WOODLAND ESTATES

6147 WINGED ELM COURT, Charlotte, NC 28212
Seasonal Swimming Pool · NC permit/State ID 2060500569
Latest result32 demerits
Last inspectedJul 29, 2026
Inspections on record15
On record sinceJul 15, 2013

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

02244 Jul 15, 2013: 18Jul 16, 2014: 12Jun 26, 2015: 12Jun 7, 2016: 16Jun 8, 2017: 14Jun 21, 2018: 12Jun 17, 2019: 26Jul 15, 2022: 2May 23, 2023: 4Jun 27, 2024: 18Jul 31, 2024: 4May 29, 2025: 44Jun 10, 2025: 16Apr 16, 2026: 20Jul 29, 2026: 32
Jul 15, 2013Lower is betterJul 29, 2026

Inspections & violations

Jul 29, 2026 32 demerits · 9 violations
Inspector comments: Note: Glass used in fireplace. Could not verify as tempered glass. Recommend removing unless glass is tempered. Intent to Suspend issued for: .2535 - provide DPD-2 reagent; maintain daily record keeping for chlorine, pH and main drain checks; weekly record keeping for total alkalinity and cyanuric acid. A CPO shall be present at the property daily for management of the pool. .2518 - install weirs per mfg. instructions. .2528 - install window limiters at 4" or less on windows that open on to pool deck; doors from restrooms shall self-close, self-latch or self-close with audible alarm. .2537 - clean areas where water is pooling on deck - deck shall be slip-resistant. .2535 - Chlorine and acid tied into same return line to feed into the main return line back to the pool. Presents hazard. Chemicals should not be mixed to prevent hazard. Chlorinate/acid feed through an approved system. .2518 - Provide spare pump basket for the pump - Pump shall be set where combined flow of flow meters at 122 gpm to 148 gpm. Wanda Sanchez present during the inspection. Note: No paper towels in men's restroom. Provide paper towels. Note - Pump room plumbing run with (1) main drain line, (4) separate skimmer lines and (2) separate return lines. Permit Restrictions: 1) Both flow meters must remain operational. Combined flow range shall be from 122 gpm to 148 gpm to meet turnover and flow restriction of the filters. Combined flow shall not exceed 170 gpm due to drain cover flow restriction. Suction Hazard. 2) (1) of 2 doors of double doors must remain permanently affixed or both doors shall be equipped to self-close with audible alarm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
DPD-2 reagent expired. Replace expired reagent. Provide a log book for record keeping. Maintain chlorine, pH and main drain checks daily. Maintain total alkalinity and cyanuric acid readings weekly. Provide CPO certification for current CPO. Permit denied for all items.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some algae on pool walls. Continue to monitor and treat as needed. Automated feeder not operable and facility is manually feeding which may be adding to algae issue.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
One skimmer weir upside down and (2) skimmer weirs missing. Replace weirs where needed. Install skimmer weir per mfg. instructions, right-side up. Permit denial.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Windows from clubhouse that open on to pool deck (two windows on left side) without limiters. Windows shall be limited at 4" or less. Permit denial. Doors from restrooms do not self-latch. Doors shall self-close, self-latch or self-close with audible alarm. Permit denial.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Multiple areas on pool deck with pooling water. Areas appear to be slick. Eliminate pooling water and clean areas so decking is slip-resistant. Permit denial. Expansion joints with deck cracking/damage. Repair prior to 2027 operating season.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Automated feeder unplugged. No stick feeder provided. Chlorine and acid tied into same return line to feed into the main return line back to the pool. Presents hazard. Chemicals should not be mixed to prevent hazard. Chlorinate/acid feed through an approved system. Permit denial.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Pump required set to a flow where combined flow range is from 122 gpm to 148 gpm. Pump currently set and combined flows at 115 gpm. Pump shall be set to meet permit restriction. Permit denial. No spare pump basket for the pump. Provide spare pump basket for pump. Permit denial.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Shower not operable on pool deck. Shower shall be operable.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Provide backflow prevention device on hose bib in pump room. No backflow prevention device.

View this inspection on the county portal ›

Apr 16, 2026 20 demerits · 4 violations
Inspector comments: Inspection conducted with Janeth Martinez. Return line is equipped with 5% flow meters. Both flow meters operational (40 + 50 gpm). Whites powder/chunks which may be chlorine observed in skimmer baskets and on pool floor. Automatic feeder should be used for daily pool chlorine upkeep.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. pH measured below 6.8. Adjust pH to correct range.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2514(c) Pool finish shall be white or light colored. Observed heavy green residue on pool floor/walls. Clean pool. .2537(14) Keep pool surface and pool floor free of debris. Observed tree debris, sand, and stones in bottom of pool. Clean pool.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope was knotted and measured 41’. Requires 44’ of rope. Undo knots and confirm rope is at least 44’.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Exposed metal anchors protruding from pool deck. Remove or secure anchors flush with pool deck.

View this inspection on the county portal ›

Jun 10, 2025 16 demerits · 3 violations
Inspector comments: NO NIGHT SWIMMING. Permit restriction: Both flow meters must remain operational. Combined flow shall not exceed 170 GPM due to drain cover flow restriction.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8 at beginning of inspection. CPO raised pH to 7.2 by end of inspection
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed minor debris on pool floor. CPO started vacuuming during inspection.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope longer than required length. CPO shortened rope to required length.

View this inspection on the county portal ›

May 29, 2025 44 demerits · 9 violations
Inspector comments: For Re-inspection call Main Office at 980-314-1620. Re-inspection fee is required.
#2 · Water quality: disinfectant residual provided by −6
.2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0ppm. Permit denied
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.1. Permit denied
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit with expired reagents. Permit denied
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed skimmer closest to pump room with equalizer line not plugged. PDSC form states all equalizers have been permanently disabled per state recommendations. Permit denied.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum line cover placed on return line. Provide return cover. Permit denied
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed torn ropes on ring buoy. Permit denied
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed small table directly beside pool water edge. Table was relocated.
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
.2543(6) Automatic chemical controllers shall be provided to monitor and adjust disinfectant and pH for interactive play features. Observed chlorine pucks inside skimmers. CPO stated chlorinator is not operating properly. Permit denied.

View this inspection on the county portal ›

Jul 31, 2024 4 demerits · 1 violation
Inspector comments: Mario Robles present for inspection. Observed flow meters operational. Observed compliant body hook and pole. Observed emergency phone with correct # and address per 911 operator. Phone responded when number dialed by REHS. Observed ppm CL and pH compliant.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Replace missing weirs. Missing weir. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Heavy debris in one skimmer basket.

View this inspection on the county portal ›

Jun 27, 2024 18 demerits · 3 violations
Inspector comments: Mario Robles present for inspection. To request a re-inspection, call Mecklenburg County Health Dept at 980-314-1620. Payment of return fee of $100.00 via phone must be made prior to receiving re-inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Measured pH of around 6.0 or less.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Observed no body hook.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. 911 operator has different address from posted address. 911 has address for a cell phone, not the physical address of pool.

View this inspection on the county portal ›

May 23, 2023 4 demerits · 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Clean debris out of skimmers.

View this inspection on the county portal ›

Jul 15, 2022 2 demerits · 1 violation
Inspector comments: No night swimming permitted. CPO on site during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Observed vent not working and no cross ventilation available in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Observed some standing water in pump room.

View this inspection on the county portal ›

Jun 17, 2019 26 demerits · 5 violations
Inspector comments: PDSC reviewed and verified during inspection. CPO present at inspection. No night swimming permitted.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. pH observed at 8.0. CDI. CPO was able to lower pH by the end of the inspection to 7.4.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in shallow side skimmers. CDI. CPO emptied the skimmers.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Lifesaving equipment should be conveniently located. Observed body hook behind large bushes. CDI. Had CPO relocate body hook to a more accessible location.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed ground level windows able to open fully onto pool deck. CDI. CPO placed screws above windows to prevent opening of more than 4 inches.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no signage for address of pool and pool telephone number. Confirmed this information with emergency telephone operator and manager made a sign with information that was placed above emergency telephone.

View this inspection on the county portal ›

Jun 21, 2018 12 demerits · 4 violations
Inspector comments: Gate closest to restrooms/ vending machines must remain locked at all times. spoke to CPO about keeping daily/ weekly records.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Ladder and handrail loose. Tighten both.
#12 · Pool maintenance: inlets and other fittings in place and in good repair −4
Eyeball fitting missing. CDI replaced fitting
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
gate was not self closing. CDI spring added so gate would be self closing.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
No shower before entering pool sign posted. Shower sign must be posted.

View this inspection on the county portal ›

Jun 8, 2017 14 demerits · 3 violations
#3 · Water quality: pool water pH −6
pH at 6.9 No soda ash. Facility issued Immediate Suspension.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed fence catching on ground when swung open; not closing automatically. ITS will be issued if not repaired by the time Im
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed two unfilled holes on deck. Filled.

View this inspection on the county portal ›

Jun 7, 2016 16 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
All weirs missing from skimmers.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Hand rail loose. Tighten
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Gate was not self latching. CDI
#23 · Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 −4
Automatic feeder not functioning. Must have an automatic feeder.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Ventilation fan not working in pump/chemical room.

View this inspection on the county portal ›

Jun 26, 2015 12 demerits · 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Missing one weir iin skimmer (Replace)
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Replace expansion joints in concrete prior to 2016 season. Joints are breaking and cracking.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Chemicals/pump stored in same location.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Post shower sign in public view.

View this inspection on the county portal ›

Jul 16, 2014 12 demerits · 3 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
KEEP POOL FREE OF SUCTION HAZARDS; OBSERVED EQUALIZER COVER MISSING FROM SKIMMER SYSTEM CREATING POTENTIAL SUCTION HAZARD; CDI REPAIR MADE DURIN INSPECTION.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
KEEP SURFACE SKIMMERS IN GOOD REPAIR; OBSERVED SKIMMER BASKET BROKEN IN NEED OF REPLACING.KEEP SURFACES SKIMMER BASKETS CLEAN TO FACILITATE WATER FLOW TO PUMP; OBSERVED SKIMMER BASKET FULL OF DEBRIS IN NEED OF CLEANING.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
KEEP LADDERS IN GOOD REPAIR; OBSERVED LADDER VERY LOOSE COMING OUT OF MOUNTS IN NEED OF FASTENING.

View this inspection on the county portal ›

Jul 15, 2013 18 demerits · 6 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no main drain check recorded. Record daily.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed two skimmer lids cracked. Replace. Observed skimmers with debris. Keep clean.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed step handrail loose. Keep in good repair.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Corrected during inspection.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed pump room floor wet. Keep dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed no soap in men's restroom. Provide soap.

View this inspection on the county portal ›