‹ Back to search

2demerits

SPINNAKER COVE

405 WINDWARD DRIVE, Davidson, NC 28036
Seasonal Swimming Pool · NC permit/State ID 2060500517
Latest result2 demerits
Last inspectedApr 30, 2026
Inspections on record13
On record sinceApr 22, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0816 Apr 22, 2014: 4Apr 6, 2015: 6Apr 15, 2016: 6Apr 5, 2017: 12Apr 17, 2018: 16Apr 10, 2019: 8Apr 23, 2020: 4May 7, 2021: 10May 2, 2022: 0May 26, 2023: 12May 1, 2024: 0Apr 29, 2025: 2Apr 30, 2026: 2
Apr 22, 2014Lower is betterApr 30, 2026

Inspections & violations

Apr 30, 2026 2 demerits · 1 violation
Inspector comments: NO NIGHT SWIMMING Permit Restriction: Flow meter shall remain operable. Flow required at 54 gpm to 63 gpm to meet turnover and flow restriction of the filter. Flow greater than 119 gpm exceeds drain covers. Suction Hazard.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed discharge pipe in the drain basin.

View this inspection on the county portal ›

Apr 29, 2025 2 demerits · 1 violation
Inspector comments: General comment: Flow for pump was at 70 GPM. Operator lowered the GPM to 62. Permit restriction written on permit
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed chemical bags stored on the floor.

View this inspection on the county portal ›

May 1, 2024 0 demerits · 0 violations

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 26, 2023 12 demerits · 4 violations
Inspector comments: Field confirmed: 1. new pump - Pentair Intelleflow3VSF, 011075 2. Blue White flow meter on 2" pipe with 12" pipe into flow meter and 10" of pipe out of flow meter 3. Main drain, skimmer, and return line on 2" pipe 4. (2) Aquastar VGB2008 A10RCFRxxx drain covers 5. (4) Aquastar VGB2008 A8Rxxx EQ line covers 6. (1) Pentair TR-60 filter 7. 4 returns 8. 4 skimmers 9. pump flow set at 60 gpm and read at 60 gpm
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Rope corrected to 48' during inspection
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
mirror to be of shatterproof construction
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
fill spout not to extend > 2" beyond pool edge

View this inspection on the county portal ›

May 2, 2022 0 demerits · 0 violations
Inspector comments: NO VIOLATIONS NOTED.

No violations were recorded for this inspection.

View this inspection on the county portal ›

May 7, 2021 10 demerits · 3 violations
Inspector comments: Night swimming is NOT permitted.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone did not ring when EHS called back the number. CDI: operator changed phones. EHS called back number and emergency phone is now working properly. Corrected during inspection.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed labels on piping and valves had worn off. Relabel to ensure labels are clear and legible.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(k) Provide shatterproof mirrors. Mirrors not shatterproof in restrooms.

View this inspection on the county portal ›

Apr 23, 2020 4 demerits · 2 violations
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. - Bagged chemicals stored directly on the floor.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. - Observed no air gap in pump room. Benji Sheehan of Swim Club Management was present.

View this inspection on the county portal ›

Apr 10, 2019 8 demerits · 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Right side entry gate is sticking on concrete walkway when opened and therefore not self closing. Band clamps were added during inspection and magna latch locked. It must remain locked and bande3d unless it is fixed and able to self close without sticking. Gate on backside of pool has also been band clamped. The lock on the gate was unable to be unlocked.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some chairs too close to pool edge. Maintain six feet of clearance around pool edge.

View this inspection on the county portal ›

Apr 17, 2018 16 demerits · 4 violations
#3 · Water quality: pool water pH −6
pH reading below 7.2 at start of inspection. pH corrected during inspection
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Install a protective bumper on the ladder.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Keep furniture >6' from the pool edge.

View this inspection on the county portal ›

Apr 5, 2017 12 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
observed floating debris in the surface skimmers. Cleared all floating debris in the surafce skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrail loose. Tightened during inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck obstruction. Lounge chairs within 6' of pool edge.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on floor in pump room. Observed Aquasalt bags on floor in equipment room. Advised to keep equipment room clean, dry, and keep chemical bags off of the floor.

View this inspection on the county portal ›

Apr 15, 2016 6 demerits · 1 violation
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed no cap on vacuum port. CDI-cap provided and put in place.Equalizer covers and pump model on site do not match PDSC form records on file supplied by Pool Management company. Permit cannot be issued until form with correct equalizer covers and pump model is submitted and approved by MCHD.

View this inspection on the county portal ›

Apr 6, 2015 6 demerits · 2 violations
Inspector comments: NOTE: Permit will be posted online within 3 days at meckpools.charmeck.org.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Tighten loose handrail. (Tightened during inspection)
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Maintain 6 ft deck clearance around pool deck. Observed some lawn chairs and one round table < 6ft from edge of deck. (Moved during inspection).

View this inspection on the county portal ›

Apr 22, 2014 4 demerits · 1 violation
Inspector comments: Very nice job!
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmer baskets.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “SPINNAKER COVE” or State ID 2060500517). Inspection type (routine vs. follow-up) is not published in the county's data.