10demerits
WINDSOR GROVE CONDO ASSOCIATION
6134 WINDSOR GATE LANE, Charlotte, NC 28215
Seasonal Swimming Pool · NC permit/State ID 2060500604
Latest result10 demerits
Last inspectedJun 24, 2022
Inspections on record7
On record sinceJun 29, 2015
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
Jun 29, 2015Lower is betterJun 24, 2022
Inspections & violations
Jun 24, 2022 10 demerits · 3 violations
Inspector comments: Night swimming not approved.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope at 34ft corrected to 36ft.
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. No air gap at filter back wash. Corrected during inspection.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Restroom walls in poor condition - detached baseboards, damaged dry wall.
Jul 15, 2021 4 demerits · 1 violation
Inspector comments: Night swimming has not been approved.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
Observed main gate with a gap greater than 4 inches underneath the fencing. This was corrected and the pool operator was able to lower the poles to the fence to decrease the gap.
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present.
Observed gate not properly latching when swinging closed. This was corrected and the pool operator was able to correct the gate to allow it to properly self latch.
Jul 17, 2019 6 demerits · 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Handrail on both set of steps does not extend to within 18" of leading edge
#27 · Equipment room: filter backwash discharged through an air gap −2
no air gap for back wash
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
urinal not working needs to be fixed.
Jul 5, 2018 2 demerits · 1 violation
Inspector comments: *This pool is NOT permitted for night swimming.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restroom mirrors are not shatterproof.
Jun 28, 2017 0 demerits · 0 violations
No violations were recorded for this inspection.
Jul 13, 2016 8 demerits · 2 violations
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
Observed PDSC information to be incorrect. 3 EQ covers are Aquastar 6HP, not 8HP. PDSC corrected. -CDI
#27 · Equipment room: filter backwash discharged through an air gap −2
Observed no air gap at backwash.
Jun 29, 2015 4 demerits · 2 violations
Inspector comments: 17. GENERAL COMMENT -- Loose concrete at steps near condo side
#27 · Equipment room: filter backwash discharged through an air gap −2
No air gap at backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Restrooms dirty, some wall damage.