Jun 8, 2026 12 demerits · 3 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 inch gaps under some sections of fence. CPO covered gaps during inspection. Pool is pre-2010
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed faded phone number and address on sign at emergency phone. CPO re-wrote address and phone number during inspection.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap on backwash pipe.

View this inspection on the county portal ›

Aug 8, 2025 16 demerits · 3 violations
Inspector comments: CPO is Lisandro Gonzalez De Oleo. CPO # is C-092061. Inspection completed with Jasmine Cassell and Edwin Hortado present. Note- replace ring buoy prior to issuance of next years permit. Doors from leasing office are audibly alarmed but not self-closing. These doors must remain locked when the pool is not open for use and/or the leasing office is closed.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy throw rope in poor repair (two pieces of rope tied together to make one piece). CDI- entire rope replaced with new rope.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed 6 inches underneath fencing in some areas. Pool built prior to 2010 therefore no permit action taken. The distance between horizontal fence members should not be less than 30 inches for pools constructed prior to 2010. Observed distance between fencing horizontals at 29 inches. No permit action taken due to age of pool.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed faded signage. CDI- repaired.

View this inspection on the county portal ›

Jun 26, 2024 10 demerits · 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope greater than 29’. CDI: Rope cut to proper length.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed no fan or cross ventilation in pump room.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash.

View this inspection on the county portal ›

May 22, 2024 22 demerits · 4 violations
Inspector comments: Imminent Hazard noted during inspection: Chlorine chemical tabs were in both skimmers underneath of the skimmer baskets. No night swimming. Once all 4 and 6 point demerit items and imminent hazard is corrected, please call 980-314-1620 to pay the $100 re-inspection fee and then call Sr. EHS A. Hall to schedule a re-inspection.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 7.0. pH of pool shall be 7.2 to 7.8. REPEAT VIOLATION
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed ring buoy with ropes around the buoy crumbling when touched.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed gap of 14” under fence to right of front entrance gate.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed phone number posted is incorrect. CDI: Number changed.

View this inspection on the county portal ›

May 18, 2023 6 demerits · 1 violation
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 7.0. PH of pool shall be 7.2 to 7.8. CDI - Operator raise pH to 7.3 before end of inspection.

View this inspection on the county portal ›

Jun 19, 2019 10 demerits · 3 violations
Inspector comments: PDSC form reviewed and verified during inspection. No night swimming permitted. Pool hours 11am-8pm.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Emergency phone had dial tone but would not call out to 911. CDI. Maintenance on site was able to have phone replaced by end of inspection. Phone was re-checked and properly dialed 911.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. No forced or cross ventilation provided.
#26 · Equipment room: valves and pipes identified by color codes or labels −2
.2518(d) Piping and valves shall be labeled with color codes or labels. Pipes not labeled.

View this inspection on the county portal ›

May 30, 2018 0 demerits · 0 violations
Inspector comments: pool has 2 surface skimmers but only 1 aquastar A10RCFR101 PSDC form was sent and updated 5/30/18 to show correct information.

No violations were recorded for this inspection.

View this inspection on the county portal ›

Jul 10, 2017 14 demerits · 3 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed no cap on the vacuum outlet- capped during inspection to correct. This may not be off of the vacuum port unless the vacuum is in use.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose handrail and ladder- tighten.
#22 · Premises: emergency telephone provided −6
Observed the incorrect phone number listed on sign-corrected during inspection.

View this inspection on the county portal ›

Jul 6, 2016 4 demerits · 1 violation
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Maintain daily chlorine and pH readings weekly total alkalinity and cyanuric acid readings.

View this inspection on the county portal ›

Jun 25, 2015 10 demerits · 4 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladder and hand rail. Tighten.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed less than 6 feet of continuous deck space.
#28 · Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted −2
Observed no shower within 300 feet.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed mirrors not shatterproof.

View this inspection on the county portal ›

Jun 4, 2014 22 demerits · 5 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
Observed distance from 3 1/2 ft. marker on deck to 5ft. marker on deck to be 26ft. Observed markers on pool tiles to be 27ft. apart. Both deck and tile markers must be 25ft apart or less. Place additional tile and deck depth markers as needed to comply.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 loose stair handrail. Repair it.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed throw rope to be 36ft instead of 29ft as required. -CDI Rope was shortened to proper length.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed two gaps in fence that are greater than 4" wide.
#22 · Premises: emergency telephone provided −6
Observed emergency phone box non-functional. I.S. issued. Pool is closed. Contact C. Elmore when call box is repaired.

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WENDOVER WALK APARTMENTS” or State ID 2060500581). Inspection type (routine vs. follow-up) is not published in the county's data.