4demerits
TRIANON CONDOMINIUMS
3512 COLONY RD, Charlotte, NC 28211
Seasonal Swimming Pool · NC permit/State ID 2060500558
Latest result4 demerits
Last inspectedApr 20, 2026
Inspections on record16
On record sinceApr 22, 2014
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Apr 22, 2014Lower is betterApr 20, 2026
Inspections & violations
Apr 20, 2026 4 demerits · 1 violation
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface and pool floor. Clean as needed.
Apr 15, 2026 20 demerits · 4 violations
#2 · Water quality: disinfectant residual provided by −6
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public.Observed off-white bubbles and foam, strong odor of chlorine, and granuals at bottom of weir basket. Pool inspection fails, placed on Q status.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface and pool floor. Clean as needed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed doors leading onto the pool deck from clubhouse not self latching, door alarms which were placed last inspection were disabled. CPO turned on door alarms. Door alarms MUST remain operable since doors are not self latching REPEAT
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone able to call 911 and verify phone number and address. When EHS called phone back it did not ring and the call could not be completed. CDI, PIC replaced phone and retried, phone was able to be called back and had audible ring.
Apr 9, 2025 8 demerits · 2 violations
Inspector comments: No Night Swimming.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool surface and pool floor. Clean as needed.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed doors leading onto the pool deck from clubhouse not self latching, door alarms which were placed last inspection were disabled. CPO turned on door alarms. Door alarms MUST remain operable since doors are not self latching REPEAT
May 23, 2024 10 demerits · 2 violations
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.4ppm. CPO corrected chlorine to 1ppm during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed doors leading onto the pool deck from clubhouse not self latching, door alarms which were placed last inspection were disabled. CPO turned on door alarms. Door alarms MUST remain operable since doors are not self latching
May 17, 2024 10 demerits · 2 violations
Inspector comments: Re-inspection fee required. Call the main office at 980-314-1620
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed doors leading onto pool deck from clubhouse not self latching. CPO attached audible alarms to both doors during inspection.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone able to call 911 and verify phone number and address. When EHS called phone back it did not ring and the call could not be completed.
May 2, 2024 22 demerits · 4 violations
Inspector comments: Re-inspection fee required. Contact Main office at 980-314-1620.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0ppm at beginning of inspection. CPO was able to correct chlorine to 2.5ppm by end of inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope longer than 38ft. CPO cut rope to required length during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed both doors entering pool deck from clubhouse are not self latching.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone was able to connect to 911. However when EHS called phone back it did not ring.
Jun 29, 2023 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris present inside of 1/2 of the skimmers present. Empty as needed.
Apr 12, 2022 16 demerits · 5 violations
Inspector comments: Night swimming has not been approved.
PDSC verified.
Recommend setting up pool phone showing as Trianon Condominiums Pool Phone instead of just Trianon Condominiums.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed pollen buildup and debris in the pool. The main drains and floor were still visible. Have cleaned.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed debris buildup to the skimmer baskets. This was corrected by having the baskets properly cleaned.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Observed ladder at 6.5” measured from wall.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Chlorinator observed in need of flow indicating device to be NSF compliant.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. Observed hose bibs without back-flow prevention device present at pool shower and another location.
Apr 26, 2021 8 demerits · 2 violations
Inspector comments: PDSC verified.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy was too long. It was cut to proper length.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water around pump room. May be a leak in the piping. Repair.
Apr 8, 2020 10 demerits · 3 violations
Inspector comments: Night swimming has not been approved.
*Decks are in good repair but are beginning to chip and crack. Might need repair prior to opening for next season.
Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
The skimmers will be expiring in October of 2020. A new PDSC Form must be submitted and approved with the updated information.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed pollen buildup and debris in the pool. The main drains and floor were still visible. Have cleaned.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Observed debris buildup to the skimmer baskets. This was corrected by having the baskets properly cleaned.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Observed chemicals with a paper casing that were stored on the ground. This is corrected by having the bags placed onto pallets.
Apr 12, 2019 14 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed initial ph at 8.0. After adjustments ph dropped to 7.8
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool debris on pool floor.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers in need of cleaning.
Apr 20, 2018 10 demerits · 3 violations
Inspector comments: PDSC form verified by J Perry. Model # is not available on the pump. It appears the same as the picture in pool book. Motor is a 2.6HP.
Install backflow preventer on hose bibb at shower outside.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris.
Observed debris on the pool floor.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2519(k) Provide operational pressure gauge on filter. Observed pressure gauge non-functional. Replaced during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2626(i) Water in restrooms shall not exceed 110 F.
Men's water temped at 126F. Women's water temped at 113F.
Mar 31, 2017 8 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed skimmer baskets with debris inside. Pool operator cleaned out skimmers. Corrected during the inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose ladder. Operator tightened during the inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed floor to be holding water near filter and pump. EHS could not identify source of water.
General Comment: 22: EHS experienced emergency phone issue during call to emergency response call center. Pool operator switched phones in which allowed for EHS to properly contact emergency responders.
Apr 29, 2016 10 demerits · 3 violations
#13 · Pool maintenance: contrasting band on steps and benches −4
Color band tiles more than 1 inch from edge in many areas. Need to paint or fix before permitted next year.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed one gate not closing/latching. Corrected onsite with cahin and padlock.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Obs.erved open bag of sodium bicarb on floor. moved to shelf.
Apr 27, 2015 8 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence not secured in several areas. Secure.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Observed water in bathrooms hotter than 110F. Backflow preventers missing on threaded faucets.
Apr 22, 2014 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Cracks on pool surface.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Leak in pump room where chemicals stored.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “TRIANON CONDOMINIUMS” or State ID 2060500558). Inspection type (routine vs. follow-up) is not published in the county's data.