‹ Back to search

14demerits

WINDWARD AT HOLIDAY HARBOR

19807 HENDERSON RD, Cornelius, NC 28031
Seasonal Swimming Pool · NC permit/State ID 2060500608
Latest result14 demerits
Last inspectedApr 29, 2026
Inspections on record13
On record sinceApr 29, 2014

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

0918 Apr 29, 2014: 18May 14, 2015: 4May 5, 2016: 10May 3, 2017: 10Apr 11, 2018: 14Apr 24, 2019: 18Apr 16, 2020: 14Apr 13, 2021: 12May 5, 2022: 12Apr 11, 2023: 12Apr 9, 2024: 12Apr 24, 2025: 6Apr 29, 2026: 14
Apr 29, 2014Lower is betterApr 29, 2026

Inspections & violations

Apr 29, 2026 14 demerits · 3 violations
Inspector comments: No Night Swimming. Permit Restriction. Flow Meter must remain operable. Flow may not exceed 100gpm due to drain Cover Flow restriction. Suction Hazard.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Debris present in pool from recent weather event. Cleaning in progress. .2537(14) Keep pool surface and pool floor free of debris.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Pool phone number was not posted. Posted during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(h) Provide approved pump in good repair. Pump was set below required 3150 rpm per PDSC approval. Set to 3150 during inspection.

View this inspection on the county portal ›

Apr 24, 2025 6 demerits · 1 violation
Inspector comments: No night swimming. Permit restriction - flow meter must remain operable with flow not to exceed 100gpm due to drain cover flow restriction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope with length of 58’. CDI: CPO shortened rope to 50’.

View this inspection on the county portal ›

Apr 9, 2024 12 demerits · 3 violations
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
depth marker paint beginning to fade, recommend repainting asap. Still readily legible at time of inspection.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
deck chairs observed within 6 feet of pool, moved during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
VFD set at 3100 at time of inspection, PDSC requires 3150 with a flow rate of less than 100gpm. VFD was set at 3150, read 90gpm after backwash at correct setting.

View this inspection on the county portal ›

Apr 11, 2023 12 demerits · 3 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0 at start of inspection. Corrected during inspection to 7.2
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Observed leaves on pool floor.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Observed general cleaning needed to restrooms and fixtures.

View this inspection on the county portal ›

May 5, 2022 12 demerits · 4 violations
Inspector comments: 6. observed equalizer covers to be Aquastar A10 16. observed 2 gates to swing towards pool due to incline and steps 24. observed flow to be 100 gpm, pump set at 3150 rpm
#3 · Water quality: pool water pH −6
pH adjusted to 7.2 during inspection
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
natural cross or continuous forced ventilation required
#27 · Equipment room: filter backwash discharged through an air gap −2
2" air gap required on backwash line
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
mirrors to be of shatterproof construction

View this inspection on the county portal ›

Apr 13, 2021 12 demerits · 3 violations
Inspector comments: 2 gates open toward pool. Steps and topo will not allow gates to swing other direction
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Small amount of debris in pool. Correct during inspection
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. throw rope 5' to long. CPO cut rope to 50'
#27 · Equipment room: filter backwash discharged through an air gap −2
.2513(b) Filter backwash shall be discharged through an air gap. no air gap

View this inspection on the county portal ›

Apr 16, 2020 14 demerits · 4 violations
Inspector comments: *Issuance of a permit by this department does not negate closure required by Executive Order No. 120 or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order. Report was not signed by CPO due to Covid-19 restrictions.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Throw rope > 50'. CDI- Cut to 50' by CPO.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. .2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. observed 2 locked pool gates. locks removed and observed to be self-closing and self-latching. observed 2 gates swinging in toward the pool enclosure.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. No working lights in pump room.
#31 · Dressing and sanitary facilities: sewage disposed of in a properly operating sewage system −2
.2513(b) Overflow and discharges from the swimming pool shall be discharged through a suitable air gap. No air gap at drain.

View this inspection on the county portal ›

Apr 24, 2019 18 demerits · 5 violations
Inspector comments: #16: Gates must be self closing and self latching. Two gates with Master locks where operator has no key to unlock, so gates cannot be opened to check for self closing.
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. pH measured 6.8 upon arrival. CDI- operator brought pH up to 7.2 while on site.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
.2537(14) Keep pool surface and pool floor free of debris. Debris on floor of pool. Cleaning in progress while on site.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed 2 gates prevented from being opened by wrapped cable and master lock. Operator did not have key to master lock; only to gate lock. Cables are removed when pool season is underway. CDI- HOA provided key to master lock; gates were opened and proved to be self-closed and latched. Two gates swing toward the pool, noted previously.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(b) Provide sufficient lighting in pump room. No working lights in pump room.
#31 · Dressing and sanitary facilities: sewage disposed of in a properly operating sewage system −2
.2513(b) Overflow and discharges from the swimming pool shall be discharged through a suitable air gap. No air gap seen.

View this inspection on the county portal ›

Apr 11, 2018 14 demerits · 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed a weir stuck and not operating smoothly.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed two of the three gates opening into facility. One because of the construction of stairs. Both gates opening into the pool are keep locked. The main gate opens out from the pool and has a metal key for access. The fence in the corner by the pump room has foot holds less than 30 inches apart on the outside of the fence.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Lights don't work in the pump/chemical room
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors in restrooms not of shatterproof construction and only cold water is available.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
No visible air gap is present on the backwash line.

View this inspection on the county portal ›

May 3, 2017 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris floating in pool.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed chair impeding deck creating less than 6 ft deck clearance.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water collecting on the pump room floor.

View this inspection on the county portal ›

May 5, 2016 10 demerits · 3 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed bottom of pool collecting debris. Keep pool clean.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed holes in fence exceeding 4 inches. Observed one gate opening into facility exempted by construction of stairs. Recommend moving gate inward and adding fence when fencing is reconstructed again.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Mirrors in restrooms not of shatterproof construction.

View this inspection on the county portal ›

May 14, 2015 4 demerits · 2 violations
Inspector comments: Permit will be available online within 3 days at meckpools@charmeck.org. Post where visible.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
RepIr leak in pump at pipe under filter and flow meter.
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
Repaint floors in restrooms.

View this inspection on the county portal ›

Apr 29, 2014 18 demerits · 6 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed debris on pool floor
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
observed debris in skimmer baskets
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
keep furniture at least 6' from pool and repair the concrete chipping
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
repair the small water leak in the pump room
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
clean the restrooms
#32 · Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean −2
repaint the floors in the restrooms

View this inspection on the county portal ›

Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “WINDWARD AT HOLIDAY HARBOR” or State ID 2060500608). Inspection type (routine vs. follow-up) is not published in the county's data.