4demerits
THURINGER COURT
2771 VON THURINGER COURT, Charlotte, NC 28210
Seasonal Swimming Pool · NC permit/State ID 2060500550
Latest result4 demerits
Last inspectedApr 9, 2026
Inspections on record14
On record sinceJun 9, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 9, 2014Lower is betterApr 9, 2026
Inspections & violations
Apr 9, 2026 4 demerits · 1 violation
Inspector comments: Permit Restrictions- Flow meter operable. Flow range at 85 to 105 pm to meet turnover and flow restriction of return pipe size. Eq lines plugged.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). EHS observed areas where the gap between the bottom of fencing and ground level exceeded 4” due to erosion. CDI - CPO added additional pine straw and the gap was reduced to less than 4”.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". EHS observed vertical bars with distance greater than 4”. Pool was built pre May 2010.
Apr 9, 2026 0 demerits · 0 violations
Inspector comments: This form is to serve as a correction to the previous inspection conducted. On the previous inspection the status code was incorrectly entered as “Q” status when the pool should have been entered as “A” status. EHS has filled out this inspection form to correct that notation. The pool passed inspection and shall be placed on A status. (See previous inspection sheet to observe violations documented).
Permit Restrictions- Flow meter operable. Flow range at 85 to 105 pm to meet turnover and flow restriction of return pipe size. Eq lines Plugged.
No violations were recorded for this inspection.
Apr 9, 2025 2 demerits · 1 violation
Inspector comments: No night swimming.
Permit Restrictions- Flow meter operable. Flow range at 85 to 105 pm to meet turnover and flow restriction of return pipe size. Eq lines plugged.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap on filter backwash.
Apr 12, 2024 12 demerits · 4 violations
Inspector comments: Observed pump running at 3110 RPM prior to backwash, raising pressure to 100 gpm. When set to 2350 rpm per permit conditions, flow meter read 70 gpm.
Observed potential foot hold at rear fence (conduit box) and vertical posts at approximately 5 inches in separation at metallic fencing.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2514(c) Pool finish shall be white or light colored. Observed minor discoloration of pool wall, floor, and tiles. Resurface pools as needed
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pump running at 3110RPM, pump is only allowed to run at 2350RPM. PO adjusted and the pump was running at 2350 by the end of inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap on filter backwash.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed men’s restroom urinal non flushing.
Apr 13, 2023 4 demerits · 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed pump running at 3110RPM, pump is only allowed to run at 2350RPM. PO adjusted and the pump was running at 2350 by the end of inspection.
Apr 21, 2022 18 demerits · 5 violations
Inspector comments: Pool not permitted for night swimming.
PDSC verified.
Pump verified Pentair Intellliflo vsf 011056
Blue White Flow meter observed.
Observed 3 skimmers w/ 0 operable.
EQ lines were observed plugged at wall.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed top step on the ladder with screw missing causing the ladder’s step to only hold weight on one side. CDI- Screw was replaced during inspection by CPO.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed damaged ring buoy and rope. CDI- Both ring buoy and rope were placed during the inspection. Rope was cut to a length of 36 feet.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Distance from ground to bottom horizontal bar is as much as 8 inches in some areas and consistently greater than 4 inches around entire pool premiere. Pool built prior to 2010
Distance between horizontals on fence measured up to 5 1/2 inches. Pool built pre 2010.
#21 · Premises: pool and deck lighting provided at pools that operate at night −4
.2524(c) Lighting fixtures shall not present a hazard to the public. Observed light casing inside of the pool hanging with a protruding screw attached. Replaced during inspection by CPO to secure lighting fixture.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap.
Apr 29, 2021 20 demerits · 6 violations
Inspector comments: General comment - observed minor plaster cracking/flaking on pool floor in deep end. Due to expected deterioration over season, pool plaster may need to be evaluated for significant repair prior to permitting 2022 season.
Pool not approved for night swimming.
Intent to suspend issued for replacement of missing skimmer weir.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Debris present on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Missing weir on skimmer basket near stairs. Intent to suspend issued.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Flat head bolt/screw protruding from side of ladder. PIC repaired.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Distance from ground to bottom horizontal bar is as much as 8 inches in some areas and consistently greater than 4 inches around entire pool premiere. Pool built prior to 2010
Distance between horizontals on fence measured up to 5 1/2 inches. Pool built pre 2010.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Pool chairs within 3 feet of pool edge. Chairs pushed away from pool.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap.
Apr 16, 2020 10 demerits · 3 violations
Inspector comments: NIGHT SWIMMING NOT PERMITTED.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect
unless such Orders are rescinded or superseded by another applicable Order.”
Until further guidance from local, state and federal health authority, when Pool opens, assure furniture is set up in a way to practice
social distancining of 6 feet or greater.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Distance from ground to bottom horizontal bar is 5 inches on fence. Pool built prior to 2010
Distance between horizontals on fence measured at 5 inches. Pool built pre 2010.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some protrusions on deck, creating a trip hazard. CDI- Dry putty inserted in crevices.
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap for backwash piping.
Apr 11, 2019 20 demerits · 6 violations
Inspector comments: NO POINTS WERE TAKEN FOR THE FOLLOWING:
PDSC information verified. No night swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed cleaning needed on pool floor. Main drains still visible.
.2537(14) Keep pool surface and pool floor free of debris.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Repeat Observed gaps measuring 6 inches in several areas under fence. Observed fence to measure 45.5 inches in several areas. Observed lattice fence squares to measure 2.75 inches. Observed spaces between fence rung to be 5.5 inches.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Mesh shall not exceed 2.25" square.
#22 · Premises: emergency telephone provided −6
Repeat Observed two phone numbers listed on emergency phone instructions. CDI: Incorrect phone number taped over.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Repeat Observed hose bib without backflow prevention on pool deck. Hose is corroded onto hose bib and would not come off. CDI: Backflow prevention device placed on the end of hose. Observed pump room floor to be wet.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
#27 · Equipment room: filter backwash discharged through an air gap −2
Repeat Observed backwash pipes to be connected without an air-gap. Cut end of pipe to create air gap.
.2513(b) Filter backwash shall be discharged through an air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Repeat Observed shower to not have handles or be operable.
.2626(h) Shower(s) shall be provided.
Apr 12, 2018 18 demerits · 6 violations
Inspector comments: Observed some cracking on pool deck. Maintain in good condition.
Observed some debris starting to accumulate in pool. Ensure pool is maintained clean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed clearance up to 7 3/4" below lattice fence line and lattice fence squares are 2 3/4" x 2 3/4". Observed clearance under wrought iron fencing at 6 1/4" and space between vertical mem['p;/mbers of wrought iron fencing up to 5 1/2".
#22 · Premises: emergency telephone provided −6
An incorrect phone number listed on emergency pool phone. CDI, pool operator crossed out old phone number with marker and only the proper number is showing.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Observed light not working in pump room.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed mechanical ventilation not working.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed no back flow provided at hose bib near pump room.
.2533(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed pool chemical bag stored on ground.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2626(h) Shower(s) shall be provided. Shower not operable during visit.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(j) Provide soap and soap dispenser, no glass, at each sink. Observed no soap available in restrooms.
May 11, 2017 20 demerits · 7 violations
Inspector comments: -- #6 Pool has 3 skimmers. EHS observed that each equalizer line has been plugged inside the skimmer and on the pool wall. Plugs appear to require tools to remove. CPO (J. Mullis) stated that she was informed that the equalizer lines were drained & plugs were installed on 5/8/17 and that a new PDSC form has been or is going to be submitted to the MCHD.
GC -- #6 Current PDSC form indicates that the pool pump is a Sta-Rite model # P4R6G3 w/ HP 2. PDSC form verified to be incorrect in field. EHS observed an old Sta-Rite Maxi-E-Glas pump w/ an Emerson 2 HP replacement motor. No identifying information is present on the pool pump and it may not be a model currently listed in the EHS pump field guide. EHS suspects from review of old circa 1987 Sta-Rite Max-E-Glas literature that the pump may be model PE5GL/ HP 2; however, no pump flow chart found. ** Trident Pool Group is responsible for the positive identification of the pump and providing its maximum pump flow. A new PDSC form must be submitted to the MCHD & the form must be approved by K. Wilson prior to the pool permit being issued.
GC -- #15 Pool field book indicates pool throw rope length of 24'. Pool has an irregular "kidney" shape. With the assistance of CPO, maximum pool width determined to be ~24' . ** Throw rope shall be 1.5 times max. width of pool or 50' , which ever is less. EHS re-established throw rope length to 36' and 36' new throw installed on ring buoy while EHS on-site.
GC -- #21 CPO reports pool lighting insufficient for night swimming and pool hours are from dawn to dusk. No pool hours posted. CPO wrote pool hours of dawn to dusk on standard pool rules sign posted inside pool enclosure while EHS on-site. Standard pool rules sign is visible from pool entrance gate. Pool entrance gate can only be opened via key inserted into gate handle and CPO states residents are issued a key to the pool gate. ** EHS recommends relocating standard pool rules sign to front gate or posting an additional pool sign with hours of operation dusk to dawn in large bold print on front gate. EHS further recommends that gate be secured with a chain w/ lock (or by some other means) when pool is not open to prevent access.
POOL PERMIT CANNOT BE ISSUED UNTIL A NEW PDSC FORM IS SUBMITTED TO THE MCHD AND THE FORM IS APPROVED BY K. WILSON.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Pool has 3 skimmers. One weir is stuck & therefore, will not float freely/ function properly. ** CPO replaced this weir while EHS on-site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed clearance up to 7 3/4" below lattice fence line and lattice fence squares are 2 3/4" x 2 3/4" (providing footholds). Observed clearance under wrought iron fencing up to 6" and space between vertical members of wrought iron fencing up to 5 3/4".
** See .2528 Fences. Clearance beneath all fencing shall be no greater than 4". Space between vertical wrought iron fence members shall be no greater than 4". Lattice fence openings (squares) shall be no greater than 2.25 inch square/ lattice fence compared to requirements of chain link fencing mesh size restrictions.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed chips of concrete missing or loose on pool deck creating > 1/2" offsets. (Note: same deck condition documented in B. Hallman's 2016 inspection of pool & B. Hallman specified that this be resolved before 2017 pool season.) ** CPO obtained cement & deck was repaired/ patched where needed while EHS on-site
-- Observed pieces of concrete missing in 2 areas of pool coping (of which one area warrants repair prior to pool being opened for season). ** Maintain coping in good repair. CPO patched the one badly chipped area of coping while EHS on-site.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Both forced air vents in equipment/chemical room inoperable. ** Maintain forced air ventilation in proper operating order. Repair.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash pipe inserted down into larger pipe in floor.
** Back wash water should discharge through a complete air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
-- Urinal runs continuously & does not "flush". Urinal is dirty. ** Repair urinal & clean it. Keep all fixtures clean.
-- No soap provided at lavatories in restrooms. ** Provide.
-- Observed hot water @ ~118.5F at lavatories in restrooms. ** Maximum hot water temperature allowed is 110F.
-- One light fixture in women's restroom is not working properly/ light bulbs are not illuminating correctly.
** Resolve.
-- Mirrors in restrooms do not appear to be shatterproof.
** See .2526(k)
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Hose bib located just outside equipment/ chemical room and the hose bibs located inside the equipment/ chemical room have no back flow protection. ** Install vacuum breaker on each hose bib.
Apr 28, 2016 12 demerits · 4 violations
Inspector comments: General Comment: PDSC form needs to be updated. Corrected pump info in the field. Model # P4RGG3 Sta-Rite Dura Glass.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Verticle/Horizontal rails are greater then 4" (5"). Pool constructioin date is 1984.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Areas on deck are greater than 1/4" where concrete was chipping. Grout/ Repair prior to 2017 season.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Ensure that forced air ventilation is functioning properly.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
Provide vaccum breakers on all hose bibbs.
May 13, 2015 20 demerits · 7 violations
Inspector comments: POOL PERMIT CAN BE ISSUED.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some soil/ scum on pool wall tiles ** Clean.
Concrete chipped out in places above wall tiles.
** Repair.
Pool floor has small chipped spots throughout.
** Repaint.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Up to 7 3/4" below lattice fence line. Lattice squares
2 3/4" x 2 3/4". Wrought iron (fence) verticals spaced up to 5 3/4". ~5 1/2" below wrought iron fence.
** See .2528 (a) & (b).
#18 · Premises: lifeguards present or warning signs posted −4
Warning sign "CHILDREN SHOULD NOT...", "ADULTS SHOULD..." has upper & lower case letters. Lower case letters <1" in height. ** Corrected during inspection. Standard pool rules sign posted.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Forced air vents in equipment/ chemical room inoperable. ** Repair.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line inserted down into larger pipe.
** Backwash water should discharge through a complete air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors not shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No backflow prevention on house bib outside equipment/ chemical room. ** Install vacuum breaker.
Jun 9, 2014 14 demerits · 4 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed dry rotted ring buoy--CDI replaced
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed wood fence with lattice greater than 2.25 inches. More than 4 inches between ground and bottom of fence. Fence has greater than 4 inches between vertical members. Fence slightly less than 48 inches from exterior.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed no backflow preventers on threaded faucets.**Depth markers fading will need to be repainted.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “THURINGER COURT” or State ID 2060500550). Inspection type (routine vs. follow-up) is not published in the county's data.