Latest result0 demerits
Last inspectedApr 15, 2026
Inspections on record13
On record sinceMay 8, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01836 May 8, 2014: 0Apr 23, 2015: 6May 4, 2016: 10May 1, 2017: 6May 9, 2018: 14May 10, 2019: 8Apr 8, 2020: 4May 7, 2021: 18May 25, 2022: 6May 10, 2023: 36May 3, 2024: 8Apr 24, 2025: 24Apr 15, 2026: 0
May 8, 2014Lower is betterApr 15, 2026

Inspections & violations

Apr 15, 2026 0 demerits · 0 violations
Inspector comments: POOL IS OPEN FOR 2026 SEASON. NO NIGHT SWIMMING. CONTRASTING BANDS WERE STILL VISIBLE FOR 2026 SEASON. MAY NEED TO BE REPAINTED FOR 2027.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Apr 24, 2025 24 demerits · 7 violations
Inspector comments: Inspection with CPO, Nalkus Mincer No night swimming Built without equalizers. 2” contrasting bands color band on steps may need to be repainted prior to issuance of 2026 operating permit Steps in need of repainting during next pool drainage
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed pool with moderate leaf and pollen debris on the pool surface and floor.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2523(e) Maintain breakpoint rope and floats in good repair. Observed minor fraying of breakpoint rope.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521 Install ladders per manufacturer instructions. Observed left hand rail of ladder that was not fixed into place and could be pulled out. CDI-CPO screwed down handrail and is in place.
#13 · Pool maintenance: contrasting band on steps and benches −4
.2521(b) Provide at least 2" contrasting color band to edge of stair treads. Observed minor discoloration of contrasting bands on pool steps. Steps to be repainted next time pool is drained.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed heavy fraying of ring buoy rope and rope that was not 36” in length per pool width. CDI-CPO replaced ring buoy and cut rope length to 36”.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed sign that said no children should use the pool without supervision in 3/4” lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed sign that did not have adults should not swim alone written. CDI-CPO changed out sign with correct verbiage in 1” lettering.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. Observed no lights in pump room. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed waterproof container of chemicals stored outside upon arrival. CPO stated that chemicals are stored in complex storage room and need maintenance access.

View this inspection on the county portal ›

May 3, 2024 8 demerits · 2 violations
Inspector comments: Observed some fading on contrasting color band but still measures 2” to edge of step. Areas where less than 2” corrected during the inspection. Band on steps required to be repainted prior to 2025 operating permit.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed some debris inside the pool and on pool floor. Pool was clear enough to see main drains.
#13 · Pool maintenance: contrasting band on steps and benches −4
.2521(b) Contrasting color band shall be clearly visible./ .2521(b) Provide at least 2" contrasting color band to edge of stair treads. Observed some fading on contrasting color band but still measures 2” to edge of step. -CDI- CPO corrected areas where less than 2”. **Band on steps required to be repainted prior to 2025 operating permit**

View this inspection on the county portal ›

May 10, 2023 36 demerits · 8 violations
Inspector comments: Pool plans to close at 8pm. Night swimming prohibited.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine levels at 0ppm. CDI; corrected to 1ppm during inspection.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed lots of sand, leaves, and other debris inside the pool and on pool floor. Pool was cleaned enough to see main drains. CDI: cleaning was being done during inspection.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed leaves and sand in skimmers. Cleaned during inspection.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder at 8ft side loose. Tightened.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope shorter than 36’ required length. Corrected to 36 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Back gate not able to self close. Gate repaired during inspection. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). More than 4” (pre-2010 construction) under gate and fence (in back). Gate repaired to meet rules during inspection. No permit action on fencing due to pre-2010 construction.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone sign posted. CDI: sign provided with correct information during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Observed flow meter stuck. CDI: repaired during inspection.

View this inspection on the county portal ›

May 25, 2022 6 demerits · 1 violation
#4 · Water quality: water temperature of heated pool −6
Pool was 7.0 PH, PIC added chemicals and it was 7.2 by the end of inspection. *Sidenote-EHS did not verify GPM-this was enacted Monday-EHS was not aware of this new rule.

View this inspection on the county portal ›

May 7, 2021 18 demerits · 5 violations
Inspector comments: *PDSC information verified on site*
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Rungs on both ladders more than 6” from wall.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope longer than required length. Cut down to 36 ft.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Gate not able to self latch. Gate repaired during inspection. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). More than 4” (pre-2010 construction) under gate and fence (in back). Gate repaired during inspection. No permit action on fencing due to pre-2010 construction. .2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches. Cut outs on gate larger than 1.17 inches. Material placed over cut outs.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Repairs need throughout decking.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. No lighting provided in pump room.

View this inspection on the county portal ›

Apr 8, 2020 4 demerits · 1 violation
Inspector comments: Night swimming has not been permitted. The color contrasting bands are beginning to fade in the pool. Have repainted for next year. Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris buildup in the pool. The main drains and the floors were easily visible. Have cleaned.

View this inspection on the county portal ›

May 10, 2019 8 demerits · 2 violations
Inspector comments: Contrasting color bands around the edge of the pool and at the breakpoint for depth change in need of repainting.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed floating debris on pool surface
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers in need of cleaning.

View this inspection on the county portal ›

May 9, 2018 14 demerits · 6 violations
Inspector comments: PDSC form verified. For next season: repaint transition point on pool floor and leading edge of steps.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Rail leading into the shallow area steps was not secure. Secured during inspection.
#18 · Premises: lifeguards present or warning signs posted −4
.2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Standard signage was missing. Posted a new Pool Rules sign meeting requirements during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(6) Provide sufficient lighting in chemical storage room. No lighting in chemical room/pump room. .2518(d) Piping and valves shall be labeled with color codes or labels. Pipes labeled during inspection. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. No forced ventilation or cross ventilation.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap present.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
.2526(a) Provide at least one sink and toilet for residents and guests if furthest unit is more than 300 feet from the pool at hotels, motels, condominiums and apartments. .2626(h) Shower(s) shall be provided. No restroom or shower provided.
#33 · Dressing and sanitary facilities: hose bibbs and floor drains provided −2
.2626(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. No hose bib provided.

View this inspection on the county portal ›

May 1, 2017 6 demerits · 2 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537 Keep pool floor clean; Observed pool floor in need of cleaning.
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
.2515, .2523 Safety rope with floats at depth change; Observed no rope available; CDI rope provided.

View this inspection on the county portal ›

May 4, 2016 10 demerits · 2 violations
Inspector comments: Pool needs minor cleaning on pool floor for dirt and sand build up.
#3 · Water quality: pool water pH −6
Observed pH reading 7.0. After several attempts of fixing on site pH recovered to read 7.3.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed the vertifcal clearance between the grade and the bottom barrier of the fence to be 5 inches. (Built 1975)

View this inspection on the county portal ›

Apr 23, 2015 6 demerits · 2 violations
#10 · Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints −2
Replace safety rope with floats at break point. Safety rope with floats is starting to fray!
#13 · Pool maintenance: contrasting band on steps and benches −4
Repaint contrasting color band at break point, steps and around edge of pool by next swimming pool season. Contrasting bands are still visible but observed paint chipping/missing in some area. General Comment: Continue to clean pool floor and walls. Monitor and repair cracking/chipping concrete on pool decks. Mark Houff and Austin Carithers present at time of inspection. Equalizer lines are permanently blocked.

View this inspection on the county portal ›

May 8, 2014 0 demerits · 0 violations
Inspector comments: 12 - Equalizer lines permanently plugged. Pool is old enough to not have to meet requirement.

No violations were recorded for this inspection.

View this inspection on the county portal ›