ventilation in pump/chemical room, and no continuous fan. Bags of chemicals on floor.
Apr 23, 2015 22 demerits · 6 violations
#3 · Water quality: pool water pH −6
Observed pool water pH of 7.1. CDI to 7.2
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed missing 4ft tile marker on pool wall. CDI
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder with missing end cap bumper.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed gate latch height of 53". CDI to 54"Observed openings in fence > 4"
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed pool deck chairs < 5' from ladder rail. CDI
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed no cross ventilation in pump room, and no fan.
Apr 17, 2014 14 demerits · 3 violations
Inspector comments: Called and spoke with Katie about the EQ cover- They are on the exemption list because of the location of the equalizer line cover.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
observed debris on pool floor
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
rope length too long - corrected during inspection
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
observed several cracks on pool decking.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SOUTHPOINT CONDOMINIUMS” or State ID 2060500514). Inspection type (routine vs. follow-up) is not published in the county's data.